Laserfiche WebLink
A PORTION OF SECTION 17, T 29 N, R 5 E, WM <br />GENERAL CONSTRUCTION NOTES <br />1. ALL WORK AND MATERIAL SHALL CONFORM TO THE CITY OF EVERETT <br />STANDARDS AND STANDARD SPECIFICATIONS OF WDSOT/APWA. <br />2. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM <br />AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID <br />DAMAGE TO ANY ADDITIONAL UTILITIES SHOWN. IF CONFLICTS WITH EXISTING <br />UTILITIES ARISE DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE <br />DISTRICT AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE <br />ENGINEER PRIOR TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE <br />PROJECT, <br />3. NO PART OF THE DRAINAGE SYSTEM SHALL BE COVERED, CONCEALED OR PUT <br />INTO USE UNTIL IT HAS BEEN INSPECTED, TESTED AND ACCEPTED. <br />4. ALL STORM SYSTEMS WITHIN THE PUBLIC RIGHT—OF-WAY OR IN EASEMENTS <br />MUST BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO STARTING <br />CONSTRUCTION. <br />5. ALL CATCH BASIN GRATES MUST BE STENCILED OR STAMPED "DUMP NO <br />WASTE, DRAINS TO STREAM, LAKE, RIVER, PUGET SOUND OR WETLAND". <br />CHOOSE APPROPRIATE FEATURE FOR THE PROJECT. <br />6. CONTRACTOR TO PROVIDE STORM WATER BYPASS AS REQUIRED FOR <br />DEWATERING DURING CONSTRUCTION OF NEW SYSTEMS. <br />7. CONTRACTOR TO OVEREXCAVATE AS NECESSARY TO. PROVIDE STABLE <br />FOUNDATION FOR STRUCTURES. <br />8, WHERE TRENCH EXCAVATION EQUALS.OR EXCEEDS A DEPTH OF 4 FEET, THE <br />CONTRACTOR SHALL PROVIDE, CONSTRUCT, MAINTAIN AND REMOVE , AS <br />REQUIRED, SAFETY SYSTEMS THAT MEET THE REQUIREMENTS OF THE <br />WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, RCW 49.17, INCLUDING <br />WAC 296-155. <br />�Q. <br />. t <br />r <br />Graloo0ofto <br />12" X 12" CATCH BASIN WITH 2 OPENINGS (NDS PART NO.1200 OR EQUIVALENT) <br />12" ATRIUM.GRATE (NDS PART NO. 1280 /1290 OR EQUIVALENT) <br />1- 4" UNIVERSAL OUTLET <br />1- 6" UNIVERSAL OUTLET <br />AREA DRAIN W/ ATRIUM GRATE DETAIL <br />REF: NDS PART NO.'S 1200 & 1280 <br />NO SCALE <br />ATTACH IN A MANNER THAT <br />ASSURES FABRIC IS FIRMLY <br />HELD BY THE BACKUP <br />SUPPORT IN AWAY THAT <br />REDUCES THE POTENTIAL <br />FOR FABRIC TEARING --- <br />BACKUPSUPPORT <br />BACKFILLED & <br />COMPACTED <br />NATIVE SOIL --\ rfnTFxTu <br />POST SEE WSDOT STANDARD <br />SPECIFICATION5.8-01.3(9)A <br />FASTEN GEOTEXTILE TO <br />POST EVERY 6" IN O.C. <br />Rz <br />SELF-LOCKING TIE-NYLONE <br />6/6 (MIN GRADE] <br />120# MIN TENSILE STRENGTH,. <br />s UV STABILIZED <br />4 =8 QUARRY SPAL S BURY GEOTEXTILEPLACE GEOTEXTILE UNDER SPALLS <br />GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: 1N TRENCH — <br />P <br />4 Z► Q- - z <br />GRAB TENSILE STRENGTH (ASTM D-4751) = 200 PSI MIN c4 4y� <br />GRAB TENSILE ELONGATION ASTM D-4632) = 