My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6930 CARSON RD 2021 Plans 2022-11-14
>
Address Records
>
CARSON RD
>
6930
>
Plans
>
6930 CARSON RD 2021 Plans 2022-11-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2022 9:47:44 AM
Creation date
4/21/2022 4:02:42 PM
Metadata
Fields
Template:
Address Document
Street Name
CARSON RD
Street Number
6930
Permit
B2102-037
Year
2021
Notes
BATHROOM / OFFICE ADDITIONS PLUS COVERED PORCH
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
nn ou iwo <br /> Instructions:This multifamily project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed. Based on the size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> Authorized Representative LarryThibeault Digitally signed by Laity Thibeault Date 05/14/2021 <br /> /� Date:lgro5.ib 06:5 oT -0T00' <br /> All Climate Zones(Table R402.1.1) <br /> R-Value a U-Factor a <br /> Fenestration U-Factor b n/a 0.30 <br /> Skylight U-Factor b n/a 0.50 <br /> Glazed Fenestration SHGC b,e n/a n/a <br /> Ceiling e 49 0.026 <br /> Wood Frame Wall g,h 21 int 0.056 <br /> Floor 30 0.029 <br /> Below Grade Wall c•h 10/15/21 int+TB 0.042 <br /> Slab d•f R-Value&Depth 10,2 ft n/a <br /> R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less <br /> a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table <br /> A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights. <br /> "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on <br /> the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br /> c the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on the <br /> interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."5TB"means R- <br /> 5 thermal break between floor slab and basement wall. <br /> d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> e For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth extends <br /> over the top plate of the exterior wall. <br /> R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f slab insulation when applied to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall meet <br /> the requirements for thermal barriers protecting foam plastics. <br /> For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for <br /> g climate zone 5 of ICC 400. <br /> Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. <br /> Prescriptive Path—Multifamily 2018 Washington State Energy Code-R 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.