My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3822 COLBY AVE DR KANG DDS 2022-04-04
>
Address Records
>
COLBY AVE
>
3822
>
DR KANG DDS
>
3822 COLBY AVE DR KANG DDS 2022-04-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2022 2:36:30 PM
Creation date
4/4/2022 2:35:42 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3822
Tenant Name
DR KANG DDS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> FORTE • <br /> MEMBER REPORT PASSED <br /> Roof, BM1-Roof: Drop Beam <br /> 1 piece(s)5 1/8"x 13 1/2"24F-V4 DF Glulam <br /> Overall Length:9'3' <br /> 0 0 <br /> Ii <br /> 4, 8'6" 4, <br /> Il <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Roof <br /> Member Reaction(Ibs) 4273 @ 2" 11211(3.50") Passed(38%) -- 1.0 D+1.0 S(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 3250 @ 7'8" 14057 Passed(23%) 1.15 1.0 D+1.0 S(All Spans) Building Code:IBC 2015 <br /> Pos Moment(Ft-Ibs) 9755 @ 4'8 1/16" 35805 Passed(270/0) 1.15 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Live Load Deft(in) 0.035 @ 4'6 7/16" 0.438 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) Member Pitch:0/12 <br /> Total Load Defl.(in) 0.071 @ 4'6 7/8" 0.583 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) <br /> • Deflection criteria:LL(L/240)and TL(L/180). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 9'3"o/c based on loads applied,unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 9'3"o/c based on loads applied,unless detailed otherwise. <br /> •Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L=8'9". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified giulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Snow Total Accessories <br /> 1-Stud wall-DF 3.50" 3.50" 1.50" 2002 2271 4273 Blocking <br /> 2-Column Cap-steel 5.50" 5.50" 1.50" 2443 2354 4797 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Dead Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 9'3" N/A 16.8• <br /> -- <br /> 1-Uniform(PSF) 0 to 9'3"(Front) 20' 17.0 25.0 Default Load <br /> 2-Uniform(PLF) 3'6"to 8'6"(Top) N/A 229.0 - <br /> Weyerhaeuser Notes _ <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by BJM <br /> • <br /> 11� <br /> ForteWEB Software Operator Job Notes 5/28/2020 9:59:47 PM UTC <br /> Benjamin J.McCann <br /> CT Engineering Inc. ForteWEB v2.4,Engine:V8.0.1.5,Data:V7.3.2.0 <br /> (206)265 4512 <br /> File Name: 20064-DR RTU <br /> bmccann@ctentengineering.com Weyerhaeuser Kang <br /> Page 2/9 <br />