30% MIN `w <br />MULLEN BURST STRENGTH . (ASTM D-3786-800) = 400 PSI MIN <br />AOS (ASTM D-4751) = 20-45 (U.S.. STD SIEVE SIZE) <br />BEEHIVE GRATE <br />FLOATAB-L-E--MATERIAL SEPARATORA GAS TRAP <br />BASED ON • <br />NO SCALE <br />PLAN VIEW <br />20" X 24" . <br />10" X 12" <br />6 1/4" <br />1 1 /2" <br />_T <br />20" X 24" <br />SECTION MEW <br />BEEHIVE GRATE DETAIL <br />REF:. OLYMPIC FOUNDARY PART NO. SM60BH <br />NO SCALE <br />BOTANICAL NAME <br />COMMON NAME <br />PLANTING ZONE <br />MATURE HEIGHT <br />PLANT SPACING <br />QUANTITY <br />JUNCUS ENSIFOLIUS <br />DAGGER LEAF RUSH <br />ZONE 1 <br />12" TO 18" <br />36" OC <br />15 <br />JUNCUS ACUMINATUS <br />TAPER TIPPED RUSH <br />ZONE 1 <br />6" TO 18" <br />24" OC <br />10 <br />IRIS TENAX <br />OREGON IRIS <br />ZONE 1 <br />12" TO 18" <br />12" OC <br />30 <br />TIARELLA TRIFOUATA <br />FOAM FLOWER. <br />ZONE 2 <br />12" <br />12" OC <br />30 <br />GEUM <br />AVENS <br />ZONE 2 & 3 <br />8" TO 20" <br />12" OC <br />30 <br />GERANIUM <br />CANTABRIGIENSE <br />BIOKOVO HARDY <br />GERANIUM <br />ZONE 2 & 3 <br />6" TO 8" <br />8" OC <br />60 <br />V <br />Z <br />N <br />r- <br />ZW <br />�?R� <br />0 <br />>Q <br />® �02 <br />W <br />_ <br />> N .� <br />STABILIZED CONSTRUCTION ENTRANCE TEMPORARY SILT FENCE <br />TYPICAL RAIN GARDEN PLANTING ZONES RAIN GARDEN PLANTING SCHEDULE a <br />NO SCALE PER C.O.E. STD. DWG 214 :� <br />NO SCALE PER RAIN GARDEN HANDBOOK FOR WESTERN WASHINGTON '4 > rL <br />I <br />NO SCALE ®Q w <br />® 0 <br />o NOTES <br />NOTES DESIGN: <br />1. SEE THE RAIN GARDEN HANDBOOK FOR WESTERN <br />5" MAX 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it WASHINGTON FOR DESIGN AND. PLANTING <br />o will service. INSTRUCTIONS. NATIVE PLANTS ARE PREFERRED, REVISIONS: APPD. <br />o BECAUSE NON-NATIVE AND INVASIVE SPECIES CAN <br />2 DRAINAGE GRATE TRIM <br />MOVE DOWNSTREAM AND DAMAGE HABITAT. IF <br />2. The BIGD shall have a built-in high -flow relief system (overflow bypass). <br />NON -NATIVES ARE CHOSEN,. BE SURE THAT THEY WILL <br />0 3. The retrieval system must allow removal of the BIGD without spilling the NOT DAMAGE DOWNSTREAM HABITAT. <br />r GRATE FRAME collected material. 6°-12" TYPICAL. 2. RAIN GARDENS MAY BE USEDTO MEET <br />U PONDING DEPTH ------ <br />STQRMWATERMINIMUM_ EQUIREMENT#5 FOR <br />W a D o a 4. Perform maintenance in accordance with Standard Specification 8-01.3(15). SITESlAIHICH ADD OR REPLACE LESS THAN 50005F OF <br />3H:1V SIDE SLOPE MAX TYPICAL NEW OR REPLACED HARD SURFACE. <br />Z <br />PLANTINGS <br />O SEDIMENT AND DEBRIS <br />CLEAN OUT SET CAP HIGHER 3. PROVIDE FAIN GARDEN INFORMATIVE SIGNS FOR. <br />a " a THAN. MAX WATER LEVEL BERM AS NEEDED RAIN GARDEN ASSOCIATED WITH NEW <br />Cf)OVERFLOW BYPASS <br />o a CONSTRUCTION, SIGNS