Laserfiche WebLink
TABLE 1.2015 IBC SEISMIC DESIGN PARAMETERS • <br /> IBC Parameter Recommended Value <br /> Site Class E <br /> Short Period Spectral Response Acceleration, Ss(g) 1.30 <br /> 1-Second Period Spectral Response Acceleration,Si(g) 0.492 <br /> Seismic Coefficient, FA 0.9 <br /> Seismic Coefficient, Fv 2.4 <br /> Corrected Peak Ground Acceleration)(PGA)(g) 0.494 <br /> Design Earthquake Magnitude2(M) 6.61 <br /> Notes: <br /> 1 Given that the building period is less than 1/2 second and the average blowcount is less than 15,the PGA can be corrected for Site <br /> Class E per ASCE 7-10 Section 11.8.3.A factor of 0.9 was applied to the unfactored PGA of 0.549g to give a corrected PGA of 0.494g. <br /> 2.Given the lateral spreading hazard,the modal maximum magnitude was used in our liquefaction and lateral spreading analyses. <br /> For our liquefaction and lateral spreading analyses, we considered an earthquake magnitude (M) of 6.61 <br /> and a peak ground acceleration (PGA) of 0.494g. Given the lateral spreading hazard, which is dependent <br /> on site to source distance, the modal maximum seismic event was selected as the preferred design <br /> earthquake. The site to source distance for the modal maximum earthquake represents a distance to a <br /> known fault, compared to the mean maximum earthquake which averages the site to source distances and <br /> does not represent the distance to a known fault. <br /> Ground Improvement <br /> The very loose to loose fill and recent deposits below the groundwater elevation are susceptible to <br /> liquefaction. The liquefaction hazard presents a liquefaction-induced (seismic) settlement and lateral <br /> spreading risk.The project team has elected to mitigate seismic settlement and lateral spreading by means <br /> of ground improvement. Interbedded layers of soft silt and clay within the fill are prone to static settlement. <br /> Static settlement will be mitigated with the ground improvement.The proposed buildings may be supported <br /> on shallow foundations bearing on improved ground. <br /> The ground improvement will be designed by Advanced Geosolutions, Inc. We understand that the ground <br /> improvement will consist of cement deep soil mixing(CDSM)columns below building slab and foundations. <br /> We also understand that the ground improvement design will include a CDSM buttress to mitigate lateral <br /> spreading. The CDSM buttress will consist of shear panels with a front closure CDSM wall. <br /> Replacement ratio, spacing and diameter should be determined by the ground improvement contractor <br /> who should develop a performance-based design that will meet the performance criteria presented in <br /> the following section. We recommend that GeoEngineers be retained to review the proposed ground <br /> improvement program and observe the installation of the selected ground improvement method. <br /> Performance Criteria <br /> Ground improvement should be designed to meet the following performance criteria for static and seismic <br /> settlement, lateral spreading and allowable bearing pressure: <br /> a 1 inch of static settlement • <br /> GEOENGINEERS May 31,2017 Page 6 <br /> File No.22360-003-00 <br />