Laserfiche WebLink
3art <br /> * FOUNDATION NOTES <br /> r. PROPERTY LINE <br /> \ 72'-0"* 1. VERIFY ALL DIMENSIONS ON SITE. 10.FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE as«'T va,CU�*'i <br /> PARCEL NO. 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM ATTACHMENT LOCATIONS ARE B"THICK MINIMUM WITH 3'-0"HEIGHT <br /> LOT SIZE: 00471700003501 - WALL PER R&R LEVEL (MEASURED FROM B/FTG TO T/CONC)MINIMUM. •p .�j,� , <br /> 0.22 ACRE(S)(9,583 SOFT) SURVEY. 11.PARCEL DIMENSIONS PROVIDED BY KING COUNTY.NOT TO SCALE. S s <br /> 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK, '•Oypi <br /> LEGAL DESCRIPTION HELICAL PILES 1/SD-I.1 )APPROXIMATED PER SNOHOMMISH COUNTY IMAP AND SEATTLE <br /> BUILDING LOT COVERAGE: HIGHLAND ACRES BLK 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED AUGUST 15, DEPARTMENT OF CONSTRUCTION AND INSPECTIONS GIS MAPPING TOOLS. <br /> 16%(1,564 SQFT) 000 D-01 -N 75FT OF S 2021,FOR ADDITIONAL INFORMATION,SPECIFICATIONS,AND NOT TO BE USED FOR LEGAL PURPOSES. <br /> 150FT OF LOT 35 LESS REQUIREMENTS. 12.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS <br /> PTNTO CITY OF 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED JULY 23,2021.REFER TO NOT SHOWN FOR CLARITY. <br /> EVERETT PER WD VOL STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND 14.PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'-0"OR <br /> 618 PG 104 ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. UNTIL REFUSAL,WHICHEVER IS <br /> _ 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8'. SHALLOWER. <br /> OWNER NAME& 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH± <br /> ADDRESS 0'-6"TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS HELICAL PILE REFUSAL CRITERIA: <br /> ALOES KIMBERLY ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC <br /> ADJACENT SPANS EXCEED THE SPACING LIMITATION OF 8'-0"O.C.MAXIMUM. PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL <br /> 5811 BEVERLY LN, 8. IF REQUIRED,ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO. Q O <br /> EVERETT,WA 98203 PILE AND EXTEND MIN 6"PAST SUPPORTING PILE EA END. ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE 0 y <br /> q 9. IF REQUIRED,ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE BEGINS TO EXPERIENCE UPLIFT FLEXURE. F M <br /> FOUNDATION WITH 5B"DIAM.SIMPSON TITEN HD SCREW ANCHORS(OR - - - - - - -_- H Z a <br /> APPROVED EQUIVALENT)AT A MAXIMUM SPACING 12"OC WITH A 4" _ a <br /> MINIMUM EMBED.ANCHORS TO BE CENTERED ON OR INSTALLED ABOVE 2(R . <br /> THE CENTER LINE OF THE CHANNEL. Z W'z <br /> PILE SPACING&LOADREQUIRMENTSTABLE FOUNDATION LEGEND O o <br /> PILE MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD.kips <br /> PILE ft TYPE STWN END ALLOWABLE LOADING 200%MIN VERTICAL CAPACITY LOCATION ri EXISTING RESIDENCE STRUCTURE <br /> PILES OFFSET (MIN ULTIMATE CAPACITY) -- <br /> Typical HELICAL 8'dt'UNO 3'-O'UNO 11.Okip 22.0kip TYP : EXISTING ADJACENT STRUCTURE ',\ <br /> NOTES: --: AREA OF PROPOSED WORK <br /> a.MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE ---- PROPERTY LINE <br /> 5'f"'— ' 57'-0"• f--9'-6"* MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED <br /> r(2)PILES Qa 8'-0"O.C.MAX AREA OF WORK THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM INSTALLATION * APPROXIMATE DIMENSION <br /> TORQUE RATING OF 8,300FT•LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL THICKNESS PER / <br /> ESR-3750. '¢' HELICAL PILES <br /> 3 4'. 4 b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" <br /> \ TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. - ' <br /> w A •o c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. <br /> 2 -Y d.CONCENTRIC DRIVEN PILES AS MANUFACTURED BY STABIL-LOC SYSTEMS,LLC,IN ACCORDANCE WITH ESR-4121. <br /> -' * O e. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF <br /> 4 m THE ASSEMBLY. <br /> b i f. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. <br /> W0. Cf (U ' ¢!� LOCATE PILE -C <br /> M <br /> • WITNIN.2FT MAX ' <br /> 0 OF CORNER i - * r I <br /> rt a ! (E)RESIDENCE Z m <br /> 5811 Beverly Lane,Everett, <br /> wL ---------. '' WA,98203 • <br /> J (E)S'CONCPEfE STEM- <br /> g wALtr-rTALLMINTYPAT !? { (El RESIDENCE <br /> ir.i005FYLNOPRIORTO 5815 Beverly I ane,Everett. <br /> AT RKEPc0BcneEWALL <br /> AT PILE LocATN)NSIS WA,982C3 -. <br /> LESS THAN*rTALL 5811 Beverly Lane, <br /> LEVEL SURVEY Everett,WA,98203 <br /> -I a<� Access{2}PILES @ 6 557 O C.MAX , <br /> U.f <br /> 1 318' 5/4 1/2 -1/S 5/8 <br /> -4- _ + S210 <br /> 803-2XR <br /> d , LOCATEPLE. I F„i - WITHIN 2FT MAX;: ' <br /> /--12'-5", / 2D'"5", y 6 /4 OF CORNER - - : NJ <br /> .._ .. .. <br /> cO <br /> w $ - MRT <br /> a <br /> m a- - -112 4-I/2 in <br /> o - --,- - <br /> 8/15/21 <br /> W <br /> i <br /> ' .4 0 2415, -1(4 O <br /> ET- , <br /> 12:5 f <br /> 20.5' <br /> kalion " <br /> 5' =13 Heliee Pile •N <br /> 'i. 72'-0"* r4Z R&R LEVEL SURVEY <br /> �1."" 24' <br /> PROPERTY LINE <br /> Beverly Ln jilr. SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL REQUIREMENTS <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN a 1..\ <br /> W <br /> ch 4 <br /> co <br />