45'-3„ <br /> 24 -0 / / <br /> )' 22'-4" ORIGINAL HOUSE WINDOW SCHEDULE: <br /> / 22 -11 ADDITION BY PREVIOUS OWNERS / <br /> (HT.ENERGY CREDIT CALCULATIONS: 36"W x 48"H 60"W x 48"H TAG LOCATION SIZE SILL HT. STYLE TYPE MANUFACTURER U-VALUE SHGC NFRC# <br /> MEDIUM DWELLING UNIT - 3.5 CREDITS r CASE sill@ 32" SL sill@ 32" <br /> t- ` A LIVING ROOM 94"W x52"H 26"H SLIDER ??? ??? 0.22 0.7 TDB-see note #9 <br /> 1C - EFFICIENT BUILDING ENVELOPE <br /> / <br /> PRESCRIPTIVE COMPUANCE BASED ON TABLE R402.1.1 5'_8i" B BEDROOM #1 58"W x 52"H 26"H SLIDER 0.22 0.7 TDB-see note <br /> MODIFIED WITH THE FOLLOWING: <br /> N = . I C BEDROOM #2 60"W x 44"H 36"H SLIDER 0.22 0.7 TDB-see note #9 <br /> VERTICAL FENESTRATION U = 0.22 N I L,J <br /> ROOF R-49 ADVANCED _ $ D KITCHEN 58"W x 34"H 48"H SLIDER 0.22 0.7 TDB-see note #9 ~ <br /> U Q <br /> WALLS R-21 TNT PLUS R-12 G `" `V Q <br /> _ 8 F I I VAULTED CEILING E DINING ROOM 58"W x 46"H 32"H FIXED 0.22 0.7 TDB-see note #9 <br /> FLOOR R 3 <br /> SLAB-ON-GRADE R-10 PERIMETER UNDER ENTIRE SLAB OFFICE 1 SITTING I I OF LIVING ROOM <br /> �s ROOM CLERESTORY H HALF WALL F CLERESTORY 24"W x24"H 80"H& 129"H FIXED 0.22 0.7 TDB-see note #9 Pa <br /> (2) CREDITS = M "- WINDOWS U OPEN TO I G M. BATH CLERESTORY 24"W x24"H 80"H AWNING 0.22 0.7 TDB-see note#9 <br /> 2 24- HIGH EFFICIENCY HVAC EQUIPMENT ABOVE - SEE VAULTED <br /> N I I H M.BED#4&OFFICE 36"W x 48"H 32"H CASEMENT 0.22 0.7 TDB-see note#9 z <br /> 3d STRUCTURAL LIVING ROOM <br /> DUCTLESS SPLIT SYSTEM HEAT PUMPS, ZONE CONTROL "' " 72" 80" � H <br /> - FRAMING cz <br /> ] BEDROOM #3 72"W x 36"H 44"H SLIDER 0.22 0.7 TDB-see note #9 <br /> (1) CREDIT 0 X • <br /> =_ II <br /> ,< I I K SITTING ROOM 60"W x 48"H 32"H SLIDER 0.22 0.7 TDB-see note #9 � ., <br /> 5a - EFFICIENT WATER HEATING CLOSET H L <br /> ALL SHOWERHEAD & KITCHEN FAUCETS - = 'G U <br /> 12T �11" I I ci L LNING ROOM 12"W x 80"H 0"H FIXED 0.22 0.7 TDB-see note #9 V <br /> RATED 1.75 GPM OR LESS "s k, I <br /> ,,,�( S <br /> ° • 13R 07.75" I I l/!