Permit* B2103-090 <br />Site Address: 1415 75TH ST SW <br />GENERAL NOTES: <br />1. ALL WORK SHALL COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE. <br />2. ELECTRICAL WORK SHALL COMPLY WITH THE 2018 NATIONAL ELECTRICAL CODE AS AMENDED BY THE LOCAL MUNICIPALITY. <br />3. VERIFY DIMENSIONS AND CONDITIONS IN FIELD. NOTIFY ARCHITECT IF NOT AS SHOWN. <br />4. SEE STRUCTURAL FOR ADDITIONAL NOTES AND SYMBOLS. <br />5. EACH CONTRACTOR IS RESPONSIBLE TO REVIEW THE MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND <br />PATCHING WORK BEYOND THE LIMITS OF THE PROJECT SHOWN ON THE ARCHITECTURAL DRAWINGS. <br />6. EACH CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES FOR ALL OPENINGS FOR DUCTS, PIPES, CONDUIT, CABINETS <br />AND EQUIPMENT AND SHALL VEIFY SIZE AND LOCATION. <br />7. EACH CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT FURNISHED AND INSTALLED BY HIMSELF OR <br />OTHERS. <br />8. CONTRACTOR FURNISHED ITEMS SHALL BE SUPPLIED WITH REQUIRED MECHANICAL AND ELECTRICAL SERVICES TO <br />PROVIDE OPERATION OF ITEMS FURNISHED. <br />9. ROOM FINISH SCHEDULE SHALL NOT BE TAKEN AS COMPLETE SPECIFICATION FOR ALL INTERIOR ROOM MATERIALS; <br />HOWEVER, IT SHALL BE BINDING TO THE EXTENT OF THE MATERIAL IT DOES SPECIFY. THE CONTRACTOR SHALL CHECK THE <br />SCHEDULE WITH THE SPECIFICATIONS AND DRAWINGS FOR OTHER MATERIALS NOT COVERED BY THE SCHEDULE. <br />10. WINDOW AND DOOR NUMBERS SHOWN ON DRAWINGS ARE FOR CONSTRUCTION PURPOSES ONLY. <br />11. STUDS ARE TO EXTEND TO UNDERSIDE OF STRUCTURE. WHERE THEY CANNOT DO SO, DUE TO INTERFERENCES WITH <br />DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION. <br />12. THE CARPENTRY CONTRACTOR SHALL BUILD IN ALL ROUGH BUCKS FOR GRILLES, REGISTERS, ETC. WHERE REQUIRED. <br />13. ALL PIPING, CONDUIT, DUCTS, ETC. SHALL BE FURRED -IN AT ALL FINISH ROOMS. <br />It ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL HAVE A PRESERVATIVE TREATMENT. <br />15. PLACE NO MAINS, PIPING, CONDUIT OR OBSTRUCTIONS OF ANY KIND SO AS TO IMPAIR GIVEN CEILING HEIGHTS AND <br />CLEARANCES. <br />16. PROVIDE BLOCKINGIBACKING FOR ALL WALL HUNG CABINETS, FIXTURES OR EQUIPMENT. ALSO PROVIDE <br />BLOCKINGIBACKING AT BATHROOM FOR GRAB BAR INSTALLATION. <br />17. ALL SURFACE ATTACHED LADDERS USED ONLY TO ATTEND EQUIPMENT SHALL COMPLY WITH O.S.H.A. REGULATIONS. <br />18. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED, THE CONTRACTOR IS TO REPAIR TO SAME AND TO MATCH <br />ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS <br />CORNERS, CEILING LINES, TOP OF BASE, ETC. <br />19. DIMENSIONS, IN GENERAL, ARE: <br />A. AT INTERIOR WALL STUD FACE TO STUD FACE OF WALUPARTITION <br />S. AT CONCRETE WALLS TO THE FACE OF CONCRETE. <br />C. AT MASONRY WALLS TO THE FACE OF MASONR (NOMINAL). <br />D. AT EXISTING FINISHES TO THE FACE OF FINISH. <br />E. COLUMN TO COLUMN CENTERLINE OR COLUMN CENTERLINE TO FACE OF STUD. <br />F. <br />20. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL BE SIX INCHES (4-MIN) FROM THE FACE OF <br />INTERSECTING WALL TO EDGE OF DOOR OPENING. <br />21. