Laserfiche WebLink
I <br />: s• _a 1 d , r� t� 1 ma <br />t <br />1/8II_11 ®II <br />0 4' S' <br />0 <br />16' 3 2' <br />GENERAL : <br />(:c SEE SHEET AO.1 & A0.2 FOR ADDITIONAL GENERAL NOTES <br />j <br />® THE CONTRACTOR SHALL. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY <br />THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS THAT MIGHT <br />ARISE. <br />1. FOR METAL STUD SIZES AND SPACING SEE LIMITING WALL HEIGHT TABLE <br />L/240 <br />2. ALL WALL STUDS TO BE 3-5/6", U.O.N. <br />3. SEE KEYNOTE INFORMATION FOR ANY REQUIRED INSULATION. <br />4. CONTRACTOR SHALL PROVIDE RECORD DOCUMENTS AND PROVIDE SAID <br />DOCUMENTATION TO TENANT CONSTRUCTION COORDINATOR OR ARCHITECT <br />UPON COMPLETION. <br />5. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS (IF ANY) AND NOTIFY <br />ARCHITECT OF ANY DISCREPANCIES. <br />6. CONTRACTOR TO INCLUDE ALL FLOOR PREPARATIONS IN BASE BID. <br />7. ALL DRYWALL CORNERS AND COLUMN EDGES TO BE FINISHED WITH <br />CORNER "L" BEAD. ALL EXPOSED EDGES TO BE FINISHED WITH METAL <br />TRIM. <br />B. INTERIOR GYPSUM BOARD WALL SHALL CONFORM TO ICC REPORT <br />ESR©1 33. <br />-O <br />83 <br />-O <br />i y ;°' j IJ <br />I a I 1 a <br />PROVIDE NEW BACKING SUPPORT BEHIND WALL —MOUNTED <br />EQUIPMENT LOCATIONS. SEE <br />4 <br />A6.1 <br />PROVIDE NEW UPPER & LOWER CABINETRY WITH DRAWERS, BACK <br />SPLASH AND SINGLE —BASIN STAINLESS STEEL SINK WITH FAUCET. <br />TENANT PROVIDED COFFEE MAKER, GC TO PROVIDE WATERLINE, IF <br />REQUIRED VERIFY. <br />4 NEW REFRIGERATOR, TO BE PROVIDED AND INSTALLED BY TENANT,GC <br />TO PROVIDE WATERLINE, IF REQUIRED VERIFY. <br />5 EXISTING WALL HUNG FIRE EXTINGUISHER TO REMAIN. <br />6 EXISTING SEMI --RECESSED FIRE EXTINGUISHER CABINET WITH FIRE <br />EXTINGUISHER TO REMAIN. <br />7 EXISTING MILLWORK TO REMAIN. <br />EXISTING CONSTRUCTION TO REMAIN <br />EXISTING 1—HR RATED PARTITION TO REMAIN <br />C NEW PARTITION TO UNDERSIDE OF CEILING <br />A6.1 <br />DOOR SCHEDULE <br />DOOR & FRAME: <br />X SUITE STANDARD DOORS ARE AND SHALL BE SOLID CORE WOOD TO MATCH <br />EXISTING BUILDING STANDARD, U.O.N.. ALL DOORS TO BE PRE —MACHINED <br />FOR CYLINDRICAL HARDWARE AND FREE FROM DAMAGE AND IRREGULARITIES. <br />FRAMES SHALL MATCH BUILDING STANDARD, <br />A PROVIDE AND INSTALL NEW DOOR AND FRAME ASSEMBLY TO MATCH SUITE <br />STANDARD LISTED ABOVE. <br />B EXISTING DOOR AND FRAME ASSEMBLY TO REMAIN. <br />X DOOR HARDWARE SHALL BE AN ACCESSIBLE LEVER STYLE. HARDWARE TO <br />MATCH EXISTING BUILDING STANDARD, <br />1 PROVIDE AND INSTALL NEW PASSAGE SET HARDWARE SET TO MATCH <br />SPECIFICATIONS LISTED ABOVE. <br />2 PROVIDE AND INSTALL NEW PRIVACY LOCK SET HARDWARE SET TO MATCH <br />SPECIFICATIONS LISTED ABOVE. PROVIDE OCCUPANCY INDICATOR. <br />3 EXISTING DOOR HARDWARE TO REMAIN. <br />UJI <br />0 <br />a� <br />0 <br />o� <br />�® <br />O <br />ON <br />a� <br />�4 <br />°4 <br />� <br />So <br />� <br />11 <br />N <br />bA °u <br />® a <br />.E> <br />x <br />Ix <br />Z <br />a <br />0 <br />z <br />W <br />2 <br />W <br />ui <br />z <br />0 <br />c� <br />M <br />af <br />0 <br />x <br />CL <br />m <br />M <br />0 <br />U <br />a <br />M <br />W <br />0 <br />p <br />0 <br />z <br />i-- <br />g <br />0 <br />x <br />m <br />W <br />J <br />J <br />z <br />c� <br />r <br />z <br />a <br />J <br />x <br />an <br />W <br />z <br />0 <br />C� <br />I.e i <br />z <br />Iz <br />W <br />Of <br />Ld <br />uj <br />s <br />r <br />z <br />W <br />0 <br />m <br />r <br />W <br />W <br />X <br />LJ <br />Y <br />m <br />L <br />W <br />r <br />0 <br />z <br />z <br />0 <br />V <br />D <br />u <br />z <br />a <br />W <br />z <br />ca <br />0 <br />0, <br />a <br />W <br />LL <br />0 <br />h— <br />m <br />0 <br />0 <br />0 <br />z <br />a <br />r <br />W <br />W <br />a. <br />W <br />F <br />I®' <br />Lai <br />Of <br />z <br />0 <br />r <br />Q <br />