Laserfiche WebLink
1.0 INTRODUCTION AND NOTICES <br /> For this project, HBI is the ground improvement design-build contractor and the ground improvement <br /> design engineer. In this capacity, HBI performed this evaluation in a manner consistent with the standard <br /> of care ordinarily exercised by members of the geotechnical engineering community currently practicing in <br /> the area. SeaLevel Properties is the Owner and the General Contractor ("Contractor") is Graham <br /> Construction. HBI is contracted with Tiscareno Associates for the design and it is our understanding that <br /> HBI will be contracted with Graham Construction for the construction of our design. Although there are <br /> expected to be other consultants and contractors working on this project,none have authority over HBI. <br /> Any designs prepared and furnished by HBI, including any designs, means, and/or methods(collectively, <br /> "Designs"),have been prepared based upon, and in anticipation of,HBI performing the work called for in <br /> such Designs. As such, the Designs are specifically tailored for HBI's purposes and have been prepared <br /> for exclusive use by HBI. Owner and/or Contractor shall not use or control the Designs without the prior <br /> written consent of an authorized representative of HBI, and then only as absolutely necessary to perform <br /> such permitted use.The Designs are subject to protection under the Copyright Act of 1976 and Architectural <br /> Works Copyright Protection Act of 1990. Owner and/or Contractor shall not copy, reproduce, emulate or <br /> model the Designs or disclose, publish, or disseminate the Designs to any third parties without the prior <br /> written approval of an authorized representative of HBI. HBI is and shall continue to be the sole owner of <br /> the Designs. <br /> Owner and/or Contractor shall not permit other contractors to use the Designs on this Project or use the <br /> Designs on other projects without the prior written approval of an authorized representative of HBI. HBI <br /> makes no warranties or guarantees as to the suitability of the Designs for use by others or for other <br /> applications or projects.Any such use shall be at Owner and/or Contractor's sole risk,and the Owner and/or <br /> Contractor shall indemnify, defend, insure, and hold harmless HBI, its agents, consultants, officers, <br /> directors and employees from and against any and all claims,damages,losses,costs and expenses,including <br /> but not limited to attorney's fees,costs and expenses,arising out of or resulting from use of the Designs by <br /> any party other than HBI. <br /> 2.0 BASIS OF DESIGN <br /> This design is based on HBI's understanding of the project. Our understanding of the project is based on <br /> our review of the following documents and performance requirements articulated by the project structural <br /> engineer and geotechnical engineer. <br /> 2.1 Reference Documents <br /> Although many documents were reviewed,only those which provided information that directly affects our <br /> design are listed below. <br /> • Waterfront Place Apartments — Ground Improvement Basis of Design, memorandum <br /> prepared by GeoEngineers,dated January 23,2017. ("BOD Memo") <br /> • Geotechnical Engineering Services, Waterfront Place Apartments, Everett Washington, <br /> report prepared by GeoEngineers,dated May 31,2017. ("Geotechnical Report") <br /> • Structural Plans, Sheets S001, S002, S003, S201, S201a, S201b, S201c, S207a, S207b, <br /> S301 and S302, prepared by DCI Engineers, dated March 9, 2018, part of 75% Design <br /> Development Plan Set. ("Structural Plans") <br /> • Email from Tom Xia of DCI Engineers to Dan Cianci of GeoEngineers dated 4 June 2018 <br /> indicating the required allowable vertical capacity at individual CSDM columns is 150 <br /> Ups. <br /> • Email dated 6/21/18 From Michelle Kinsch(Tiscareno)transmitting DCI mark-up of HBI <br /> conceptual layout. <br />