GENERAL NOTES <br />THESE NOTES APPLY UNLESS NOTED OTHERWISE ON DRAWINGS <br />FIRE BLOCKING: <br />DESIGNER <br />THESE DRAWINGS ARE THE PROPERTY OF THE DESIGNER AND MAY ONLY BE REPRODUCED <br />FIRE -BLOCKING SHALL BE PROVIDED IN WOOD -FRAME CONSTRUCTION IN THE FOLLOWING <br />NAI/60RNY DE516N ING. DAN SAY <br />WITH THE WRITTEN PERMISSION OF THE DESIGNER. AUTHORIZED REPRODUCTIONS MUST <br />LOCATIONS: IN CONCEALED SPACES OF STUD MALLS AND PARTITIONS, AT SOFFITS AND COVE <br />ALEXAND CORNY 2124 AVE 100 <br />SEE �� ® GA <br />BEAR THE NAME OF THE DESIGNER. COPYRIGHT 2022 BY WAI / GORNY Inc. THESE <br />CEILINGS, IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF <br />SPOT ELEVATIONS DERIVE <br />DRAWINGS ARE FULLY PROTECTED BY FEDERAL AND STATE COPYRIGHT LAWS. ANY <br />THE RUN, AT OPENINGS AROUND VENTS, PIPES AND DUCTS. (IRC SECTION R302.11). <br />25504 FOUNTAIN DRIVE 5EATTLE NA q 121 <br />INFRINGEMENT OF THESE LAWS WILL BE PROSECUTED. ALL CONSTRUCTION SHALL CONFORM <br />SEE SECTION R1001.12 OF THE IRC FOR FIREBLOCKING OF CHIMNEYS AND FIREPLACES. <br />ARLIN&TON, IAA g&2g2 206 g56 5162 <br />TO THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC), AND BE IN ACCORDANCE WITH <br />560 62g 050q <br />THE WASHINGTON STATE LAWS AND REGULATIONS <br />ENERGY: <br />1�0RNY.G0�1 <br />ELEVATION <br />SOILS: <br />LR WORKMANSHIP AND CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION <br />D <br />Ag�.I <br />OFTHE-MATERIAL, <br />INTERNATIONAL BUILDING CODE AND THE WASHINGTON STATE ENERGY CODE. VERIFY <br />� � <br />�_�` <br />UNLESS A SOILS REPORT IS PROVIDED BY A SOILS ENGINEER AND ATTACHED TO THESE <br />ALL CONDITIONS BEFORE PROCEEDING WITH WORK. APPLICATION AND INSTALLATION OF <br />DOCUMENTS, THIS OFFICE ASSUMES NO RESPONSIBILITY FOR THE PHYSICAL CHARACTERISTICS <br />INSULATION AND VAPOR BARRIERS SHALL COMPLY WITH THE STATE OF WASHINGTON THERMAL <br />A1 ®����- NOTES, ����� INPO, SITE PLAN <br />G=g.7 <br />OF THE SOIL. FOUNDATION DESIGN IS BASED ON AN ASSUMED AVERAGE SOIL BEARING <br />INSULATION STANDARDS . MALLS SHALL BE INSULATED WITH R-21 BATT (FOR 2 X C <br />A2.0 OENER L STRUGTLR L DOTES <br />®=qb.4 <br />CAPACITY OF 2,000 PSF. FOOTINGS SHALL BE CAST ON UNDISTURBED, FIRM, NATURAL SOIL <br />WALLS) AND R-15 BATT (FOR 2 X 4 WALLS), UNLESS OTHERWISE NOTED. THE ROOF AND CEILING <br />A2•1 5TRUCTURAL PLANS <br />3g3.7 4 = q AVER <br />OR COMPACTED SOIL OF 2,000 PSF BEARING CAPACITY AT LEAST 1'-6" BELOW THE LOWEST <br />SHALL BE INSULATED WITH R-49 BLOWN OR R--38 ADVANCED FLAMING, SINGLE RAFTER VAULTEI <br />AZ STRUGTURAL DETAILS <br />.425 <br />ADJACENT GRADE, FREE OF ORGANIC MATERIALS. FOOTING EXCAVATION SHALL BE