11/16/2017 12:57:03 PM
<br />PROJECT DESCRIPTION PROJECT TEAM
<br />20,116 SF WAREHOUSE ADDITION FOR THE STORAGE OF BUILDING OWNER ARCHITECT
<br />MATERIALS TO EXISTING MANUFACTURING FACILITY. AD SYSTEMS FISHER CONSTRUCTION GROUP,
<br />2201 100 ST. SW INC.
<br />PROJECT INFORMATION: EVERETT, WA 98204 625 FISHER LANE
<br />2201 100TH ST. SW (425) 374-1360 BURLINGTON, WA 98233
<br />EVERETT, WA 98204 CONTACT: GREG GOLDFINCH (360) 757-5676
<br />GREG.GOLDFINCH@SPECADSYSTEMS.COM CONTACT: SETH BURWASH
<br />PARCEL NUMBER: SJB@FISHERCGI.COM
<br />2804140030000
<br />28041400300900
<br />GENERAL CONTRACTOR STRUCTURAL
<br />FISHER CONSTRUCTION GROUP, FISHER CONSTRUCTION GROUP, INC.
<br />SITE: INC. 625 FISHER LANE
<br />AREA OF SITE: 625 FISHER LANE BURLINGTON, WA 98233
<br />181,789 SF BURLINGTON, WA 98233 (360) 757-5694
<br />(360) 757-4094 CONTACT: ARTHUR FELLOWS
<br />PLANNING ZONE: AGF@FISHERCGI.COM
<br />M-M - BUSINESS PARK CIVIL FIRE PROTECTION
<br />LOT COVERAGE/SETBACKS: NAVIX ENGINEERING N/A
<br />MAX LOT COVEREGE BY BUILDING = N/A 11400 SE 8TH STREET, SUITE 345
<br />SETBACKS: FRONT/REAR 20', SIDE - STREET 15', SIDE - INTERIOR 10' BELLEVUE, WA 98004
<br />(425) 458-7900
<br />CONTACT: JOE TAFFLIN
<br />FLOOD ZONE: N/A JOE@NAVIXENG.COM
<br />ELECTRICAL MECHANICAL
<br />APPLIC /� BLE CODES KRASSIN ELECTRIC INC. NIA
<br />M 2809 CEDAR ST.
<br />EVERETT, WA 98201
<br />DATE/NAME (425) 339-2391
<br />AUTOMATIC FIRE DETECTION & SUPPRESSION SYSTEMS ORIDANCE NO. 1902-92 CONTACT: CRAIG KRASSIN
<br />2015 INTERNATIONAL BUILDING CODE & WAC 51-50 CRAIG.KRASSIN@COMCAST.NET
<br />2015 EXISITNG BUILDING CODE & WAC 51-50
<br />2009 ANSI 117.1 & WAC 51-50-005
<br />2015 INTERNATIONAL FIRE CODE & WAC 51-54
<br />2015 INTERNATIONAL MECHANICAL CODE & WAC 51-52
<br />2014 NATIONAL ELECTRICAL CODE & WAC 296-46B-010
<br />2015 UNIFORM PLUMBING CODE & WAC 51-56 & 51-57
<br />2015 WASHINGTON STATE ENERGY CODE COMMERICAL, WAC 51-11
<br />2015 CITY OF EVERETT DESIGN & CONSTRUCTION STANDARDS & SPECIFICATIONS
<br />EVERETT STORMWATER MANAGEMENT MANUAL
<br />EVERETT MUNICIPAL CODE, TITLE 19 ZONING
<br />SITE PLANNING BUILDING CODE REVIEW
<br />AREA OF IMPERVIOUS SURFACES: CONSTRUCTION TYPE: (IBC 2015) V-B
<br />TOTAL EXISTING BUILDINGS 28,381 SF (15.4%) FIRE RESISTIVE CONSTRUCTION: (IBC CHATPER 6) RATING
<br />TOTAL EXISTING PAVING 102,850 SF (60.0%) PRIMARY STRUCTURAL FRAME 0 HRS
<br />TOTAL EXISTING IMPERVIOUS SURFACE 131,231 SF (75.4%) BEARING WALLS - EXTERIOR 0 HRS
<br />BEARING WALLS - INTERIOR 0 HRS
<br />PROPOSED NEW BUILDINGS 21,073 SF NONBEARING WALLS - EXTERIOR 0 HRS
<br />PROPOSED NEW PAVING (NET) -6,217 SF NONBEARING WALLS - INTERIOR 0 HRS
