My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2621 ROCKEFELLER AVE Geotech Report 2022-10-25
>
Address Records
>
ROCKEFELLER AVE
>
2621
>
Geotech Report
>
2621 ROCKEFELLER AVE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 2:04:54 PM
Creation date
4/5/2022 3:56:28 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2621
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> J <br /> I <br /> fi 6 <br /> _ 0, <br /> 0 -•—•I <br /> E Sloped to Drain Exterior Wall <br /> Away from <br /> Structure <br /> r.: <br /> i 4.) <br /> • Wall Drainage Material <br /> Pavement or 24" g <br /> _'I Impervious Soil------- <br /> Yn <br /> II 03 Retained Soil w f 2' Min. <br /> zi:Temporary , ,Damp Proofing <br /> N Excavation Slope- _ ) '% <br /> I '�*" Vapor Retarder <br /> 1 z ___i , ,, Floor Slab <br /> � l t ,f <br /> mL ;,Y•J JJJr ;V.;✓rr rc..'•;'t..%N 6" Min. <br /> II r e [ <br /> 12" Min. Cover of <br /> Drainage Material <br /> (6" Min. on Sides 4 - Capillary Break <br /> Perforated Drain Pipe <br /> of Pipe) -- <br /> 1 <br /> N <br /> 11 N <br /> rn <br /> E <br /> MATERIALS <br /> 11 z A. WALL DRAINAGE MATERIAL: May consist of washed 3/8" to No. 8 pea gravel. Alternatively the <br /> v wall drainage material may consist of "Gravel Backfill for Drains" per WSDOT Standard <br /> i— Specification 9-03.12(4), surrounded with a non—woven geotextile such as Mirafi 140N (or <br /> o I <br /> approved equivalent). <br /> J <br /> B. RETAINED SOIL: Should consist of structural fill, either on—site soil or imported. The backfill <br /> should be compacted in loose lifts not exceeding 6 inches. Wall backfill supporting building <br /> floor slabs should consist of imported sand and gravel per WSDOT Standard Specification <br /> 11 9-03.14 or City of Seattle Type 17 compacted to at least 95 percent ASTM D1557. Backfill <br /> not supporting building floor slabs, sidewalks, or pavement should be compacted to 90 to <br /> 92 percent of the maximum dry density, per ASTM D1557. Backfill supporting sidewalks or <br /> pavement areas should be compacted to at least 95 percent in the upper two feet. Only <br /> I a, hand—operated equipment should be used for compaction within 5 feet of the walls and no <br /> v heavy equipment should be allowed within 5 feet of the wall. <br /> ri <br /> u <br /> o C. CAPILLARY BREAK: Should consist of at least 6 inches of clean crushed gravel with a <br /> II o maximum size of 1-1/2 inches and negligible sand or fines. <br /> 0 <br /> N. <br /> ''�n D. PERFORATED DRAIN PIPE: Should consist of a 4—inch diameter perforated heavy—wall solid <br /> N pipe (SDR-35 PVC) or rigid corrugated polyethylene pipe (ADS N-12) or equivalent. Drain <br /> o pipes should be placed with 0.5 percent minimum slopes and discharge to the storm water <br /> collection system. <br /> o <br /> o <br /> o Wall Drainage and Backfill <br /> N. <br /> N <br /> 1 Rockefeller Apartments <br /> -I Everett, Washington <br /> eL <br /> jILaGEOE'NGINEER Figure 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.