FREE OF <br />SHALL BE INSULATED WITH R-36 C BATT (U.N.O.). WHERE POSSIBLE, PROVIDE INSULATION IN THE <br />All MAIN FLOOR PLAN!, HINPON AND DOOR SGHEDUL-ES <br />DEBRIS, LOOSE SOILS AND FREE WATER AT ALL TIMES. THIS OFFICE ASSUMES NO <br />CEILING AND IN THE 2 X 12 RAFTERS IF A VAULTED CEILING CONDITION EXISTS. MAINTAIN A <br />A BWLDINO ELEVATIONS <br />RESPO SIBILY FOR VERIFYING THE ACCURACY OF ENGINEERING DATA SUPPLIED BY OTHERS. <br />MINIMUM OF 1" CLEARANCE BETWEEN THE TOP OF THE INSULATION AND THE BOTTOM OF THE <br />.0 <br />CONTRACTOR'S RESPONSIBILITY: <br />SHEATHING FOR VENTING. VENTING MUST OCCUR IN EACH JOIST SPACE. WHERE CONTINUOUS <br />A5.O BWLDINO SECTIONS, ENERO'- INFO <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND STRUCTURAL MEMBER SIZES PRIOR TO <br />VENTING WITHIN A JOIST SPACE IS INTERRUPTED BY A HEADER (LE., FOR A SKYLIGHT OR AT HIP <br />END), PROVIDE (2) 1 1/2 VENTING HOLES AT THE TOP OF THE RAFTER AT THE HEADER TO <br />CONSTRUCTION. THE CONTRACTOR SHALL INFORM THE DESIGNER AND STRUCTURAL ENGINEER <br />OF ANY DISCREPANCIES IN THE DRAWINGS OR WITH THE CODES. <br />ALLOW FOR CONTINUAL THROUGH -VENTING INTO THE NEXT JOIST SPACE. FLOORS SHALL BE <br />CHANGES INITIATED BY THE CONTRACTOR SHALL BE SUBMITTED 1N WRITING TO THE DESIGNER <br />INSULATED WITH R-30 BATT OVER UNHEATED SPADE (U.N.O<). ANY SLAB ON GRADE SHALL BE <br />.AND STRUCTURAL ENGINEER PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES INDICATED <br />.INSULATED WITH EXTRUDED RIGID CLOSED CELL INSULATION R-10. .INSULATION TO PROVIDE <br />SOLELY ON THE DRAWINGS WILL N0� SATISFY THIS REQUIREMENT; <br />THERMAL BREAK BETWEEN SLAB AND FOOTING AND RUN FROM THE TOP OF THE SLAB TO THE <br />PROJECTADDRESS <br />BOTTOM OF THE FOOTING. INSULATION MAY BE INTERRUPTED FOR 6" EVERY 2'-0" TO ALLOW <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE METHODS, TECHNIQUES, SEQUENCES OR <br />FOR DOWELING TO TIE THE SLAB AND FOOTING TOGETHER. AN APPROVED VAPOR BARRIER <br />2006 O KES AVENUE SE <br />PROCEDURES REQUIRED TO PERFORM HER OR HIS WORK, AS WELL AS BEING RESPONSIBLE <br />SHALL BE INSTALLED AT EXTERIOR WALLS AND AT ALL ROOF DECKS, BELOW ENCLOSED JOIST <br />EVE TT, NA g&20I <br />FOR ALL REQUIRED SAFETY PRECAUTIONS. STRUCTURAL SYSTEMS WHICH ARE COMPOSED OF <br />SPACES WHERE CEILING FINISHES ARE DIRECTLY INSTALLED TO JOISTS, AND ANY OTHER WALLASSESSOR'S <br />COMPONENTS TO BE ERECTED IN THE FIELD, SHALL BE ACCOMPANIED BY SUPPLIER <br />OR CEILING SURFACES WHICH RECEIVE INSULATION. THIS VAPOR BARRIER MAY BE A <br />0043-7g42 02g00 <br />SUPERVISION DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION <br />COMPONENT OF THE INSULATION