Laserfiche WebLink
o. Windshield wipers interlocked to the parking brake so that they stop operating when the brake is set. <br />The apparatus must include a momentary switch on the instrument panel that activates the <br />intermittent feature of the windshield wipers while the brake is set. <br />2.7.2 WATER PUMP SYSTEM <br />a. 500-gallon water tank configured to allow for hose beds to be as low as possible. <br />b. 2000 Gallon Per Minute (GPM) Class A Hale midship fire pump. <br />c. Pump controller will be a pressure governor type. <br />d. Compressed air primer. <br />e. Four (4) inlets of the following sizes and locations: <br />1. One (1) 6" inlet on the left side pump panel. <br />2. One (1) 2.5" inlet on the left side pump panel. <br />3. One 6" inlet on the right -side , %•* <br />(1) pump panel. <br />4. One (1) 2.5" inlet on the right -side pump panel. <br />f. TFT ball inlet valves on both 6" inlets — model to be determined at pre -con. <br />g. <br />Ten (10) discharge (outlets) of the following sizes and locations: <br />1. One (1) 2.5" outlets on the left rear of the apparatus — foam capable. <br />2. One (1) 2.5" outlet on the right rear of the apparatus — foam capable. <br />3. Two (2) 2.5" outlets on the left pump panel. <br />4. One (1) 2.5" outlet on the right pump panel controlled by two (2) electric valve controllers, one at <br />each pump panel. <br />5. One (1) 1.5" outlet on the right -side pump panel controlled by two (2) electric valve controllers, <br />one at each pump panel — foam capable. <br />6. One (1) 5" outlet capable of flowing the pumps rated capacity located on the right -side pump <br />panel terminating with a 5" Storz fitting. The outlet will be controlled by two (2) electric valve <br />controllers, one at each pump panel — foam capable. <br />7. One (1) 4" deluge riser outlet installed above the pump. The plumbing will be 4" inside diameter <br />and must include a full flow electronic valve. The outlet will be controlled by two (2) electric valve <br />controllers, one at the pump panel and one near the outlet. <br />8. One (1) outlet capable of supplying a booster reel located on top side with minimum 150 feet of <br />1" hose. <br />9. One (1) 1.5" outlet on the top side front bumper — foam capable. <br />h. Rack and sector Waterous discharge valves where push pull valves are utilized. <br />Page 10 of 27 <br />