Laserfiche WebLink
A I B I C I D I E I F I G A H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> ' , , 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> itit !' , ' '• - a _ _ � DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> �' x --� ENERGIZED IN THE OPEN POSITION, A -� <br /> ;t-,,; THE DESIGNER OF ANY DISCREPANCIES <br /> - ,� SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> r '.i` THE HAZARDS. (PER ART. <br /> � ,�� '" �.-. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> . . ' 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> '4,4' '.-. THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION,WHICH <br /> ; , BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. — <br /> 1, _,- _ I'u,, (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> 44 t fin 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> :* LABORATORY SHALL LIST ALL OF WORK. <br /> `j!.,:,' ,,,:11.,,,: EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> .0- ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> N 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> i 3` ,. STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> :: INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> e 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> I'' AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> _ ' _ t BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> 1 OIL J x r*ii UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. — <br /> ' 6. MODULE FRAMES, RAIL, AND POSTS <br /> :. ? .: _11 1s 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> `. SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> ---- .__.. _.h__ �,. GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> ,f j 3--', .e AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> ., ",, - " _ . ` ,.„ 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. <br /> w <br /> CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO <br /> ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> t" - 9. ALL ELECTRICAL WORK TO BE IN <br /> t,"? ����10R sONFS COMPLIANCE WITH THE NATIONAL <br /> ' •� ��oF\NAy%� ELECTRIC CODE (NEC). — <br /> J , - <br /> 'a 201148.8 Q <br /> • <br /> ASS/ONALE � <br /> 11/11/2020 <br /> STRUCTURAL ONLY <br /> a SHEET INDEX_ <br /> it i ' 1.l :- PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> �, PV 2 SITE PLAN PV 6 PLACARD <br /> '"' `° Y _.._-- PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> - PV 4 CHIKO MOUNTING <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED KAM CUSTOM <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Georgia Hallett DATE: <br /> DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> Arl SOLGEN ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 11/10/2020 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 993011 <br /> THE RECIPIENT'S ORGANIZATION, EXCEPT IN <br /> POWER CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 211 Barbara LN. , Everett, WA 98203 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN P\/ 1 <br /> CONSENT FROM SOLGEN POWER. <br />