�'` ,� NOTES: Q <br /> ALL OTHER LAVATORY FAUCETS 0 <br /> • ALL SD & CO • <br /> I I 1 1. ANY WINDOW OR SIDELIGHT WITHIN 24" HORIZONTALLY OF A DOOR MUST BE TEMPERED - <br /> DETECTORS TO BE 2. ANY WINDOW OR SASH THAT IS 9 SQ. FT. OR MORE AND IS 18" OR LESS FROM A FLOOR MUST BE TEMPERED <br /> RATED 1.0 GPM OR LESS <br /> • <br /> CREDIT �,� BATHROOM INTERCONNECTED CLOSET 'R� � � � r � 3. ANY WINDOW WITHIN A TUB OR SHOWER AREA THAT IS LESS THAN 60" FROM THE FLOOR OF THE TUB MUST BE TEMPERED Z(�5) : DN \ ©� 4. ANY WINDOW ON A STAIRCASE LANDING OR WITHIN 60"OF A STAIRCASE TREAD MUST BE TEMPERED <br /> 8o c 30" X $�" .._/$ �t�b2/��L./2 3!! 7f g " " ;,-) �- ©M 5. CONTRACTOR TO VERIFY ALL GLAZING SIZING AND DOOR DIMENSIONS IN FIELD PRIOR TO ROUGH FRAMING AND <br /> J x - -- - 30 X $� _ \ ORDERING OF GLAZING,WINDOW AND DOOR MATERIALS <br /> r T r / • <br /> - N 36" X SO" ... '� ` 6. ALL GLAZING TO BE'LOW-E', INSULATED GLASS UNLESS NOTED OTHERWISE <br /> LINEN ino 4 �' B7. ALL OPERABLE WINDOWS TO HAVE SCREENS <br /> B ,_f� 8. NEW EGRESS WINDOWS TO MEET REQUIREMENTS PER CODE AS LISTED ON PLANS <br /> A6 �' J IZ�YJ�� � �;� - ' ¢ " A6 9. NFRC CERTIFIED PRODUCTS ARE REQUIRED FOR ALL NEW WINDOWS AND EXTERIOR DOORS �/ <br /> ZZ'/ X 3O 4 / L /C- AC�'.Sf - 30 X8Q_ 1 60C �d- ,, I <br /> W�k A /N 3O'� C�a4ti4til� c., dm <br /> ID • DOOR SCHEDULE: <br /> # NOTE MASTER 3 F TAG LOCATION SIZE COMP. STYLE TYPE MANUFACTURER RATING U-VALUE <br /> p v&L- ,4cc�SS. BATHROOM - N0 I <br /> EGRESS WINDOW BEDROOM 3 ASTE WALK-IN _ __ 1 FRONT ENTRY 36"W x80"H SOLID CORE FLUSH WOOD MILGARD 0.30 J n <br /> o REQUIREMENTS: ' BEDROOM #4 CLOSET N L <br /> - NET CLEAR OPENING . z a o - co3O 2 REAR ENTRY 36"W x80"H SOLID CORE FLUSH WOOD MILGARD 0.30 <br /> AREA 5 S.F. FURR IN OR FRAME WITH I "' Q t " <br /> - NET CLEAR OPENING 2x8FUR TO MAKE FLUSH a cg **WERNER 12-STEP b� _ 0 3 GARAGE TO HOUSE 36"W x80"H SOLID CORE FLUSH WOOD MILGARD 20 MINUTE 0.30 • <br /> n/ <br /> WITH FRONT PORTION ON ADD FIRE ESCAPE ADD FIRE ESCAPE 2 STORY 1200Ibs0 3 2 <br /> HEIGHT OF 24" QD NOTES: <br /> - NET CLEAR OPENING INTERIOR TO ACCOMMODATE LADDER TO ALL LADDER TO All ALUMINUM FIRE 1. CONTRACTOR TO VERIFY ALL GLAZING SIZING AND DOOR DIMENSIONS IN FIELD PRIOR TO ROUGH FRAMING AND <br /> 20" - N ORDERING OF GLAZING,WINDOW AND DOOR MATERIALS - <br /> WIDTH OF TRUSSES BEARING POINTS UPPER BE <br /> DROOMS" UPPER BEDROOMS" ESCAPE LADDER w n <br /> - MAX. SILL HEIGHT 44" 2. ALL GLAZING TO BE'LOW-E', INSULATED GLASS UNLESS NOTED OTHERWISE LU <br /> O 3. ALL OPERABLE