MATERIAL. <br />ACCORDING TO THE INSTRUCTIONS PREPARED BY THE SUPPLIER. <br />LEGALDESCRIPTION <br />CRAWL SPACES: <br />LOTS 2q 30, E3LOGK 42, PLAT OF EVERETT, DIVISION K, AGGORDW7 TO <br />UNDER FLOOR AREAS SHALL BE PROVIDED WITH VENTILATION OPENINGS THROUGH FOUNDATION <br />THE PLAT THEREOF RECORDED IN VOLUME 5 OF PLATS, PAH 5, RECORDS <br />WALLS OR EXTERIOR WALLS. THE MINIMUM NET ARE OF VENTILATION OPENINGS SHALL NOT <br />NOT BE LESS THAN 1 S.F. FOR EACH 150 S.F. OF UNDER -FLOOR SPACE AREA. ONE SUCH <br />OF SNOHOMISH GOUNTY, KA5067TON. <br />VENTILATION OPENING SHALL BE "WITHIN 3 FOOT OF EACH CORNER OF SAID BUILDING. <br />(IRC SECTION R408.1) <br />ZONING CLASSIFICATION <br />VENTILATION OPENINGS SHALL BE COVERED FOR THEIR HEIGHT AND WIDTH WITH ANY OF THE <br />R-2 <br />MATERIALS SPECIFIED IN IRC SECTION R408.2, THE LEAST DIMENSION OF WHICH MAY NOT <br />EXCEED 1 /4 INCH (IRC SECTION R408.2) <br />GRADING INFO <br />ACCORDING TO IRC SECTION R406.4, ACCESS SHALL BE PROVIDED TO ALL UNDER -FLOOR <br />SPACES. ACCESS OPENINGS THROUGH THE FLOOR SHALL BE A MINIMUM OF 18 INCHES BY 24 <br />NONE PROPOSED , NO EXTERIOR NORK <br />INCHES. OPENINGS THROUGH A PERIMETER WALL SHALL BE 16 INCHES BY 24 INCHES, THE <br />AREAWAY SHALL BE BELOW THE THRESHOLD OF THE ACCESS OPENING. THROUGH <br />SITE DISTURBANCE <br />WALL ACCESS OPENINGS SHALL NOT BE LOCATED UNDER A DOOR TO THE RESIDENCE. <br />SITE DI5TUPBANGE LIMITED TO VERURGAlON OF EXISTING FOOTIN 5 <br />ATTIC: <br />ACCORDING TO IRC SECTION R607, IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF <br />MAXIMUM <br />CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED TO ATTIC AREAS THAT <br />EXCEED 30 SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR GREATER. THE <br />SEE HE6HT CALCULATIONS THIS SHEET AND SHEET A4.0 <br />ROUGH -FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES BY 30 INCHES AND SHALL BE <br />LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. A 30-INCH MINIMUM <br />UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME POINT ABOVE <br />VENTILATION: <br />WHERE TOILET ROOMS AND BATHROOMS ARE MECHANICALLY VENTILATED, THE EXHAUSE AIR <br />SHALL NOT BE RECIRULATED WITHIN A RESIDENCE, THE VENTILATION SYSTEMS SHALL BE <br />DESIGNED TO HAVE THE MINIMUM EXHAUST AIR FLOW OF 100 CFM INTERMITTENT OR 25 CFM <br />CONTINUOUS IN KITCHENS. IN BATHROOMS AN EXHAUST CAPACITY OF 50 CFM INTERMITTENT <br />OR 20 CFM CONTINUOUS IS REQUIRED. (IRC SECTION M1507.4) <br />RANGES/OVENS, AND CLOTHES DRYERS SHALL VENT INDEPENDENTLY AND DIRECTLY TO THE <br />OUTSIDE (IRC SECTION M1503.1 AND 1502.1). BROILER UNITS SHALL BE PROVIDED WITH AND <br />EXHAUST HOOD. (IRC SECTION