My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1528 GRAND AVE Geotech Report 2022-10-25
>
Address Records
>
GRAND AVE
>
1528
>
Geotech Report
>
1528 GRAND AVE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 2:02:41 PM
Creation date
4/1/2022 2:19:49 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
1528
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GeoTest Services, Inc. Report Date 7/17/2019 <br /> Anderson Residence- Everett, Washington GTS Project No.19-0384 <br /> conditions. Nonyielding walls under drained conditions should be designed for an <br /> equivalent fluid density of 55 pcf,for structural fill in at-rest conditions. Design of walls <br /> should include appropriate lateral pressures caused by surcharge loads located within <br /> a horizontal distance equal to or less than the height of the wall. For uniform <br /> surcharge pressures, a uniformly distributed lateral pressure equal to 35 percent and <br /> 50 percent of the vertical surcharge pressure should be added to the lateral soil <br /> pressures for yielding and nonyielding walls, respectively. <br /> For structures designed using the seismic design provisions of the 2015 International <br /> Building Code, GTS recommends that retaining walls include a seismic surcharge in <br /> addition to the equivalent fluid densities presented above. We recommend that a <br /> seismic surcharge of approximately 12H (where H is the height of the wall in feet) be <br /> used for design purposes. <br /> Passive earth pressures developed against the sides of building foundations, in <br /> conjunction with friction developed between the base of the footings and the <br /> supporting subgrade, will resist lateral loads transmitted from the structure to its <br /> foundation. For design purposes,the passive resistance of well-compacted fill placed <br /> against the sides of foundations is equivalent to a fluid with a density of 250 pounds <br /> per cubic ft. The recommended value includes a safety factor of about 1.5 and is based <br /> on the assumption that the ground surface adjacent to the structure is level in the <br /> direction of movement for a distance equal to or greater than twice the embedment <br /> depth. The recommended value also assumes drained conditions that will prevent <br /> the buildup of hydrostatic pressure in the compacted fill. Retaining walls should <br /> include a drain system constructed in general accordance with the recommendations <br /> presented in the Foundation and Site Drainage section of this report. In design <br /> computations,the upper 12 inches of passive resistance should be neglected if the soil <br /> is not covered by floor slabs or pavement. If future plans call for the removal of the soil <br /> providing resistance,the passive resistance should not be considered. <br /> An allowable coefficient of base friction of 0.35,applied to vertical dead loads only, may <br /> be used between the underlying imported granular structural fill and the base of the <br /> footing. If passive and frictional resistance are considered together, one half the <br /> recommended passive soil resistance value should be used since larger strains are <br /> required to mobilize the passive soil resistance as compared to frictional resistance. A <br /> safety factor of about 1.5 is included in the base friction design value. GeoTest does <br /> not recommend increasing the coefficient of friction to resist seismic or wind loads. <br /> 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.