<br />TOTAL PROPOSED IMPERVIOUS SURFACE (NET) 137,288 SF (70.8%) FLOOR CONSTRUCTION 0 HRS
<br />ROOF CONSTRUCTION 0 HRS
<br />TOTAL SITE IMPERVIOUS SURFACE 137,288 SF (70.8%)
<br />FIRE PROTECTION:
<br />AREA OF PERVIOUS SURFACES FIRE SPRINKLERS (NFPA 13) YES
<br />TOTAL AREA 46,535 SF (25.3%) FIRE ALARM (NFPA 72) YES
<br />PORTABLE FIRE EXTINGUISHERS YES
<br />LANDSCAPING REQUIREMENTS:
<br />TOTAL AREA 1,920 SF ALLOWABLE AREAS: (IBC TABLE 506.2)
<br />VB - B BUSINESS - S1 = 36,000 SF PER FLOOR
<br />PARKING: VB - F-1 FACTORY - S1 = 34,000 SF
<br />VB - S-1 STORAGE - S1 = 36,000 SF
<br />TOTAL NUMBER REQUIRED:
<br />69 PARKING SPACES ) 3 ADA PARKING SPACES ( OCCUPANCY GROUP: IBC 302 GROUP GROSS AREA
<br />OFFICE - FIRST FLOOR (EXIST) B 2,347 SF
<br />TOTAL NUMBER OF PARKING STALLS PROVIDED: OFFICE - SECOND FLOOR (EXIST) B 2,175 SF
<br />80 PARKING SPACES E FACTORY (EXIST) 3 ADA PARKING SPACES ( ) F-1 26,034 SF
<br />FACTORY F-1 1,072 SF
<br />27,106SF
<br />PLUMBING STORAGE S-1 20,162 SF
<br />OCCUPANY (TABLE 1004.1.2) ALL,.AREAS WITHIN TABLE._506.2 ALLOWANCES.,
<br />.� .�
<br />OCCUPANCY -DESCRIPTION TOTAL AREA AREA/OCC. OCC. LOAD UNLIMITED BUILDING AREA 507.4
<br />SPRINKLERED, TWO-STORY BUILDING OF GROUP B, F AND S NO MORE THAN TWO
<br />B - OFFICE 4,522 SF 100 46 STORIES ABOVE GRADE SHALL NOT BE LIMITED WHERE THE BUILDING IS EQUIPED ,
<br />F-1 -FACTORY 27,106 SF 100 272 THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
<br />S-1 -STORAGE 20,162 SF 500 41 SECTION 903.3.1.1 AND IS SURROUNDED AND ADJOINED BY PUBLIC WAYS OR
<br />359 YARDS NOT LESS THAN 60 FEE IN WIDTH.
<br />PLUMBING (TABLE 2902.1) ..........
<br />REQUIRED SEPARATION. (IBC TABLE 508.4)
<br />OCCUPANCY - DESCRIPTION REQUIRED W.0 REQUIRED LAV B TO F-1 = NO SEPARATION REQUIRED
<br />B - OFFICE 2 2 F-1 TO S-1 = NO SEPARATION REQUIRED
<br />F-1 - FACTORY 3 3 OCCUPANCY: (IBC TABLE 1004.1.2TOTAL AREA AREA/OCC OCC LOAD
<br />S-1 - STORAGE 1 1 B - OFFICE 4,522 100 46
<br />6 6 F-1 - FACTORY 27,106 100 272
<br />PROVIDED 13 8 S-1 - STORAGE 20,162 500 41
<br />SYMBOLLEGEND PACKET SUBMITTALS
<br />1. PUBLICK WORKS DATE: 2017-09-25
<br />NUMBER A. SITE DESIGN
<br />TYPE mxx WINDOW SYMBOL B. UTILITIES
<br />(VNUMBER
<br />HARDWARE TYPE C. CIVIL DESIGN
<br />DOORSYMBOL NUMBER D. ARCHITECTURAL DESIGN
<br />o� SHEET DETAIL CALLOUT E. FOOTING AND FOUNDATIONS
<br />F. LIGHTING LAYOUT
<br />WALL
<br />TYPE WALL SYMBOL EXTERIOR ELEVATION 2. DEFERRED SUBMITTALS DATE: TBD
<br />x Ax.x
<br />SHEET A. FIRE PROTECTION
<br />BUILDING SECTION A B. MECHANICAL DESIGN
<br />Axx Axx <X.X�>
<br />SHEET INTERIOR ELEVATION C. ELECTRICAL DESIGN
<br />D. STEEL BUILDING FRAMES
<br />x T.O.xxx ELEVATION TARGET
<br />Axx WALL SECTION X.R.
