SINGLE LINE DIAGRAM:DC SYSTEM SIZE-3720W,AC SYSTEM SIZE-3800W <br /> no RVR <br /> 5(7 ENGINEERING <br /> MISTING <br /> ISTING 120/240V <br /> IPH 60HZ SYSTEM INFORMATION <br /> DC SYSTEM SIZE:3720W <br /> (E)200A END FED AC SYSTEM SIZE:3800W <br /> MODULES: <br /> I <br /> (12)AXITEC AC-310MH/120S <br /> INVERTER: <br /> (E (N)SOLAREDGE TECHNOLOGIES (1)SOLARED(iE TECHNOLOGIES <br /> SE3800H-US(240V),3800W(N)30A AC INVERTER-1 SE3800H-US(240V) <br /> ..A,.,, N BOX OR'UIV 310W MODULESIOMH/1205, ENGINEER OF RECORD <br /> 12 MODULES WIRED 3 3 ME . 2 1 . j IN(1)SERIES OF 12 MODULES ' <br /> 20A 2P PV <br /> BREAKER <br /> (E)GROUND PV BREAKER AT THE AC DISCONNECT <br /> ELECTRooE OPPOSITE END OF NON FUSED 30A, LOAD RATED DC SOLAREDGE POWER <br /> BUSBAR 120/240V,2P DISCONNECT&AFCI(RAPID OPTIMIZERS <br /> SHUTDOWN COMPLIANCE) <br /> MODULE SPECIFICATION INVERTER-1 SPECIFICATIONS SYSTEM CHARACTERISTICS OCPD CALCULATIONS: <br /> SOLAREDGE TECHNOLOGIES MAIN PANEL RATING:200A, <br /> MODEL AXITEC AC-310MH/1205 MODEL SF3800H-US(240V) DC SYSTEM SIZE 3720 W MAIN BREAKER RATING:200A <br /> MODULE POWER @ STC 310W POWER RATING 3800W INVERTER STRING VOLTAGE: 380V 120%RULE:(200AX1.2)-200A=40A <br /> OPEN CIRCUIT VOLTAGE:Voc 40.01V MAX OUTPUT CURRENT 16A =>ALLOWABLE BACKFEED IS 40A <br /> MAX INVERTER SYSTEM VOLTAGE: 980V <br /> MAX POWER VOLTAGE:Vmp 32.74V <br /> CEC WEIGHTED EFFICIENCY 99% INVERTER OVERCURRENT PROTECTION= <br /> MAX INPUT CURRENT 10.5A MAX SHORT CIRCUIT CURRENT 15A INVERTER 0/P I X CONTINUOUS LOAD(1.25)X <br /> SHORT CIRCUIT VOLTAGE:oc 9.96A '`�% <br /> #OF INVERTERS 16x1.25x1 20.00 A { <br /> 4.erMAX POWER CURRENT:Imp 9.47A MAX DC VOLTAGE 480V OPERATING CURRENT 9.79A =>PV BREAKER=20A <br /> CONDUIT SCHEDULE OPTIMIZER CHARACTERISTICS ALLOWABLE BACKFEED 40A=>20A MI BREAKER energy today <br /> TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND MODEL P340 THE DESIGNED INTERCONNECTION MEC i S THE co.Sa'^Rik c. ;xrts€wr;.. <br /> 1 NONE (2)10AWG PV WIRE NONE (1)6 AWG BARE COPPER MIN INPUT VOLTAGE 8 VDC 705.12(B)(2)REQUIREMENTS CUSTOMER INFORMATION <br /> ELECTRICAL NOTES: <br /> 2 3/4"EMTOR EQUIV (2)10AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 MAX INPUT VOLTAGE 48 VDC 1. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO NAME&ADDRESS: <br /> 3 3/4"EMT OR EQUIV (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 MAX INPUT CURRENT 11 ADC MORE THAN 2%, RITA BLANKENSHIP <br /> MAX OUTPUT CURRENT 15 ADC 2.BREAKER/FUSE SIZES CONFORMS TO NEC 240.6 7611 EASY Si,EVERETT,WA 98203. <br /> ilk <br /> CODE SECTION. 47.55'43.73"N 122°13'43.50"W <br /> 3.AC GROUNDING ELECTRODE CONDUCTOR SEED APN:003-927-000-002-00 <br /> ELECTRICAL CALCULATION PER NEC 250.66. AHJ:WACRY OF EVERETT <br /> 4.AMBIENT TEMPERATURE CORRECTION FACTOR IS <br /> DC WIRE CALCULATIONS:-MATERIAL:COPPER&TEMPERATURE RATING:90°C <br /> BASED ON NEC 690.31(A). <br /> TAG REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DEBATED CONDUCTOR AMPACITY CHECK <br /> ID 5.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS PROJECT NUMBER:SETI-000473 <br /> 1 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.58 X 1 = '23.20A 18.75A < 30A 18.75A < 23.20A BASED ON NEC 310.15(11)(2). <br /> 2 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.71 X 0.8 = 22.72A 18.75A < 30A 18.75A < 22.72A 6.MAX.SYSTEM VOLTAGE CORRECTION IS PER NEC SINGLE LINE DIAGRAM <br /> 690.7.7. CONDUCTORS ARE SIZED PER WIRE <br /> AC WIRE CALCULATIONS:-MATERIAL:COPPER&TEMPERATURE RATING:90°C AMPACITY TABLE NEC 310.15(B)(16). <br /> DESIGNER/CHECKED BY: <br /> TAG 8.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LS/ <br /> RR <br /> ID, REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DEBATED CONDUCTOR AMPACITY CHECK LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). <br /> 3 16 X 1 = 16.0 X 1.25 = 20.00A 40 X 0.87 X 1 = 34.80A 20.00A < 30A 20.00A < 34.80A <br /> 9. CONDUCTORS EXPOSED TO WET LOCATIONS SCALE:AS NOTED PAPER SEE:17"xll" <br /> SHALL BE SUITABLE FOR USE IN WET LOCATIONS <br /> DATE:02/25/2020 REV:A PV-4.0 <br /> PER NFC 310.10(C). <br /> 5 I VS <br />
The URL can be used to link to this page
Your browser does not support the video tag.