Laserfiche WebLink
0 <br />w <br />I <br />00 <br />DO <br />cV <br />r7 <br />4'-2- (4) 3/4" Die. Lift Inserts <br />w/ U.V. Caps <br />,,,, NOTE: PROVIDE WITH NON -SUP LIDS. <br />................. . <br />rrrrrrrrrrrrrrrrJr`l <br />,,,,,, rr rrr rr rrr rrr <br />rrrrrrr/,,,,rrrrrrr <br />rrrr/rrrrrrr/,,rrrr <br />.................... <br />r ,rrrrrrrrrrrrrrrrr <br />.................... <br />rrrrrrrrrr/,rrrr/rr <br />.................... <br />rrrrrrrrrrr/r/,rrrr <br />................. <br />N 00 <br />rrrrrrrrrrrrrrrrr as � I I <br />rrrrrrrrrrrrrrrrr <br />,rrrr, ,rrrr/rrrrrrr <br />.................... <br />.................... <br />aoo <br />PLAN SYMBOLS <br />Spring Assisted <br />^ • ' Galvanized Diamond Plate Cover ....... <br />w Locking Latch <br />_ Galvanized "C' Channel, S-0- Lg. 4 3f4' Die. Knockout 1 1 2" Die. Lift Hole <br />1 Each Side, 4 Sides 8 Each Side, 4 Sides 1 Each Side, 2 Sides <br />00 <br />to <br />Inn <br />N <br />Die. Sump <br />p .. <br />2 V2' Dia. Ground Rod Knockout <br />2 laces In FLoor 8" 7» 2'-2» 7• <br />l <br />PullOptionaing Iron <br />1 Each Comer, <br />4 Comers SECTION AA END VIEW <br />Typical All Sides <br />'WR./ELECT./COMM. PULL VAULT <br />OLDCASTLE 504-LA <br />t1" <br />COVER <br />No. 612-TL-42C <br />7,000 Ibs <br />PROVIDE COVER THAT <br />CORRESPONDS WITH <br />PLAN SYMBOL (SHOWN <br />RIGHT) <br />VAULT <br />No. 612 <br />9,000 Ibs <br />BASE <br />No. 612-SB <br />10,500 Ibs <br />m\ ` 42" Dio. Access <br />0 <br />V-6" <br />a <br />•O / <br />O.' 00 <br />12'-0" <br />5'-0" <br />6 1 / <br />V-6„ <br />D <br />s R <br />d.. <br />12'-8" \ <br />\ <br />\ 6'-8" <br />NOTE: PROVIDE WITH NON -SLIP LIDS. <br />INDICATES PUD <br />CLEAR ZONE <br />o <br />I I <br />II SW <br />PLAN SYMBOL <br />LOCKING STEEL COVER WITH PADMOUNT <br />Snohomish County P.U.D. Standard <br />SnoPUD Cat ID #742202 <br />6,700 Ibs. <br />�o PUD PV <br />C➢� OPJ PLAN SYMBOL <br />LOCKING STEEL COVERS <br />No. 612-TL-3-332P <br />SnoPUD Cat ID #782252 <br />7.400 Ibs. <br />SNOPUD VAULT -SWITCH &PULLING VAULT <br />SEE PUD REFERENCE DRAWINGS <br />GENERAL NOTES <br />1. IMPORTANT - PLAN SYMBOLS: PROVIDE BOXES AND VAULTS SHOWN <br />ON THIS SHEET AND SHEET E3.02 WHERE INDICATED ON PLANS. <br />PLAN SYMBOLS ON DETAIL SHEETS ARE NOT TO SCALE; PLAN <br />SYMBOLS ON PLANS ARE TO SCALE. FOR SIMILAR PLAN SYMBOLS, <br />PROVIDE BOXES AND VAULTS THAT MATCH THE (SCALED) LENGTH <br />AND WIDTH SHOWN ON THE PLANS. <br />2. PROVIDE ADDITIONAL (SUPPLEMENTAL) VAULTS, BOXES, AND/OR <br />HANDHOLES, AS NECESSARY FOR COMPLIANCE WITH CODE AND <br />UTILITY COMPANY STANDARDS. <br />0 <br />-� NOTE: PROVIDE WITH NON -SLIP UDS. <br />(A �C�� �� � Full 180' Open <br />LLJ�y _ NOTE: PROVIDE WITH NON -SLIP LIDS. NOTE: PROVIDE WITH NON -SLIP UDS. <br />�� `� sted <br />Galvanized IDiamond Plate Doors \ \ <br />w-> 5 T i i i!T i 1 w/Locking Latch <br />(nOptional\\ \ \ \ <br />---- -- -NonSli Doors <br />G . i, ii rTjT1T!p!7!T1T1Ty!7! ii- P '-oil 6'-0i. <br />District Cat ID 766313 6, <br />w i iT 71Ti -!T i!T!T!T!T! illSli l - <br />\ Full 180. Open <br />COVER with P <br />ADJUSTABLE FRAME <br />0 <br />No. 35P ASSEMBLY ' $�TiiiT7!T!TTI; r srr rlrl,iT - lr! !T!T- < \ \ ri-ri-ilrr�-� � ! ! _ �- 1r7= _y. l�t1T-�-T =�- <br />1,12, r-,�71i!T_l,i,l1 <br />272 Ibs. ! !1 ' ' ' ri' 1T'i1T itr \ \ / / 1 15 1 2" <br />�i �� \ \ / /_ I- -I-I- <br />LO -i - �-!-'T !r!T!T!-!T!T!T!-� \ / I-I-I-1-I-I-1-I- / " iTl71y.