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS PRIOR TO CONSTRUCTION. NOTIFY THE ARCHITECT OF ANY <br />DISCREPANCIES. IF WORK IS STARTED PRIOR TO VERIFICATION, THE GENERAL CONTRACTORIBUILDER AND <br />SUBCONTRACTOR PROCEED AT THEIR OWN RISK. <br />22. MATERIALS: SHOWER FLOOR AND WALLS WITH INSTALLED SHOWER HEADS OR IN SHOWER COMPARTMENTS SHALL BE <br />FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 7 <br />FEET ABOVE FLOOR FINISH. <br />23. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. <br />24. STRUCTURAL WOOD MEMBERS IN CONTACT WITH EARTH OR CONCRETE LOCATED NEARER THAN 6 INCHES TO THE EARTH <br />SHALL BE OF PRESERVATIVE TREATED WOOD. <br />25. WATER RESISTANCE: THE EXTERIOR WALL ENVELOPE SHALL BE CONSTRUCTED IN A MANNER THAT PREVENTS THE <br />ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE <br />EXTERIOR VENEER AND A MEANS OF DRAINING TO THE EXTERIOR WATER THAT ENTERS THE ASSEMBLY. PROTECTION <br />AGAINST CONDENSATION IN THE EXTERIOR WALL ASSEMBLY SHALL BE PROVIDED. <br />26. WATER RESISTANT WALLBOARD IS TO BE USED AS BASE FOR TILE INSTALLATION AT FLOOR OR WALL PANELS IN SHOWERS <br />ANDIOR ENCLOSURES OF WATER CLOSET ROOMS, EVEN IF IT IS APPLIED OVER VAPOR BARRIER. <br />27. HAZARDS: SAFETY GLAZING IS REQUIRED IN ALL DOORS, RAILINGS AND SHOWER ENCLOSURES. ANY GLAZING WITHIN 24 <br />INCHES OF A DOOR OPENING AND WITHIN 60 INCHES OF THE FLOOR SHALL BE SAFETY GLAZING. FIXED GLAZING GREATER <br />THAN 9 SQUARE FEET IN AREA AND WITHIN 18 INCHES OF THE FLOOR IS ALSO TO BE SAFETY GLAZING. <br />vie � <br />EMERGENCY LIGHT _CPET= ### - <br />EGRESS LINE <br />EATD= ### <br />(WITH COMMON PATH OF <br />EXIT <br />EXIT SIGN,(WBUGEYES <br />EGRESS TRAVEL (CPET) & <br />OR INTERNAL LIGHTS) <br />ACCESST <br />IITANCE RAVEL <br />EXIT EXIT SIGN,(DIRECTIONAL) <br />-- -- - - - - <br />#HOUR SEPARATION <br />EXIT SIGN <br />(WITH EGRESS / BUGEYES / =y <br />EXISTING WALL <br />'- INTERNAL LIGHTING) <br />EMERGENCY LIGHTING--r�1-1-^ <br />INTERCONNECTED <br />NEW STOREFRONT / <br />POLYCARBONATE WALL <br />WITH BATTERY BACKUP <br />F-1: OCCUPANCY <br />FIRE EXTINGUISHER <br />(WITH CABINET) <br />B: OCCUPANCY <br />FEC <br />RESTROOMS / SHOWERS <br />NOTE: <br />1. EXIT SIGNS SHALL BE ILLUMINATED 2417 <br />2. PROVIDE 90MIN BACKUP BATTERY POWER SUPPLY TO ALL EXIT & EMERGENCY SIGNS/LIGHTS. <br />3. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE <br />BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED (2016 IBC-SECT.1006.1) <br />4. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE AT THE <br />FLOOR LEVEL (2015 IBC-SECT.1006.2) <br />VICINITY MAP <br />EVERETT FIRE DEPT. REVIEW <br />qd APPROVED <br />Q APPROYEO WITM NOTED <br />C1 REVME AND <br />a REJE&M <br />SEE A1iAICNEO OW WW/NMDOUT <br />The issuance of a pe mit shall not <br />be construed as a to violate, <br />cancel or $0 abide provision of <br />the Everett Fka or other <br />applicsWe ropulat or laws. The <br />issuance ofa perm MseO on <br />cony dOcumeMs and Other <br />data shall riot prevent the Fire Code <br />Offical fmrn requiring the correction <br />of errors. <br />By -_Date• 13 Z <br />APPROVF-U <br />PUBLI WORKS D PARTMENT <br />BY <br />DATE 3 <br />CITY OF EVERETT REVIEWED FOR PERMIT <br />APPROVED <br />PLANNING & COMMUNE <br />DEVE PMENT DEP . <br />BY <br />DATE C )I <br />A) PROJECT DATA (2018 IBC TABLE: 504.3, 504.4, 506.2, 507.4 <br />OCCUPANCY GROUPS: B, F-1 <br />CONSTRUCTION TYPE: V-B, UNLIMITED AREA <br />SPRINKLED: YES <br />ALLOWABLE SIDE YARD I PUBLIC WAYS: 60' WIDE EXISTING BLDG HEIGHT: 3W - 0" <br />ALLOWABLE STORIES:1 EXISTING STORIES: 1 <br />ALLOWABLE AREA: UNLIMITED EXISTING BUILDING AREA: 156,925 SY <br />TENANT IMPROVEMENT AREA: 24,074 SY <br />B) ALLOWABLEIACTUAL BUILDING AREA CALCULATIONS 2018 IBC TABLE 507.4 <br />EXISTING AREA: 156,925 S.F <br />ALLOWED AREA: UNLIMITED <br />THE PROPOSED TENANT IPROVEMENT AREA MEETS CODE FOR ALLOWABLE FLOOR AREA. <br />C) FIRE RESISTANCE REQUIREMENTS 2018 IBC TABLE 602, 705.8. 508.4 <br />1. B & F-1, WITH TYPE V-B CONSTRUCTION WILL HAVE NON -SEPARATION OCCUPANCIES. <br />2. THE REQUIRED FIRE RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE <br />SEPARATION DISTANCE GREATER THAN 10FT SHALL BE RATED FOR EXPOSURE TO FIRE <br />FROM THE INSIDE. (IBC SECTION 705.5) <br />3. FIRE RATING - EXTERIOR WALLS & PROTECTED/UNPROTECTED OPENINGS (TABLE 602, 705.8) <br />NORTH EAST WEST & SOUTH Elevations are Greater Than 301L to PT -Line. <br />Therefore They are Allowed UNLIMITED UNPROTECTED OPENINGS, and 0-Hr Rated Walls <br />D) OCCUPANCY LOAD CALC'S 20181BC TABLE 1004.5) <br />• OCCUPANCY: B, F-1 <br />(B) OCCUPANT LOAD: (28,558.171150) =190 <br />(F-1) OCCUPANT LOAD: (125239.561100) =1252 <br />(S) OCCUPANT LOAD: (53.631100) =1 <br />• TOTAL OCCUPANCY:1443 <br />E) MINIMUM NUMBER OF EXITS (MEANS OF EGRESS) (2018 IBC TABLE 1006.3.2.1 <br />OCCUPANCY :B , F-1 <br />MINIMUM EXITS PER STORY: (OL OF MORE THAN 1000) = 4 <br />• THE OCCUPAND LOAD (OL) OF THE BUILDING =1443 <br />• TWELVE (12) EXITS HAVE BEEN PROVIDED. <br />F) MINIMUM PLUMBING FACILITIES CALC'S (2018 IBC TABLE 2902.1) <br />WATER CLOSETS (TOILETS) REQ. =1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE <br />REMAINDER EXCEEDING 50 (MALE & FEMALE) <br />LAVATORIES (SINKS) REQ. =1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER <br />EXCEEDING 80 (MALE & FEMALE) <br />• MALE TOILETS REQ.: (50125 = 2,110150= 2) = 4 <br />• MALE TOILETS PROVIDED: 8 <br />• MALE SINKS REQ. = (80140 = 2, 80180=1) = 3 <br />• MALE SINKS PROVIDED: DIY OF EVERE T <br />MALE SINKS PROVIDED =1 <br />(2) BRADLEY FOUNTAIN 4' 6" DiA. =108" 130" = 4 SINKS REVIEWED FOR PERMIT <br />TOTAL MALE SINKS PROVIDED: 5 <br />• FEMALE TOILETS REQ. = (50125 = 2,110150= 2) = 4 <br />• FEMALE TOILETS PROVIDED:10 TN+ SE DOCUMENTS HAVE NO F BEEN <br />APPROVED FOR THE ISSUANCE OF <br />• FEMALE SINKS REQ. = (80I40 = 2, 80180=1) = 3 PUBLIC WORKS,1,4ECHANI�AL, FIRE <br />• FEMALE SINKS PROVIDED: 5 SUPPRESSION, ELECTRICAL O <br />PLUMBING PERMITS. <br />• ALL GENDER TOILET REQ. = 0 <br />• ALL GENDER TOILET PROVIDED:1 <br />Additional Permits Are Required <br />For This Project To Includes <br />Plumbing Sprinkler <br />Mechanical - Fire Alarm <br />Electrical <br />A 0.0 <br />COVER SHEET <br />A 1.0 <br />ARCHITECTURAL SITE PLAN <br />A 1.1 <br />MAIN FLOOR PLAN - EXISTING & DI <br />A 1.2 <br />MAIN FLOOR PLAN - EXISTING & DI <br />A 2.0 <br />KEY FLOOR PLAN - TI <br />A 2.1 <br />MAIN FLOOR PLAN - TI <br />A 2.2 <br />MAIN FLOOR & ENLARGED PLANS - TI <br />A 2.3 <br />CEILING PLAN - TI <br />A 3.0 <br />ELEVATIONS <br />A 3.1 <br />ELEVATIONS <br />A 3.2 <br />INTERIOR ELEVATIONS <br />A 3.3 <br />INTERIOR ELEVATIONS <br />A 3.4 <br />INTERIOR ELEVATIONS <br />A 4.0 <br />SECTIONS <br />A 5.0 <br />DOOR & FINISH SCHEDULES <br />S 1.0 <br />GENERAL STRUCTURAL NOTES <br />S 2.0 <br />DEMISHING WALL PLAN <br />S 2.1 <br />DETAILS <br />S 3.0 <br />DETAILS <br />PROJECT DESCRIPTION: <br />MODIFICATION TO THE EXISTING BUILDING LOCATED AT 1415 75t' DID SET 3115/2021 <br />AVENUE S.W in EVERETT, WASHINGTON. <br />JURISDICTION: CITY OF EVERETT <br />ADDRESS: 1415 75TH ST SW, WA. 98203 <br />ZONING: INDUSTRIAL (LI.2) <br />PARCEL M 28041100101000 <br />CODES: 2018 (IBC, IEBC, UPC, IFC, IMC, WSEC) <br />City of Everett Municiple Code <br />ICCIANSI Al17.1-2018 <br />2018 NFPA13, 2018 NFPA72 <br />SITE AREAS: 9.59 ACRE(S) (417,740A S.F) <br />BLDG. AREA: <br />TOTAL EXIST. BUILDING AREA=156,925 S.F <br />TENANT IMPROVENT AREA = 24,074 S.F <br />SETBACKS (EMC TABLE 14.48.1) <br />FRONT: 211' <br />BACK: 89' <br />SIDE: 93' <br />SIDE: 60' <br />PARKING: (EMC TABLE 34-1) <br />:.1 PER 400 S.F (OFFICE) = 24,0741400 = 60 SPACES <br />: 1 PER 750 S.F (LIGHT INDUSTRIAL) <br />(156,925 - 24,074= 132,851)1750 =177 SPACES <br />PARKING REQ.: 237 SPACES <br />PARKING PROVIDED <br />REGULAR PARKING: 242 <br />COMPACT PARKING: 0 <br />ADA PARKING :4 <br />TOTAL PARKING: 246 <br />MAXIMUM HEIGHT: 35 FT <br />ACTUAL BLDG. HEIGHT: 30 FT <br />OCCUPANCY GROUP: B, F-1 <br />CONSTRUCTION TYPE: V-B, UNLIMITED AREA <br />SPRINKLED: YES <br />LEGAL DESCRIPTION: <br />SEC 11 TWP 28 RGE 04 LOT A OF B.S.P. NO 2-88 REC VOL 10F B.S.P: S <br />PG 105 AF NO 8804065001 BEING A PTN OF SE1/4 NE114 AMENDED PER <br />BSP AMENDMENT REC AFN 200102225001 <br />Owner: <br />EVERETT TECH PARK II <br />Tenant: <br />HELION ENERGY <br />App. Date: <br />3/30/2021 <br />Proposed Use: <br />COMMERCIAL ALTERATIONS <br />Description: <br />TENANT IMPROVEMENT- MOD'S TO THE <br />INTERIOR OF EXTG BLDG, WAREHOUSETO <br />OFFICE & LIGHT INDUSTRIAL <br />Reviewed By ' <br />-_/ Date: �� ✓ ,/ <br />OfFice Set <br />Job Site Set Fire/Planning Set <br />PROJECT TEAM: <br />OWNER <br />HELION ENERGY <br />1416 75TH ST. SW. EVERETT, WA 98203 <br />ANTHONY PANCOTTI <br />ARCHITECT <br />2812 ARCHITECTURE <br />2812 COLBY AVE. EVERETT, WA 98201 <br />SIMON SIMON (426.252.2163) <br />STRUCTURAL <br />QUANTUM CONSULTING ENGINEERS <br />1511 3RD EVE. SUITE 323, SEATTLE, WA <br />JOHN RILEY (206.957.3906) <br />SEPARATE SUBMITTAL: <br />• FIRE ALARM <br />• MECHANICAL <br />• ELECTRICAL <br />• PLUMBING <br />NOTE: <br />ALL SEPARATE SUBMITTALS SHALL BE SUBMITTED TO THE <br />ARCHITECT FOR REVIEW & APPROVAL PRIOR TO PERMIT SUBMISSION <br />v <br />i <br />Qa'�L <br />.s� a Cl <br />N <br />ty V- <br />N <br />L � <br />N <br />N Ill <br />u� <br />J <br />Q <br />U <br />0 <br />Z <br />w <br />C' <br />C o <br />O <br />Z <br />wCD <br />W <br />cr Q <br />Z <br />co <br />® <br />Z <br />J <br />Ln w <br />�� <br />w <br />H <br />_ <br />r W <br />W <br />W <br />N <br />Ce <br />W <br />O <br />0 <br />20-4247 <br />