Laserfiche WebLink
11/16/2017 12:57:10 PM <br />5 <br />PROJECT AREAS NEW <br />NAME <br />AREA <br />BUILDING <br />28381 SF <br />LANDSCAPING <br />45647 SF <br />NEW BUILDING <br />21234 SF <br />PAVEMENT . <br />86527 SF <br />181789 SF <br />LOT COVERAGE PERCENTAGE <br />49,615 SF / 181,789 SF = 27.3% <br />M-M ZONE STANDARDS <br />(TABLE 6.1, DEVELOPMENT <br />STANDARDS) <br />SETBACKS: <br />FRONT: 20' <br />REAR: 20' <br />SIDE, STREET: 15' <br />SIDE, INTERIOR: 10' <br />MAX LOT COVERAGE BY <br />BLDG: N/A <br />MAX BLDG HEIGHT: 65' <br />n — — ­1 r <br />OFF-STREET LOADING REQUIREMENTS <br />(19.34.090, TABLE 34-2) <br />201000 - 50,000SF = 2 BERTHS <br />GROSS FLOOR AREA: 49,931 SF <br />2 LOADING DOCK BERTHS PROVIDED, <br />COMPLIES <br />LANDSCAPING AND SCREENING REQ. <br />(CHAPTER 19.35) <br />LANDSCAPE CATEGORY: D <br />LANDSCAPE TYPE: III <br />STREET FRONTAGE WIDTH OF <br />LANDSCAPING: 20 FT OR DISTANCE <br />BETWEEN BLDG AND LOT LINE <br />PARKING TO LANDSCAPE RATIO <br />(CHAPTER 19.35.080) <br />20SF OF LANDSCAPING PER PARKING STALL <br />96 STALLS X 20SF = 17920SF OF <br />LANDSCAPING REQ. <br />LANDSCAPING PROVIDED = 45,535 SF <br />PARKING CALCULATIONS: <br />(19.34.020 REQUIRED OFF-STREET PARKING) <br />TABLE NO. 34-1, BUSINESS PARK <br />1 PER 1,000 SQUARE FEET OF WAREHOUSE <br />AREA <br />1 PER 600 SQUARE FEET OF ASSEMBLY OR <br />LIGHT MANUFACTURING AREA. <br />'vz <br />PARKING REQUIREMENTS: UNLIMITED AREA BUILDINGS - IBC 507.5 <br />EXISTING BLDG (ASSEMBLY): SPRINKLERED, TWO-STORY BUILDING <br />28,381 SF / 600 = 48 STALLS OF GROUP B, F AND S NO MORE THAN <br />TWO STORIES ABOVE GRADE SHALL <br />NEW STORAGE BLDG (STORAGE): NOT BE LIMITED WHERE THE BUILDING <br />217073 SF / 1000 = 22 STALLS IS EQUIPED THROUGHOUT WITH AN <br />AUTOMATIC SPRINKLER SYSTEM IN <br />TOTAL PARKING STALLS REQUIRED '\ ACCORDANCE WITH SECTION 903.3.1.1 <br />= 70 AND IS SURROUNDED AND ADJOINED <br />ADA STALLS REQUIRED (PER IBC, BY PUBLIC WAYS OR YARDS NOT LESS <br />TABLE 1106.1) = 3 THAN 60 FEE IN WIDTH. <br />TOTAL PARKING STALLS PROVIDED ,,._ <br />= 80 STANDARD, 3 ADA <br />FISHER <br />CONSTRUCTION <br />GROUP <br />625 Fisher Lane <br />Burlington, WA 98233 <br />T: 360.757.4094 <br />F: 360.757.4005 <br />www.fishercgi.com <br />REV <br />DATE <br />REV 0 <br />2017-09-25 <br />REV 1 <br />2017-10-25 <br />sal` <br />1 � • <br />EXPANSION <br />2201 100TH ST. SW <br />Stamp: <br />' <br />uj <br />��E <br />�z <br />W <br />a° <br />U_ <br />a� <br />Drawing Title <br />ARCHITECTURAL <br />SITE PLAN <br />JOB #: 17FO35 <br />Drawing No: <br />Alel <br />SITE PLAN 1 <br />ill <br />= 20-4®° AIO A1.1 <br />PERMIT SET <br />