ARE AVAILABLE FROM PERMIT <br />z C.,OMPACTED NATIVE FILL SERVICES.LU <br />. <br />1-2`" MULCH WIDTH '(S' MIN) EXISTING GRADE <br />r r•�wi` 4.. MAINTENANCE AGREEMENTS ARE REQUIRED FOR <br />RETRIEVAL SYSTEM <br />U r,: ,=1i✓:=;n ° RAIN GARDEN INSTALLATION USED TO MEET <br />DRAINAGE GRATE (TYP) — — — <br />BELOW INLET GRATE DEVICE STORMWATER MINIMUM REQUIREMENTS. <br />n ° �""S' b a RECTANGULAR GRATE SHOWN — <br />o DATE: MARCH, 2017 <br />a <br />o <br />DESIGN: JNM <br />���,\ [ 1 I—III•—�.i I�1—,III— . I 1-_ . � 111=={ ! I-1 I I —,I I h—I i 1-i � \ <br />FILTERED1=_ CONSTRUCTION: DRAWN: AFDC <br />o WATER " �fi I—{ I I-1 I I —I 1 I� 1[=I I I 1=11 I—III=i I I I I 1=111— 11=17^I I i ` 1, BUILD AND VEGETATE RAIN GARDEN AS EARLY -AS CHECKED: <br />o�i/�SIT% �-"_ / POSSIBLE TO ESTABLISH PLANTINGS BEFORE <br />o LL \\ }_I I=11.1-1 I .M —I! 1=—I I 1=1! 1—I I= �i=� t i f I=1!_ EXCAVATE AT STABLE DIRECTING STORMWPiTER RUNOFF TO IT, REVISION <br />NATIVE V SOILPE E FOR NUMBER: <br />2. INFILTRATION AREAS THE AREA OF THE R41N <br />p 5" MIN \/� GARDEN AS DEFINED BYTHE TOP ELEVATION OF THE <br />7. <br />d �' / FACILITY} SHALL BE FENCED OFF FROM THE FIRST DAY SCALE: AS NOTED <br />II �j y / OF EARTH MOVING UNTIL PROJECT COMPLETION TO <br />a- OVERFLOW BYPASS 1/2"-3/8" WASHED GRAVE! `� /` AMENDED PLANTING 501E PREVENT COMP ACTION OF THE SUBGRADE, DIRT man <br />}_ v \ TRACKING ONTO ANY LAYER OFTHE FACILITY AND <br />A? � - � - - - BELOW INLET GRATE DEVICE � � (TYP) CLEAN COARSE SAND - • ,. � . � w � STOCKPILING OF'CONSTRUCTION MATERIALS THAT � - - PROJECT NUMBER: <br />U . P p <br />•L a Q' Q (WSDOT STD SPEC 9-03.13) '` •\ �� \�/�`� ��i . � / °° \ MAY CLOG THE SURFACE. e � y� <br />Q Q o UNIFORMLYGRADED 6"MIN ��� /� TYPE 1-L CB WITH BEEHIVE GRATE 3; DURING EXCAVATION OF NATIVE SOILS TOTH£ RMCAOOOO-0009 <br />o. MIN SUMP DEPTH <br />STORAGE ROCK BOTTOM OF THE FACILITY, RAINFALL MAY CAUSE <br />m m D D P (WSDOT STD SPEC 9-0112(5) . NON=PERFORATED OVERFLOW FINES TO CLOG THE SURFACE OF THE FACILITY: IF THE DRAWING FILE: <br />p p o o PIPE,DIRECTED TO APPROVED DISPOSAL POINT <br />OR EQUIVALENT) NATIVE SOIL HAS BEEN EXPOSED TO RAINFALL, HAND <br />ISOMETRIC VIEW RAKE THE SURFACE TO A DEPTH OF 3" TO RESTORE Ec—IM-•004—RMCA0009.dwg <br />g UNDISTURBED"NATIVE 3" DEPTH 3/4" DRAIN ROCK, OPT INFILTRATION CAPACITY. <br />Q SECTION VIEW SUBGRADE COMPACTED NATIVE SUBGRADE, 4. DURING AREA DRAIN INSTALLATION, DISTURB NATIVE SHEET NO. <br />C^11 5 AS LITTLE AS POSSIBLE <br />r 0 <br />co <br />r <br />O N <br />N � <br />ze)4 <br />v <br />ta0 <br />1 <br />6" PERFORATED PVC PIPE, <br />STORM DRAIN INLET PROTECTION 5=0.0000 <br />REF: WSDOT STD PLAN 1-40.20-00 RAIN GARDEN WITH UNDERDRAIN C41 <br />N0 SCALE <br />BASED ON C.O.E. STD. DWG . 427 OF 4 . <br />NO SCALE. <br />