My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10632 ROSEWOOD AVE 2022-04-06
>
Address Records
>
ROSEWOOD AVE
>
10632
>
10632 ROSEWOOD AVE 2022-04-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 8:15:16 AM
Creation date
4/6/2022 7:50:54 AM
Metadata
Fields
Template:
Address Document
Street Name
ROSEWOOD AVE
Street Number
10632
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table i to 63285.402-Maximum Diagonal Tie-Down Strap Spacing,Wind Zone 1 -STANDARD <br /> Nominal floor width, Max.height from CHASSIS PIER SILLL CHASSIS <br /> single section/multi- ground to diagonal I-beam spacing - BEAM - - <br /> section strap attachment <br /> 84.ft. N/A.in. in. — r - _` u 12/24 ft.144 in. 25 in 14 2 in N/A. <br /> nominal section(s) 33 in 11 ft.9in N/A. <br /> 46 in 9 ft.lin N/A. <br /> 67 in N/A N/A. ONGITUDINAL <br /> 14/28 ft.168 in. 25 in 18 ft.2in 15 ft.11 in. EDOWN STRAP TIEDOWN <br /> nominal section(s) 33 in 16 ft.1 in 13 ft.6 in. BRACKET <br /> 46 in 13 ft.3 in 10 ft.8in. <br /> 67 In 10 ft.0in N/A. —� — — --_ --16/32 ft.180 in.to 192 25 in N/A 19 ft.Sin.in.nominal section(s) 33 in 19 ft.0 in 17 ft.5 in. j11„. <br /> ROUND ANCHOR <br /> 46in 16 ft.5in 14ft.7in. <br /> 67 in 13 ft.1in 11 ft.3in. Longitudinal Anchorage — Plan View <br /> WIND ZONE I TARE NOTES <br /> 1. Table is barred on maximum 90 in.sideaol height <br /> 2. Table is based on maximum 4 in.Inset far ground anchor head from edge — <br /> of Soar or warn <br /> 3. Table is based on main roll(I-beam)sparing per given column. <br /> 4. Table is based on maximum 4 in.eave width for single-section homes and STEEL <br /> maakesm 12 tn.for multi-section homes. STANDARD CHASSIS -LONGITUDINAL <br /> 5. Table is based on maximum 20-degree roof pitch(4.342). CHASSIS BEAM TIEDOWN ANCHOR <br /> 6. Table is based upon the minimm height between the ground and the PIER <br /> bottom of the Boor joist being 18 inches.Interpolation may be required for other <br /> heights from grand to strap attachment. <br /> 7. Addibnaf tb-downs may be required per the home manufacturer / \` <br /> 8. Grand anchors must be certified for these conditions by a professional / — \ — <br /> engineer.architect,or fisted by a nationally recognize!testing laboratory. / — \\ — <br /> 9. thud anchors must be instated to their full depth,and stabfther plates, <br /> If spied by the ground anchor listing or certification,must also be installed In I I / I l I i I <br /> accordance with the listing or certification and in accordance with the ground anchor and home manufacturer instructions. _ I I <br /> 10. Strapping and anchoring equipment must be certified by a registered ' <br /> professional engineer Cr registered architect.or listed by a nationally recognized GROUN <br /> testies agency to resist these specified forces,in accordance with testing i ANCHOR 1 <br /> proms in AS1M 0 3953-97,Standard Specification for Strapping,flat Sted <br /> and throb(increporated by reference,see§3285.4). Longitudinal t u d i n a l Anchorage — Side View <br /> D. A reduced ground anchor or strop working load capacity will rewire reduced <br /> g <br /> tie-down strap and abhor sparing. <br /> 12. Ground anchors must not be spaced dear then the minimum spacing <br /> per/died by the listing or certification. <br /> 13 Table n based on a 3,150 lbs.working load aopasitg and straps must be PROPRIETARY ANCHORING SYSTEM NOTES <br /> placed wdthn 2 ft of the ends of the home. 1. Proprietary anchorite systems may be installed in lieu of galvanized straps. <br /> it Table is based on a minimum angle of 30 degrees and a madmum angle 2. install proprietary anchoring systems in compliance with the system manufacturer's <br /> of ED degrees between the diagonal strap and the ground. written installation nstnutions for the manufactured home's size and roof slope in this Wind <br /> 15. Fable does not consider flood or seismic loads and le not intended for use Zone. <br /> In thud or mimic hazard areas.In those areas the anchorage system is to be <br /> designed by a professional engineer or architect. <br /> Sheet 2/2 <br /> This design meets or exceeds the requirements of On Frame Manufactured Home <br /> • HUD Permanent Foundation Guide to Manufactured Housing dated TYLE <br /> September 1996 (HUD 7584 4930.3) Permanent Foundation Design y-.ti R 4e9 <br /> • 24 CFR Part 3285 Model Manufactured Home installation Standards 'Z' ,/W`�SEUt, ''4f- <br /> Copyright 2018 Hayman Engineering. All Rights Reserved. ,, G, <br /> The foundation at the following address, when installed in compliance with 1- •A0 �0 <br /> the attached design, will meet HUD criteria for a Permanent Foundation. }} <br /> Owner: Rod and Victoria Lucas <br /> H AY M A N ENGINEERING, I N G Address: 10632 Rosewood Ave 4 956 ` <br /> 9' 723 Broad St.,Columbia,MS 39429 Everett,WA 98204 ©,t• �vLTISTER'� w <br /> Michael Barker,PERegistered Professional Engineer Washington License No.55956 Job No: 21050274 .S/l3NAL '''74`o1 <br /> Board of Engineers-Firm License(COA)2625 Date: 05/12/21 <br /> (417)831-5550 hfeorders@haymanengineering.com Dwn By: KLR Chkd By: MB <br /> 05/12/21 <br /> Qs‘311_&_.) <br />
The URL can be used to link to this page
Your browser does not support the video tag.