My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8215 BROADWAY CROWN CASTLE ANTENNA 2022-04-04
>
Address Records
>
BROADWAY
>
8215
>
CROWN CASTLE ANTENNA
>
8215 BROADWAY CROWN CASTLE ANTENNA 2022-04-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2022 11:49:45 AM
Creation date
4/4/2022 11:48:50 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8215
Tenant Name
CROWN CASTLE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br /> I 1. ALL NEW CONDUCTORS TO BE INSTALLED SHALL BE COPPER. <br /> ALL CONDUCTORS SHALL BE THHW, THWN, THWN-2, XHHW,OR XHHW- UNLESS NOTED OTHERWISE. Tii ■ 0 Mobile A . • <br /> 2. CONTRACTOR IS TO HELD VERIFY ALL EXISTING ITEMS SHOWN <br /> ON THE ELECTRICAL ONE-LINE DIAGRAM AND NOTIFY THE <br /> ENGINEER OF ANY DISCREPANCIES. <br /> 3. ALL GROUNDING AND BONDING PER THE NEC 250. 8960 ALDERWOOD ROAD <br /> PORTLAND,OR 9722Q <br /> 4. GENERAL CONTRACTOR SHALL PROVIDE LABELING ACCORDING <br /> TO NEC 110.21. <br /> CROWN <br /> CASTLE <br /> 1505 WESTLAKE AVENUE NORTH,SUITE 800 <br /> SEATTLE,WA 98109 <br /> 11 <br /> /— —1 (TE)RANS UTILITYFORMER COMPANY B+T G ER P <br /> 1717 L_ _J SUITE BOULDER <br /> SUITE 300 <br /> TULSA,OK 74119 <br /> (E) WIRE AND CONDUIT PH:(918)587-4630 <br /> PER UTILITY COMPANY REQUIREMENTS www.btgrp.com <br /> r — — (E) METER ENCLOSURE <br /> FINAL PANEL SCHEDULE <br /> LOAD POLES AMPS BUS AMPS POLES LOAD L - - T-MOBILE <br /> L1 L2 L3 A <br /> (E) WIRE AND CONDUIT SITE NUMBER: E01 A <br /> r - - BU#: 824022 <br /> I I FEELY <br /> o J o / a N DOLE, NEMA ESCON ECT. LOCATION OF 3MAIN <br /> I <br /> BorDINc JUMPER. <br /> 8215 BROADWAY <br /> L — _ _I BONDING <br /> WA 98203 <br /> EXISTING <br /> O (E) WIRE AND CONDUIT 60r-0°MONOPOLE <br /> RATED VOLTAGE:0120/240 0 . 3 PHASE, 4 WIRE BRANCH POLES:012 024 030 042 APPROVED MF'RS <br /> RATED AMPS: 0100 0225 0400 0 . CABINET: ❑SURFACE ❑FLUSH NEMA 01 03R 04X <br /> ❑MAIN LUGS ONLYIMAIN AMPS ❑BREAKER ❑FUSED SWITCH ❑HINGED DOOR ❑KEYED DOOR LATCH (E) 200A, 120/240V, 1463W, NEMA 3R, POWER PROTECTION <br /> ❑FUSED ❑CIRCUIT BREAKER BRANCH DEVICES ❑ TO BE GFCI BREAKERS FULL NEUTRAL BUS GROUND BAR - - ��CABINET (PPC) WITH INTEGRATED MANUAL TRANSFER SWITCH, <br /> ALL BREAKERS MUST BE RATED TO INTERRUPT A SHORT CIRCUIT ISC OF 10,000 AMPS SYMMETRICAL r ✓✓✓ LOAD CENTER, AND FACTORY WIRED GENERATOR INTERFACE FOR <br /> INSTALL A NEW 2P 200A BREAKER E, PORTABLE GENERATOR CONNECTION ISSUED FOR: <br /> • <br /> INSTALL A NEW 1P 20A BREAKER I REV DATE. DAWN DESCRIP IlON DES./QA <br /> INSTALL NEW WIRING FOR NEW HPL3 CABINET WITH (3) 3/0 AWG THWN (COPPER) AND (1) #2G AWG. MINIMUM CONDUIT SIZE TO BE 2". <br /> IF MAIN DISCONNECT CIRCUIT BREAKER IS LESS THAN 150A. REPLACE WITH 2P 200A BREAKER RATED FOR 120/240V. l 1 I A G/3/21 AN PRELIMINARY REVIEW ITS <br /> IF 200A BREAKER WILL NOT PROPERLY FIT IN EXISTING PANEL, REPLACE (E) PANEL WITH SQUARE D PANEL Q012040M20ORB (OR APPROVED EQUAL). 0 7/9/21 YXI CONSTRUCTION YXI <br /> UPGRADE FEEDER WIRES TO MEET AMPACITY IF NEW PANEL IS REQUIRED. . .. <br /> FINAL PANEL DESIGN AND CALCULATIONS FOR WIRE SIZE WERE BASED OFF OF EXISTING DOCUMENTS AND PHOTOS 1 8/11/21 LHT CONSTRUCTION YXI <br /> INSTALL NEW 20A, 1-POLE <br /> BREAKER IN PPC FOR GFCI <br /> INSTALL NEW 200A, 2-POLE <br /> 20/1 BREAKER IN PPC `-' <br /> INSTALL NEW (3) 3/0 CU <br /> -200/2 WITH #2 GROUND IN 2"PVC <br /> L J <br /> RGS FOR DC CABLES co WAS 47< <br /> — — 0.., �. <br /> 100 <br /> NEW HPL3 I I NEW LB3 <br /> 1i <br /> CABINET I CABINET F}T <br /> 3,1 <br /> . J — — — — J L — — — — J <br /> ' <br /> B&T ENGINEERING, INC. <br /> 3425 <br /> Expires 12/31/21 <br /> IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> 1 OF A LICENSED PROFESSIONAL ENGINEER, <br /> TO ALTER THIS DOCUMENT. <br /> SHEET NUMBER: • REVISION: <br /> OAC PANEL DETAIL ONE LINE DIAGRAM ■ t <br /> SCALE: NOT TO SCALE }SCALE: NOT TO SCALE ,H1J 1 <br /> 1SI \a <br />
The URL can be used to link to this page
Your browser does not support the video tag.