<br />ANEW PROJECT FOR:
<br />4 . r-
<br />Alk ']mot-'7lrmmq i A �-
<br />WAREHOUSE EXPANSION
<br />EVERETT, WA
<br />VICINITY PLAN (NTS)
<br />DRAWING INDEX
<br />SHEET
<br />NUMBER
<br />SHEET NAME
<br />REVISION
<br />DESCRIPTION
<br />GENERAL - REV 1 - 2017-10-25
<br />AO.0
<br />COVER SHEET
<br />PERMIT SET
<br />AO.1
<br />CODE REVIEW
<br />PERMIT SET
<br />AO.2
<br />ANSI DETAILS
<br />PERMIT SET
<br />AO.3
<br />ANSI DETAILS
<br />PERMIT SET
<br />AO.4
<br />ANSI DETAILS
<br />PERMIT SET
<br />CIVIL - REV 0 - 2017-09-13
<br />CV-1
<br />COVER SHEET
<br />PERMIT SET
<br />Sheet 1 of 1
<br />A.S.P.I. TOPOGRAPHIC SURVEY
<br />PERMIT SET
<br />D-1.0
<br />T.E.S.C. AND CIVIL SITE DEMOLITION PLAN
<br />PERMIT SET
<br />D-1.1
<br />T.E.S.C. DETAILS
<br />PERMIT SET
<br />C-1.0
<br />SITE PLAN
<br />PERMIT SET
<br />C-2.0
<br />GRADING AND DRAINAGE PLAN
<br />PERMIT SET
<br />C-2.1
<br />GRADING AND DRAINAGE DETAILS
<br />PERMIT SET
<br />C-3.0
<br />UTILITY PLAN
<br />PERMIT SET
<br />APPROVED
<br />PLANNING & COMMUNITY,
<br />EVELOPMENT DEPT.
<br />BY- 9 l
<br />SPRINKLER VALVES AND COMPONENTS
<br />MUST BE MAINTAINED AT 40OF
<br />MINIMUM TEMPERATURE PER NFPA 13
<br />MONITORED AUTOMATIC FIRE
<br />DETECTION SYSTEM REQUIRED
<br />SUPERVISED AUTOMATIC
<br />SPRINKLER SYSTEM REQUIRED
<br />Additional Permits Are Required
<br />For This Project To Include-
<br />------------
<br />Plumbing Sprinkler
<br />= J2D Mechanical Fire Alarm
<br />Electrical
<br />I ° al
<br />PLANNING DEPT. INSPECTION REQUIREDN
<br />PRIOR TO REQUEST FOR FINAL INS
<br />Landscaping ___._Fencing Signs
<br />Environmentally Sensitive Area
<br />`Other
<br />Contact: � IL
<br />(425) 257-8731 exT �
<br />SHEET
<br />NUMBER
<br />SHEET NAME
<br />REVISION
<br />DESCRIPTION
<br />ARCHITECTURAL - REV 1 - 2017-10-25
<br />A1.0
<br />SITE DEMO PLAN
<br />PERMIT SET
<br />A1.1
<br />ARCHITECTURAL SITE PLAN
<br />PERMIT SET
<br />A2.0
<br />FLOOR PLAN
<br />PERMIT SET
<br />A3.0
<br />BUILDING ELEVATIONS
<br />PERMIT SET
<br />A4.0
<br />BUILDING SECTIONS
<br />PERMIT SET
<br />A5.0
<br />WALL SECTIONS
<br />PERMIT SET
<br />A5.1
<br />SECTION DETAILS
<br />PERMIT SET
<br />A7.0
<br />ROOF PLAN
<br />PERMIT SET
<br />A8.0
<br />DOORSM/INDOWS & STAIRS
<br />PERMIT SET
<br />STRUCTURAL - REV 1 - 2017-10-25
<br />S1.0
<br />GENERAL NOTES
<br />PERMIT SET
<br />S1.1
<br />SPECIAL INSPECTIONS
<br />PERMIT SET
<br />S2.1
<br />FOUNDATION PLAN
<br />PERMIT SET
<br />S2.2
<br />FOUNDATION SECTIONS & DETAILS
<br />PERMIT SET
<br />S2.3
<br />BRACE FRAME ELEVATION AND DETAILS
<br />PERMIT SET
<br />S2.4
<br />BRACE FRAME DETAILS
<br />PERMIT SET
<br />S2.5
<br />DETAILS
<br />PERMIT SET
<br />THESE DOCUMENTS HAVE NOT BEEN
<br />ARM CUED FOR THE ISSUANCE OF
<br />PUu;.:C WORKS,MECNANiCA : TIRE
<br />SUPPitCSSION, ELECTRIGA'
<br />Pl 1I"Rtk,4 , PERMITS.
