My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010 LEXINGTON AVE 2022-04-05
>
Address Records
>
LEXINGTON AVE
>
2010
>
2010 LEXINGTON AVE 2022-04-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/5/2022 9:40:40 AM
Creation date
4/5/2022 9:40:37 AM
Metadata
Fields
Template:
Address Document
Street Name
LEXINGTON AVE
Street Number
2010
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2/28/2022 Page <br /> City of Everett <br /> 7:33:48AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E2202-099 Site Address 2010 LEXINGTON AVE <br /> Applied 2/10/2022 Applicant ANTHONY BURNETT Lot <br /> Approved 2/10/2022 Owner ANTHONY BURNETT Block <br /> Issued 2/14/2022 Contractor OWNER Tract <br /> Parent Permit No. W2110-009 Description METER BOX-NEED SERVICE <br /> Notes **SUBJECT TO FIELD INSPECTION** <br /> (10/22/2021 12:27 PMAW) <br /> Speaking with PUD today—they confirmed the property is without approved electrical service.The <br /> power meter has been removed sometime in the past and PUD will not restore power until an Electrical <br /> Permit is issued and the City indicates power can be safely connected. <br /> CE21-0877 code case <br /> Scheduled Completed Tyne Inspector Result Remarks Inspector's Comments <br /> 2/16/2022 2/16/2022 ELEC 05-SERVICE SKB CORRECTION (2/16/2022 11:38 AM SKB) <br /> The insulation on the service entrance <br /> conductors must be stripped off and not in <br /> the lugs.Provide a strap within 3 feet of <br /> meter connecting.Top strap should be <br /> tightened.Close all unused openings in the <br /> panel.Grounded,neutral,conductors must <br /> be terminated in their individual lug,they <br /> cannot be doubled up.Burned conductor in <br /> the grounded bus must be fixed. Secure the <br /> NM cables above the panel.NM cables <br /> must be terminated in a junction box,not <br /> open on the end.Extension cords can not be <br /> ran through doors or walls or used in place <br /> of permanent building wiring.Provide <br /> proper working clearance in front of the <br /> panel.Provide or show the main water bond <br /> within 5 feet of where the water enters the <br /> building. <br /> 2/17/2022 2/17/2022 ELEC 05-SERVICE SKB CORRECTION (2/17/2022 8:07 AM CRB) <br /> PER STEVE HE WILL BE GOING OUT <br /> AT 8:30AM <br /> (2/17/2022 9:40 AM SKB) <br /> Water bond must be a number 4 Copper or <br /> larger and be connected to within 5 feet of <br /> where the water enters the building.Also <br /> bond the gas,it can extend off of the first 5 <br /> feet of water pipe or off of the number 4 <br /> copper.Remove all extension cords <br /> including the ones in the carport extending <br /> from the garage through the walls,properly <br /> terminate whatever they connected to. <br /> Delete the NM cable coming out of the <br /> back of the garage is extending to the soffit <br /> by the carport in the back. <br /> 2/23/2022 2/23/2022 ELEC 05-SERVICE SKB CORRECTION (2/23/2022 11:54 AM SKB) <br /> Finish stapling up the number four water <br /> bond.Finish removing the illegal wiring to <br /> the garage from the panel.Properly support <br /> the new NM cable between the basement <br /> receptacle and light.Install panel cover. <br /> 2/24/2022 2/24/2022 ELEC 05-SERVICE SKB APPRVD-PERM as noted (2/23/2022 12:01 PM CRB) <br /> ADDED FOR CODE ENFORCEMENT <br /> (2/24/2022 11:42 AM SKB) <br /> Service with grounding restored OK for <br /> reconnection call PUD.All unpermitted <br /> work/illegal work feeding to the attic and <br /> garage removed. <br /> INSP12 <br /> SYSTEMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.