M1505.1). <br />GLAZING: <br />GLAZING SHALL BE IN COMPLIANCE WITH THE IRC SECTION R30E AND THE WASHINGTON STATE <br />SAFETY GLASS LAW. EXCEPTIONS ARE AS OUTLINED IN IRC SECTION R306. BUILDING AREA <br />IN HAZARDOUS LOCATIONS AS SET FORTH BY THE IRC SECTION 308.4, GLAZING SHALL BE TYPE V6 R-3 5F 1-5TORY <br />PROVIDED WITH A MANUFACTUER'S LABEL DESIGNATING THE TYPE AND THICKNESS OF GLASS EXISTING <br />AND SAFETY GLASS STANDARD WITH WHICH IT COMPLIES, VISIBLE UPON THE FINAL INSTAL- UPPE FLOOR ADD TFON <br />LATION. THOSE HAZARDOUS LOCATION INCLUDE, BUT ARE NOT LIMITED TO: GLAZING IN TOTAL <br />LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS ON DOORS WITHIN A 24" ARC OF THE DOOR <br />IN A CLOSED POSITION AND WHOSE BOTTOM IS LESS THAN 60" ABOVE THE FLOOR, GLAZING IN EXIST AREA TO BE RENOVATED <br />DOORS AND ENCLOSURES FOR BATHTUBS AND SHOWERS, GLAZING ADHACENT TO STAIRWAYS, <br />LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE GLASS <br />IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE WALKING SURFACE SKYLIGHTS AND <br />HOUSE <br />6ARA6E <br />COVERED <br />PORCH <br />TOTAL <br />1,120.0 S.F. <br />215.0 5.F. <br />156 5.F. <br />2,151.0 5.F. <br />110.0 S.F. <br />0.0 5.F. <br />0.0 5.F. <br />10.0 S.F. <br />I,bgO.O S.F. <br />215.0 5.F. <br />156 S.F. <br />2321.0 S.F. <br />+ 310 S.F. <br />0.0 S.F. <br />0.0 S.F. <br />310 S.F. <br />SLOPED GLAZING OF MORE THAN 15 DEGREES SHALL HAVE LAMINATED GLASS WITH AN <br />INTERLAYER AS DESCRIBED IN IRC SECTION R308.6.2. <br />ALL EXTERIOR WALL GLAZING SHALL BE DOUBLE GLAZED AND COMPLY WITH STATE OF <br />WASHINGTON ENERGY CODE. <br />EMERGENCY ESCAPE: <br />BASEMENTS WITH HABITABLE SPACE, AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE <br />OPENABLE EMERGENCY ESCAPE. EMERGENCY EGRESS SHALL BE REQUIRED IN EACH SLEEPING <br />ROOM, BUT NOT IN ADJOINING AREAS OF THE BASEMENT. THE OPENING SHALL HAVE A SILL <br />HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR. WHERE A BULKHEAD IS REQUIRED, <br />IT SHALL PROVIDE DIRECT ACCESS TO THE BASEMENT WITH A MINIMUM CLEAR AREA OF 5.7 <br />SQUARE FEET. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM CLEAR <br />OPENING OF 5.7 SQUARE FEET, WITH THE EXCEPTION OF GRADE FLOOR OPENINGS, WHICH SHALL <br />HAVE A MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET. THE MINIMUM CLEAR OPENING <br />HEIGHT SHALL BE 24 INCHES. THE MINIMUM CLEAR OPENING WIDTH SHALL BE 20 INCHES. ALL <br />OPENINGS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEYS. THE MINIMUM <br />HORIZONTAL AREA OF A WINDOW WELL SHALL BE 9 SQUARE FEET, WITH A MINIMUM HORIZONTAL, <br />PROJECTION AND WIDTH OF 35 INCHES. COVER WALLS AND SOFFITS