My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST SHUKSAN HALL 2022-04-08
>
Address Records
>
TOWER ST
>
2000
>
SHUKSAN HALL
>
2000 TOWER ST SHUKSAN HALL 2022-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2022 9:26:53 AM
Creation date
4/5/2022 2:48:18 PM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
SHUKSAN HALL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Friday,July 23, 2021 2:11 PM <br /> To: psnowden@everettcc.edu <br /> Subject: City of Everett Permit Services: 2000 Tower Street (B2107-058) - First Building Intake <br /> Review <br /> Hello, Mr. Snowden. <br /> Please disregard the previous email and replace with this one. <br /> Your application has been received and a permit set up. However,the submitted documents are not sufficient <br /> for us to perform a review at this time. Revised construction-level documents need to be submitted for <br /> review. Preliminary comments are provided below to assist in revising the drawings, but these are not <br /> intended to provide a comprehensive review. <br /> 1. The proposed project subdivides the existing room, leaving only one exit from the larger room. The <br /> room has an approximate net area of at least 1,020 SF, resulting in an occupant load of 51 based on a <br /> load factor of 20 SF/person per IBC Table 1004.5. Two exits are required per Table 1006.2.1. <br /> 2. Continuing with the previous comment, exit signs and emergency egress lighting is required for the <br /> larger room per Sections 1013 and 1008.3.1, respectively. <br /> 3. One of the smaller rooms is required to exit through the other room. This is not allowed per IBC <br /> Section 1016.2 Item 2. <br /> 4. The minimum door sizes should be specified. The doors should comply with IBC Section 1010.1 and ICC <br /> A117.1-09 Section 404. <br /> 5. A detail should be provided for the construction of the new partition walls. The walls should include <br /> top bracing to resisting a minimum out-of-plane load of 5 psf per IBC Section 1607.15.1. See IBC <br /> Section 107.2.1. <br /> Review of your project will be performed in the order received once the required documentation has been <br /> submitted. Please let me know if you have questions. <br /> Drew Martin, P.E.,S.E. <br /> miAssociate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8813 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Hours: M/W/Th/F: 7:30am-12:OOpm & 1:OOpm-3:OOpm;Tu: 1:00pm-3:00pm <br /> everettwa.gov I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.