My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7611 EASY ST 2022-04-08
>
Address Records
>
EASY ST
>
7611
>
7611 EASY ST 2022-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2022 4:10:30 PM
Creation date
4/8/2022 4:10:03 PM
Metadata
Fields
Template:
Address Document
Street Name
EASY ST
Street Number
7611
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RVR <br /> ENGINEERING <br /> 1495 Zephyr Avenue 1495 Zephyr Avenue SYSTEM INFORMATION <br /> Zer IRONRIDGE Hayward,CA94544 IRONRIDGE Hayward,CA94544 DCSYSTEMN SIZE:3720W <br /> 1-B00-227-9523 1 7-9523 <br /> I IronRidge.com IronRidge corn AC SYSTEM SIZE:3800W <br /> MODULES: <br /> Attn:Corey Geiger,COO,IronRidge Inc. (12)AXITEC AC-310MH/120S <br /> Date:September 7"',2018 The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no INVERTER: <br /> consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting (1)SOLAREDGE TECHNOLOGIES <br /> Re:Structural Certification and Span Tables for IronRidge Flush Mount System members.It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the SE3800H-US(240V) <br /> aforementioned system components In regards to the applied or resultant toads of any chosen array configuration. ENGINEER OF RECORD <br /> This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System.The Flush <br /> Mount System is a proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or Q�ct1yQty���� . <br /> landscape orientation and set parallel to the underlying root surface.PV modules are supported by extruded aluminum Sincerely, QO'"a "N <br /> XR Rails and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof Date: <br /> attachment with 3/8'stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion P2 `r ry a <br /> that is fastened to the underlying roof structure.Assembly details of a typical Flush Mount installation and its core '._ NA.5M ,y j �-. f ^-' 201 8.09.1 0 <br /> components are shown in Exhibit EX-0015. 1 6:29:47-07r00r <br /> The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards ,' <br /> listed below,for the load conditions and configurations tabulated in the attached span tables. Gang Xuan,SE <br /> • ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) Senior Structural Engineer <br /> • 2015 International Building Code(IBC-2015) <br /> • 2016 Calrfomia Building Code(CBC-2016) <br /> • 2015 Aluminum Design Manual(ADM-2015) <br /> The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the <br /> respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones 1,2&3,and roof <br /> slopes from 0°to 45°.The span tables are applicable provided that the following conditions are met <br /> 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment <br /> fastener) <br /> 2. The underlying roof pitch,measured between roof surface and horizontal plane,is 45°or less. 'I energy today <br /> ca�F,w,b,r Ehis.1-._ r,-, <br /> 3. The mean roof height,defined as the average of the roof save height and the roof ridge height measured from CUSTOMER INFORMATION <br /> grade,does not exceed 30 feet <br /> 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module NAME&ADDRESS: <br /> width shall not exceed 48'. RITA BLANKENSHIP <br /> 7611 EASY ST,EVERETT,WA 98203. <br /> 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount <br /> • installation manual and other applicable standards for general roof construction practice. 47°55'43.73"N 122°13'43.50"W <br /> APN:003-927-000-002-00 <br /> AHJ:WA-CITY OF EVERETT <br /> PROJECT NUMBER:SE t-000473 <br /> 0201e IronRidge,Inc. CA Flush Mount system Certirigtion Letter-1 o2018 IronRidge.Inc. CA Flush Mount System Cennceson Letter-4 MOUNT CERTIFICATION <br /> DESIGNER/CHECKED BY: <br /> LS/RR <br /> SCALE:AS NOTED PAPER SIZE:17'x11" <br /> DATE:02/25/2020 REV:A PV-6.7 <br /> L-\ \ ls <br />
The URL can be used to link to this page
Your browser does not support the video tag.