MINUTE MAN ANCHORS, INC. <br /> b 305 WEST KING STREET <br /> •.a90Y WASyjyr EAS FLATROCK, <br /> 438-NC 28726 <br /> ��Q~, ry ENGINEERED TIE DOWN SYSTEM <br /> u - DESIGN&GENERAL NOTES <br /> v, - , ,.r DESIGN LOADS: - <br /> f_- /ir - .- •WIND---------------15 PSF(70 MPH EXPOSURE"C")CAC T-25 and <br /> �� 14176 ti • COMPLIES WITH 2010 C.R.C. 85 M.P.H.EXP.C,105 MPH Exp"C", 2012113C <br /> rG� �4rISI��� ��, •TIEL BEARING DOWN STRAP __1500 PSF <br /> 3150#WORKING LOAD <br /> 4'SSIONAL V;—C� <br /> •SEISMIC ZONE 4 CAC T-25 AND 2010iG•R.q.Sx=1A Fa= S s1.41 Site Class <br /> TIE DOWN STRAPS TO BE MIN.1 1/4"WIDE x 0.035 THICKNESS ZINC PLATED AND <br /> 7_1-� J� MEET ASTM D-395391 <br /> DEARTH AUGERS 3150#(tested to 4725#min) CROSS DRIVES(soilYr.15754t(calculated,see£-en Note-4 <br /> ��\ CROSS DRIVES(asphalt)...1800#(tested to 3600#) asphalt min 2.5"thiok— <br /> A- U,�`y'L � J .CROSS DRIVES(solid rock)..3150#(tested to 4725#min) . <br /> yL` ••• •. .• �� CONCRETE SLAB ANCHORS....3150#(tested to 4725#min)drill proper size pilot hole min 4"from any edge <br /> )��t,V�S •p•.r '', ` GENERAL NOTES: <br /> J ' • 1. THE CHARTS SHOWN HEREIN ARE FOR THE REQUIRED NUMBER OF TIE DOWNS <br /> * /, L u �� ON THE SIDES OF THE MANUFACTURED HOME. <br /> i, I823 L } t ! 2. TIE DOWNS ARE REQUIRED AT EACH CHASSIS BEAM,EACH END OF EACH <br /> O <br /> �*+ TRANSPORTABLE SECTION OF THE MANUFACTURED HOME AND CAN BE ANY <br /> r "�' OF THE TYPES SHOWN HEREIN. <br /> •&pMM.*.,�.ep� 3. COMBINATIONS OF THE DIFFERENT TYPES OF TIE DOWNS CAN BE USED. <br /> lT BE INSTALLED DUE TO AN <br /> C Of•CD`'44 r 4. OBSTRUCTION,USE OF CROSS DRIVE AIN THE EVENT AN EARTH AUGER ONCHORS IS PERMITTED,PROVIDED(2) <br /> .� CROSS DRIVES ARE INSTALLED FOR EACH EARTH AUGER THAT CANNOT BE <br /> ,Y,, re--- INSTALLED. <br /> 5. FOR ALL TIE DOWN INSTALLATIONS,THE MFG'D HOME CHASSIS MEMBERS ARE <br /> SHOWN AS"I"BEAMS.FOR ILLUSTRATION PURPOSES ONLY.CHASSIS BEAMS <br /> CAN ALSO BE"C"SHAPED OR"RFC"SHAPED. <br /> (-___.:1--.-.. <br /> ionFq 6. END TIE DOWNS CAN BE LOCATED WITHIN 24"OF EITHER SIDE OF CHASSIS <br /> T 1�� BBEAM AXIS AS SHOWN. - N.' 2: H. 1B"MIN.VID 7. THE SIZES,TYPES,LENGTHS,ECT.OF MATERIAL SHOWN HEREIN ARE <br /> HMEMij MINIMUM.LARGER,LONGER,HEAVIER MATERIALS SUPPLIED BY MINUTE-MAN <br /> N` PRODUCTS.MAY BE USED AT THE SAME SPACING&LOCATION SHOWN.ned:• 8. ALL PARTS ARE STAMPED MMA-WITH THE APPROPRIATE PART NUMBER. <br /> i0-5' • 9. THIS TIE DOWN SYSTEM CAN BE USED WITH 10'WIDE MANUFACTURED HOME <br /> • SECTIONS WITH 100"CHASSIS CENTERS PROVIDED THE HEIGHT FROM GRADE TO <br /> f--.0-P cl_.I- (i.f THE BOTTOM OF THE CHASSISBEAM DOES NOT EXCEED 19". <br /> 10.TIE DOWN STRAPS IN THE LONGITUDINAL OR TRANSVERSE DIRECTION CAN BE <br /> BOLTED TO THE HITCH ATTACHMENT PLATE THAT IS WELDED TO THE CHASSIS BEAM. VIP-la-09 <br /> --,' 1Hu 2 , NGINEER APPROVAL `v' STATE APPROVAL 1 <br /> <<�+� fi 97 SE AGE"2" FOR LISTING INFORMATION <br /> D VID ALLEPI QQ�OF O �' / ENGINEERED TIEDOWN SYSTEM <br /> Li DAHMEN ��7� APPROVED <br /> CDC" !rt �aR 1• �',- SUBJECT TO CORRECTIONS NOTED <br /> O- NO 119572- I//v, ..r Approved does not authorize or approve any omission or <br /> deviation from requirements of applicable State laws and <br /> / P 7 A •-•,.. MI5 a regulations <br /> 'rE Of UC'4 4 I0 3U State of California <br /> Department of Housing and Community Development <br /> y. J} '--loT en*:• '.4'%'•1, DIVISION OF CODES AND STANDARDS <br /> OF MA S By f, Date./��`�3 <br /> / (Signature) ) W <br /> PACIFIC CONSULTING ENGINEERS SPA NO ETS l/-9 G:- z-4 �F r <br /> • 2150 BELL AVE. SUITE 145 _ ___ 0 <br /> SACRAMEN(916) 64-6028CALIFORNIA 95838 This Plan Approval Expires .2j lc7 <br /> PH: 564 6028 <br /> QED ROFE 4 <br /> A0 c4.:..;,... <,,,, <br /> ,ifi 14•. ! ��� OkNEF9 f>o ••r' .•/8' <br /> ' : <br /> e 1462 / ;. . 00 AVID A. - 'i <br /> Ii, -s- /d,,e ,...-e;," ./ f 44 : DAHMEN <br /> A. D .- l},�� Zo, �4# . <br /> - ...? .• <br /> £xp 7--31- ! r4ao, 3025 <br /> £xro i a 3,l- �7 _. �. .i z-st-is <br />