WINDOWS TO HAVE SCREENS �-- <br /> 4. GLAZING IN DOORS AND/OR WITHIN 24"OF A DOOR TO BE TEMPERED <br /> ~ I " " L- 5. NEW EXTERIOR DOORS"1 &2"AND THEIR ASSOCIATED LANDINGS FULFILL EGRESS REQUIREMENTS IN R311 �' OCJ <br /> '� -- 72"W x 36"H 36 W x 48 H 36 W x 48 H 6. NFRC CERTIFIED PRODUCTS ARE REQUIRED FOR ALL NEW WINDOWS AND EXTERIOR DOORS <br /> • <br /> 12'-9" SL s11� 44"Qj 4,_3„ CASE sill® 32" 14'-s" CASE slll� 32" 5'-1 6'-4i" w <br /> 24'-O" / // /i // // / <br /> i- PROPOSED UPPER FLOOR PLAN <br /> SCALE: i" = 1'-0" <br /> 0 <br /> 0 • <br /> Q I /� O • • <br /> cNi <br /> Q V/ <br /> 24'-0" 45'-3" / Q Z < <br /> / / <br /> 22'-11" ADDITION BY PREVIOUS OWNERS 22'-4" ORIGINAL HOUSE 1"/ <br /> ,i_ <br /> zLu <br /> _-: i H.- . <br /> W U LLU <br /> I- , <br /> 7 -if - T-- z z co ix <br /> ) Nw <br /> (� <br /> ROOF VENTILATION CALCULATIONS HOUSE: 0 <br /> U <br /> 1 S.F. VENT/300 S.F. AREA <br /> _ _ <br /> 1460 S.F. / 300 - 4.86 S.F. REQUIRED VENTILATION PRE-MANUFACTURED <br /> 50% EAVE VENT VIA BIRD BLOCKING (2.43 S.F.) HALF SCISSOR TRUSSES?? ,I-''' L7 <br /> 0 <br /> 50% RIDGE VENTING (2.43 S.F.) /I" _ PRE-MANUFACTURED _ _ _ ��N <br /> RIDGE VENTING - 0.08 S.F. NET-FREE AREA PER 4' OF RIDGE VENT HALF SCISSOR TRUSSES / r I <br /> 16' OF RIDGE LINES/4 = 18 x 0.08 = 0.32 S.F. <br /> to ROOF LOUVER AIR VENTING - 0.27 S.F. NET-FREE AREA PER AIR VENT <br /> 8 x 0.27 = 2.16 S.F. NET-FREE AREA FROM AIR VENTS <br /> VENTED BIRD BLOCKING - 0.0218 NET-FREE AREA PER 2" HOLE X <br /> (4) HOLES PER BLOCK = 0.0872 PER 24" BLOCK c 3f^ 2My� <br /> 768" APPLICABLE EAVE LENGTH/24" = 32 <br /> 32 x 0.0872 = 2.79 S.F. NET-FREE AREA 0 EAVES <br /> • <br /> Q� <br /> • <br /> J <br /> LI -I ♦ W CLQ Ln <br /> _C I <br /> Q N +> In <br /> L Q Li) <br /> Ri ai <br /> \1.--1 <br /> `D <br /> \ - r \ 1 <br /> B a Do z `-' <br /> B A6 d- >- - • <br /> A6 I 13 z J M " <br /> /I, _ - - - - _ PRE-MANUFACTURED _ - _ Q <br /> STANDARD TRUSSES bo Q <br /> x <br /> DATE <br /> a 7 / 5 / 2019 • <br /> � <br /> z c <br /> SCALE <br /> L iJ 1 „ _ 1 , _ � „ <br /> - r , 4 .‘ <br /> L <br /> " 4'-3" 14'-9" 5'-1 " 6'_4 » CITY OF EVERETT <br /> I 23 -0 12 s // // REVIEWED FOR PERMIT SHEET : <br /> r- PROPOSED ROOF PLAN 0 I <br /> .. <br /> ` SCALE: i" = 1'-0" \L R T H <br /> 1 <br />