Laserfiche WebLink
RVR <br /> ENGINEERING <br /> 4 '` SYSTEM INFORMATION <br /> " <br /> 4." IRONRIDGE Class A Fire Rating Frequently Asked Questions DC SYSTEM SIZE:3720W <br /> AC SYSTEM 47F•3800W <br /> What is a"module type"? What attachments and flashings are deemed MODULES: <br /> -•- - --Background TheU11703tdditdcompatible with Class A? (12)AXITECAC-310MH/120S <br /> newsanarnrouces the conceptt ea INVERTER: <br /> ef"s PV module type,based on 4 conslmctlon parameters Attachments and their respective flashings are riot (1)SOLAREDGE TECHNOLOGIES <br /> All roofing products are tested and ".,-° - =" - and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code compliant SE3800H-US(240V) <br /> classified for their ability to resist fire. Test Setup this classification is to certi fy mounting systems wilt out flashing methods are acceptable from a fire rating <br /> sa>Moeubs needing to test a with every module. standpoint. ENGINEER OF RECORD <br /> Recently,these fire resistance standards so,,,,„„are given a type <br /> . were expanded to include solar equipment ssn cans,ream on thew ,., What roofin materials are covered? What mountingheight is acceptable? <br /> as part of the roof system.Specifically,this terms and construc <br /> tion <br /> 9 9 <br /> requires the modules,mounting hardware i Mmamng system All fire rated roofi materials are covered within this UL fire testi was rformed with a of 5",which is <br /> and roof covering to be tested together as i s,er ng et itined as°a"m' `> <br /> a system to ensure they achieve the same oddethat <br /> and includes <br /> rroroot wvvering. certification metal,a composition shingle,clay antl c rating <br /> Israp licable to <br /> n tine module <br /> torro Therefore,the <br /> m �,. cement tile,metal,and membrane roofs. ratlng Is applicable to any module to root gap, <br /> fire rating as the original roof covering. I Roet cemni g <br /> Roof cove,ire produda are given a What If t have a Class C roof,but the jurisdiction Am I required to install skirting to meet the fire <br /> These new requirements are being adopted 1 an Chas Retire of A.tor c based <br /> throughout the country in 2016. on heir reared tire rasssance. I now requires Class A or B? code? <br /> __.................._..__.._.................._.._...._............_.........._.................._......__....___...._ 3 <br /> Generally,older roofs will typically be"grandfathered No,IronRidge achieved a Class A fire rating without any <br /> Burning Brand Test in",and will not require re-roofing.However,if 50%or additional racking components. <br /> IronRidge Certification more of the roofing material is replaced for the solar <br /> i installation the code requirement will be enforced. What determines Fire Classification? <br /> IronRidge was the first company to <br /> receive a Class A Fire Rating—the highest eaIT- t Where Is the new fire rating requirement code listedl Fire Classification refers to afire-resistance rating <br /> possible rating—from Intertek Group plc.,a @ . system for roof covering materials based on their ability <br /> Nationally Recognized Testing Laboratory. "' � '-'-- ``"" 2012 IBC:1509.7.2 Fire classification.Rooftop to withstand fire exposure. <br /> A bum rig wooden block s graced on mca�e es a ran door ai tz men. mounted photovoltaic systems shall have the same fire <br /> IronRidge Flush Mount and lilt Mount name cannot be one on umerswe d rod wekn go mousev cWssificatfon as fire roof assembly required by Section Class A-eflecave against severe h}e exposure <br /> Systems were tested on slopedand flat - .....__ 1505 Class B-efecfive against moderate fire exposure y <br /> ys __._.........__..._... ........_ .. ._ Class C-effective against light fire exposure Ace.; <br /> roofs in accordance with the new UL 1703 Spread of Flame Test ;�c <br /> R c,a o >iri&UL 2703 test standards.The testing WOO Where is a Class A Fire Rating required? d'f <br /> evaluated the system's ability to resist What if the roof covering is not Class A rated? ' <br /> flame spread,burning material and The general requirement for roofing systems in the iBC energy today <br /> structural damage to the roof. 'I refers to a Class C fire rating.Class Aor B is required for The IronRidge Class A rating will not diminish the fire <br /> areas such as Wildland Urban Interface areas(WUI)and rating of the roof,whether Class A,B.or C. <br /> •d� •'•:tJ• for very high fire severity areas.Many of these areas are CUSTOMER INFORMATION <br /> Refer to the table below to determine the found throughout the western United States.California <br /> What <br /> requirements for achieving a Class A Fire has the most Class A and B roof fire rating requirements,has is the tilt mount system fire rated for? <br /> NAME&ADDRFSS: <br /> Rating on your next project. Flame at sannem saga or rocs h aimed up mo rod as a son blows as tz due to wild fire concerns. <br /> m°h.The fl not sa ad a feet or mo - to ores. S The tilt mount system is rated for 1 degrees and up and RITA BLANKENSHIP <br /> any roof to module gap,or mounting height 7611 EASY ST,EVEREfT,WA 98203. <br /> ..-._. "." Are standard mid clamps covered? <br /> '='+'E"•rKt`. T �^' °'C" ` `, r,„ Mitl clam and end clam s are considered n of the 47.5543.73"N 122°13'43.50"W <br /> PV"system",and are covered in the certification. APN:003-927-000-002-00 <br /> Flush Mount ` AFU:WA-CITY OF EVERETT <br /> n Any Slope Type 1,2,&3 i Class A <br /> Moro Resources <br /> , <br /> 1 Tilt Mount 4 �- Installation Manuals ' Engineering Certification Letters PROJECT NUMBER,SET1-000473 <br /> s 6 Degrees Type 1,2,&.3 Class A 4,04 Visit our website for manuals that include UL We offer complete engineering resources <br /> f. r '.. 2703 Listing and Fire Rating Classification. and pm-stamped certification letters. <br /> �. . w:.. a. aa.:.e�croa: � ;1 cotainnlxttidev.eont eliesltidgo,aam FIRE RATING SPECSHEET <br /> n P v� v n, 1 n. %aLo✓/1 ;_-I DESIGNER/CHECKED BY: <br /> „_ i .zj`1,,,,.,,,, ,,., ,,,4-: � .Nb „�',..ls _ - W ''. , ,.,���+�i�,rf�i/.�`i.r.�i .,.,... :„�.. ,. .,., ,.. �„_ c q:,sy,I:d; �, <br /> LS/RR <br /> SCALE:AS NOTED PAPER SIZE:17"xl1" <br /> DATE:02/25/2020 REV:A PV-6.8 <br />