<br />CITY OF EVE.RETT
<br />REVIEWED FOR PERMIT
<br />SHEET
<br />NUMBER
<br />SHEET NAME
<br />REVISION
<br />DESCRIPTION
<br />STEEL BUILDING - REV C - 2017-09-21
<br />G1.01
<br />ANCHOR ROD PLAN
<br />PERMIT SET
<br />ELECTRICAL - REV 0 - 2017-08-23
<br />1 OF 1
<br />BUILDING LIGHTING PLAN
<br />PERMIT SET
<br />Permit#:
<br />B1709-037
<br />Site Address:
<br />2201100TH ST SW
<br />Owner:
<br />AUREUS LLC
<br />Tenant:
<br />[TenName]
<br />App. Date:
<br />9/25/2017
<br />Proposed Use: COMMERCIAL
<br />Description:
<br />PRE-MFG STEEL BUILDING WAREHOUSE
<br />ADDN TO EXISTING MFG FAC
<br />Reviewed B
<br />Date:
<br />Offic
<br />fob Site S t Fire/Planning Set
<br />NOTE:
<br />THIS TITLE SHEET CONTAINS A LIST OF DRAWINGS WHICH COMPRISE A FULL SET OF DRAWINGS FOR THIS PROJECT. ANY CONTRACTOR, SUBCONTRACTOR, VENDOR OR ANY OTHER PERSON
<br />PARTICIPATING IN OR BIDDING ON THIS PROJECT SHALL BE RESPONSIBLE FOR THE INFORMATION CONTAINED IN ANY AND ALL SHEETS OF DRAWINGS AND SPECIFICATIONS. IF ANY PERSON, PARTY
<br />OR ENTITY ELECTS TO SUBMIT BIDS FOR ANY PORTION, OR ALL, OF THIS PROJECT, THAT PERSON, PARTY OR ENTITY SHALL. BE RESPONSIBLE FOR ANY AND ALL INFORMATION CONTAINED IN THESE
<br />DRAWINGS AND SPECIFICATION, INCLUDING, BUT NOT LIMITED TO, ANY SUBSEQUENT ADDENDUMS OR CLARIFICATIONS THAT MAY BE ISSUED.
<br />FISHER
<br />CONSTRUCTION
<br />GROUP
<br />625 Fisher Lane
<br />Burlington, WA 98233
<br />T: 360.757.4094
<br />F: 360.757.4005
<br />www.fishercgi.com
<br />REV DATE
<br />REV 0 2017-09-25
<br />REV 1 2017-10-25
<br />AD SYSTEMS
<br />WAREHOUSE
<br />EXPANSION
<br />2201 100TH ST. SW
<br />Stamp:
<br />Lu F'
<br />v
<br />> p
<br />>
<br />LU
<br />� CD
<br />LU
<br />�UJ
<br />Q0
<br />UJ
<br />Drawing Title:
<br />COVER SHEET
<br />JOB #: 17FO35
<br />Drawing No:
<br />A0e0
<br />PERMIT SET
<br />
|