Residential Plumbing Sewer and Drainage Investigation <br /> Site Address: <br /> 306 Alder Street <br /> Everen WA 98201 <br /> 9/26/]3 <br /> .� . <br /> :;i` <br /> Plumbina and DrainaEe Insoector: <br /> Steve's Plumhing LLC <br /> 19707 64'"Ave W,#108 <br /> Lynnwood, WA 98036 <br /> House Soecifics: <br /> • House currently has a backwater valve on side sewer?NO <br /> • House has downspouts connected to side sewer?NO <br /> • No roof or perimeter drain [ie into private side sewer <br /> • Does Side Sewer have grade?YES <br /> • Approximate depth of side sewer: 4' at home, 12' at city main <br /> • Depth and Localion of proposed Backwater Valve: 4'deep under concrete side walk between <br /> houseand hedge <br /> Plumbire,Sewer,or Drainaee Problems Identified: <br /> I)House is not protected from a sewer surcharge event. <br /> Su�ested Solution: Install a backwater valve 4'deep under concre[e side walk belween house and hedge. <br /> See attached sketch and photos. <br /> 2) Side Sewer Notes: Sewer is approx. 26' in length; depth is 4' at home and 12' at city main Line is <br /> existing concrete and has root inwsions at multiple joint locations,probably due the hedge <br /> Suggested Solution: Re-lining Side sewer to prevent future blockages due to the roo[s. <br /> ia <br />