�.,_,i1jiT,�/- G Die. Bronze �' \ \ /_ I -I -I -I -I -I -I -I -I -I -I _ <br />�.�-!-,�- 40 � \ / 21 1 2 <br />_i �!li,lTlTISI, l�,lT� Grounding Insert (- <br />Suitable for use in off-street locations-li!l�l!1is,_,_,_,S,i�_ (1 Each Side) <br />h densit <br />where not subjected to hi traffic. \ -I-I-I-I-I-I-I-I-1-I-I-I-I-I-I-I-I- <br />Q J 9 Y CoverI- <br />�-i-i-i-�- <br />NO. 3030-P <br />EMBEDDED 1 ' x 3' I--I-I-I-I-1-I-1-I-I-I-I-I-I-I- I- LLLLLLL <br />U � Dia. Plated Insert <br />„-I-I-I-I-i--I-1-I-I-I- <br />11D IbS. °1 I —I— I —I LLLLLLLLLLLLLL <br />Grounded) I —I —I —I 1-1-1—I- <br />2 BARE SD CU LLLLLLLLLLLLLLLLLL <br />O 4,_9J„ LLL <br />(2 Each Side) # BRONZE PLATE <br />SOLID OR STRANDED LLLLLLLLLLLLLLLL <br />1j" Die. Lift Hole 2'-1O" LLLLLLLLLLLLLLLLL 15„ <br />J 3 -6 LLLLLLLLLLLLLLLL <br />(1 Each Side) e Q 2' .4" LLLL LLLLLLLLL <br />LLLLLL <br />F- PRIMARY CONDUIT m ® Optional Solid Base `tLLLLLLL <br />d LLLL <br />BASE 4'-10}" TEEL <br />m sso Ib030-SB 1'-11" a <br />Of No. 35-PB-B-FRT �/ m <br />3 6,090 lbs. J COVER <br />INDICATES PUD \ T �I <br />o' : 4'-8" CLEAR ZONE <br />4'-8" y.. <br />(10 <br />v <br />I n MIN. ONE 5/8" x 8' <br />J" Die. Plastic Insert Q „ COPPER CLAD PRECAST <br />C�1 (2 Each Side)._ o: \ } Die. Plated Insert 2'-6" 2'-6' PLAN SYMBOL <br />(1 Each Side) � GROUND ROD CONCRETE <br />N 2" Die. o:'e: \ SECONDARY INTERIOR DIMENSIONS <br />O Sump a: 5" x 32" Knockout TWO RODS REQUIRED CONDUIT <br />IF LAST VAULT. „ Lri 5'-8" \���\ (2 Each Side, 2 Each End) SIZES OF TRANSFORMER 18 3 4 L x 12 3 4 W <br />p 3'-8" REFER TO 4.N.2. AND VAULTS. OBTAIN FINAL DID / / <br />�� Galvanized PullAift Iron PLAN SYMBOL SIZES FROM SNOPUD PRIOR TO <br />Y (1 Each End) SUBMITTAL REVIEW. <br />cn PLAN sYMBOL PLAN SYMBOL <br />Q <br />w <br />U <br />Q <br />J <br />z 3 TELEPHONE PULL VAULT - FRONTIER 3x5 4 75-500KVA TRANSFORMER VAULT 5 ELECTRICAL PULL BOX - 3030-LA HANDHOLE TYPICAL <br />s <br />of <br />EX.XLL_ <br />X TYP. �P- <br />TYP. <br />Of <br />w <br />Q <br />3 <br />a IF THIS DRAWING IS NOT 22''x34" SCALE ACCORDINGLY. 100% DESIGN - ISSUED FOR PERMIT REVIEW - NOT FOR CONSTRUCTION <br />PROJECT ENGINEER: SCALE: DWG. NO. <br />II © ® PND ENGINEERS, INC. IS NOT RESPONSIBLE FOR SAFETY E. DAVID NOTED PORT OF EVERETT <br />E3 00 <br />��,, PROGRAMS, METHODS OR PROCEDURES OF OPERATION, OR THE • <br />04 <br />CONSTRUCTION OF THE DESIGN SHOWN ON THESE DRAWINGS, DESIGNED BY: DATE: WATERFRONT PLACE CENTRAL <br />o r WHERE SPECIFICATIONS ARE GENERAL OR NOT CALLED OUT, E. DAVID MAR. 2018 <br />O1 �f ENGINEERS, INC. - _ <br />� HRRBOR POWER THE SPECIFICATIONS SHALL CONFORM TO STANDARDS OF CIP N0. 6-8-002-01, 6-8-002-02, <br />W EVERETT E a ' N E E R 5, ' N C. SE MILLWRIGHT LOOP AND OPEN SPACES $—°02-03, & $—°02-04 <br />1736 Fourth Avenue S. Suite A INDUSTRY. DRAWINGS ARE FOR USE ON THIS PROJECT ONLY DRAWN BY: CHECKED BY: <br />p P.O. BOX 538 Seattle, Washington 98134 AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN K. DAVIS E. DAVID BOX <br />PROJECT <br />a EVERETT, WA 98206 P: 206-624-1387 PM: ED DAVID, PE TEL: 206.855.4600 0 - - - - 100% PERMIT SET APPROVAL FROM PND. DRAWINGS ARE ALSO NOT TO BE USED PULL & No. PD-WP-2018-02 <br />(425) 259-3164 IN ANY MANNER THAT WOULD CONSTITUTE A DETRIMENT APPROVED BY: <br />www.pndengineers.com DIRECTLY OR INDIRECTLY TO PND. <br />NO. DATE BY REVISION VAULT DETAILS SHEET NO. 82 OF 83 <br />G1 f Y OF EVERETT <br />REVIEWED Fop AI=Rnnlr <br />