Laserfiche WebLink
SINGLE LINE DIAGRAM:DC SYSTEM SIZE-3720W,AC SYSTEM SIZE-3800W <br /> it RVR <br /> o <br /> 5 ENGINEERING <br /> Q EXISTING 120/240V <br /> 1PH 60HZ <br /> SYSTEM INFORMATION <br /> DC SYSTEM SIZE:3720W <br /> (E)200A END FED AC SYSTEM SIZE:3800W <br /> MODULES: <br /> (12)AXITEC AC-310MH/120S <br /> INVERTER: <br /> (E)200A (N)SOLAREDGE TECHNOLOGIES <br /> (1)SOLAREDGE TECHNOLOGIES <br /> MAIN SE3800H-US(240V),3800W SE3800H-US(240V) <br /> BREAKER <br /> (N)30A AC INVERTER-1 (N)JUNCTION (N)AXITEC AC-310MH/1205, <br /> D AM L L N BOX OR *UN 310W MODULES ENGINEER OF RECORD <br /> 12 MODULES WIRED <br /> • -ice 3 3 br n . 2 - 1 4�1i( IN(1)SERIES OF 12 MODULES <br /> 20A 2P PV <br /> BREAKER <br /> (E)GRXUND PV BREAKER AT THE AC DISCONNECT <br /> EEECIR000 OPPOSITE END OF NON FUSED 30A, LOAD RATED DC SOLAREDGE POWER <br /> BUSBAR 120/240V,2P DISCONNECT&AFCI(RAPID OPTIMIZERS <br /> SHUTDOWN COMPLIANCE) <br /> MODULE SPECIFICATION INVERTER-1 SPECIFICATIONS SYSTEM CHARACTERISTICS OCPD CALCULATIONS: <br /> SOLAREDGE TECHNOLOGIES MAIN PANEL RATING:200A, <br /> MODEL AXITEC AC-310MH/1205 MODEL SE3800H-US(240V) DC SYSTEM SIZE 3720 W MAIN BREAKER RATING:200A <br /> MODULE POWER @ STC 310W POWER RATING 3800W INVERTER SIRING VOLTAGE: 380V 120%RULE:(200AX1.2)-200A=40A <br /> OPEN CIRCUIT VOLTAGE:Voc 40.01V MAX OUTPUT CURRENT 16A =>ALLOWABLE BACKFEED IS 40A <br /> MAX INVERTER SYSTEM VOLTAGE: 480V <br /> MAX POWER VOLTAGE:Vmp 32.74V <br /> CEC WEIGHTED EFFICIENCY 99% INVERTER OVERCURRENT PROTECTION= <br /> SHORT CIRCUIT VOLTAGE:Iu 9.96A MAX SHORT CIRCUIT CURRENT 1SA INVERTER 0/P I X CONTINUOUS LOAD(1.25)X <br /> MAX INPUT CURRENT 10.5A <br /> #OF INVERTERS=16x1.25x1=20.00 A <br /> MAX POWER CURRENT:Imp 9.47A MAX DC VOLTAGE 480V OPERATING CURRENT 9.79A <br /> =>PV BREAKER=20A <br /> CONDUIT SCHEDULE OPTIMIZER CHARACTERISTICS ALLOWABLE BACKFEED 40A=>20A PV BREAKER energy today <br /> TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND MODEL P340 THE DESIGNED INTERCONNECTION MEETS THE r Q,e plo,E 0,o.i 1 crn ta^ <br /> 1 NONE (2)10AWG PV WIRE NONE (1)6 AWG BARE COPPER MIN INPUT VOLTAGE 8 VDC 705.12(B)(2)REQUIREMENTS CUSTOMER INFORMATION <br /> ELECTRICAL NOTES: <br /> 2 3/4"EMT OR EQUIV (2)1OAWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 MAX INPUT VOLTAGE 48 VDC 1. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO NAME&ADDRESS: <br /> 3 3/4"EMT OR EQUIV (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 MAX INPUT CURRENT 11 ADC MORE THAN 2%. RITA BLANKENSHIP <br /> MAX OUTPUT CURRENT 15 ADC 2.BREAKER/FUSE SIZES CONFORMS TO NEC 240.6 7611 EASY Sf,EVERETT,WA 98203. <br /> ill CODE SECTION. 47°55'43.73"N 122°13'43.50"W <br /> 3.AC GROUNDING ELECTRODE CONDUCTOR SIZED APN:003-927-000-002-00 <br /> ELECTRICAL CALCULATION PER NEC 250.66. AHJ:WA-CITY OF EVERETT <br /> 4.AMBIENT TEMPERATURE CORRECRON FACTOR IS <br /> DC WIRE CALCULATIONS:-MATERIAL:COPPER&TEMPERATURE RATING:90°C <br /> TAG BASED ON NEC 690.31(A). <br /> ID REQUIRED CONDUCTOR AMPACITY C DBFCTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 5.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS PROJECT NUMBER:S(TI-000473 <br /> 1 1 I X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.58 X 1 = 23.20A 18.75A < 30A 18.75A < 23.20A BASED ON NEC 310.15(B)(2). <br /> 2 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.71 X 0.8 = 22.72A 18.75A < 30A 18.75A < 22.72A 6.MAX.SYSTEM VOLTAGE CORRE TION IS PER NEC <br /> _ _ SINGLE LINE DIAGRAM <br /> 690.7.7. CONDUCTORS ARE SIZED PER WIRE <br /> AC WIRE CALCULATIONS:-MATERIAL:COPPER&TEMPERATURE RATING:90°C AMPACITY TABLE NEC 310.15(8)(16). <br /> DESIGNER/CHECKED BY: <br /> TAG 8.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE /RR <br /> ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). <br /> 3 16 X 1 I= 16.0 X 1.25 = 20.00A 40 X 0.87 X 1 = 34.80A 20.00A < 30A 20.00A < 34.80A <br /> 9. CONDUCTORS EXPOSED TO WET LOCATIONS SCAIE:AS NOTED PAPER SIZE:17"x1l" <br /> SHALL BE SUITABLE FOR USE IN WET LOCATIONS DATE:02/25/2020 REV:A PV-4.0 <br /> PFR NFC 310.10(C). <br /> 5I1 <br />