OF USABLE SPACE UNDER <br />THE STAR WITH 1/2 INCH TYPE "X" GYPSUM WALLBOARD. (IRC SECTION R310) <br />EGRESS: <br />THE MINIMUM WIDTH OF A HALLWAY SHALL BE NOT LESS THAN 3 FEET. (IRC SECTION R311.6) <br />AT LEAST ONE EXIT DOOR IS REQUIRED PER DWELLING UNIT. THE EXIT DOOR SHALL PROVIDE <br />DIRECT ACCESS TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. THE EXIT <br />DOOR SHALL BE A SIDE -HINGED DOOR NOT LESS THAN 3 FEET IN WIDTH AND 6 FEET S INCHES <br />IN HEIGHT. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF THE DOOR, EXCEPT WHERE <br />THERE ARE TWO OR FEWER RISERS LOCATED ON THE EXTERIOR SIDE OF A DOOR OTHER THAN <br />THE EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. THE FLOOR <br />AT THE EXIT DOOR SHALL NOT BE MORE THAN 1.5 INCHES LOWER THAN THE TOP OF THE <br />THRESHOLD. (IRC SECTION R311.3) <br />STAIRS: <br />MINIMUM WIDTH 36 INCHES; MAXIMUM HANDRAIL PROJECTION 4.5 INCHES; MINIMUM CLEAR WIDTH <br />AT AND BELOW HANDRAIL 31.5 INCHES WHERE THERE IS ONE HANDRAIL AND 27 INCHES WHERE <br />THE HANDRAIL IS ON BOTH SIDES. MINIMUM HEADROOM 6 FEET S INCHES; MAXIMUM RISER <br />HEIGHT 7 3/4 INCHES; MINIMUM TREAD DEPTH 10 INCHES. THERE SHALL BE A LANDING AT <br />THE TOP AND BOTTOM OF EACH STAIRWAY: HANDRAILS PROVIDED ON AT LEAST ONE SIDE ON <br />STAIRS WITH FOUR OR MORE RISERS. MAXIMUM HANDRAIL HEIGHT 38 INCHES; MINNUM HANDRAIL <br />INCHES AND NOT GREATER THAN 2 INCHES. HEIGHT 34 INCHES. TYPE I HANDRAIL SHALL HAVE <br />A DIAMETER OF NOT LESS THAN 1 1/4 AND MAXIMUM 38" ABOVE STAIR NOSING. HANDRAIL TO <br />BE 1 1/2" CROSS SECTION AND 1 1/2". TYPE 11 HANDRAIL WITH PERIMETER GREATER THAN <br />6 1 /4" SHALL PROVIDE A GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. <br />SEE IRC SECTION R311.7.5.3 FOR FURTHER DIMENSIONAL INFORMATION. (IRC SECTION R311.7) <br />GARAGES: <br />THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS <br />THAN 1/2 INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE <br />ROOMS SHALL BE SEPARTATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN <br />5/8-INCH TYPE X GYPSUM BOARD. THE STRUCTURE SUPPORTING THE ASSEMBLY SHALL BE <br />PROTECTED BY 1/2 INCH GYPSUM BOARD. (IRC SECTION R302.6) <br />104 5.F. <br /><g-*G> S.F. <br />l S.F. <br />APPROVED <br />office of commumy, manning & Economic pmewment <br />PLANNING DEPARTMENT <br />Permit#: <br />B=2-028 <br />i <br />Site Address: <br />2006 OAKES AVE <br />Owner: <br />G®bl@STE�N ARAM & NYCA <br />Tenant: <br />[TenNamel <br />App. Date: <br />Proposed Use: <br />2/10/2022 <br />RESMEN7ALALTERA-ROWS <br />WAI znc. <br />Description: <br />1L7CSF ADDF�ON FOR BEDROOM & BATH. <br />25504 MOUNTAIN DR. <br />f <br />ARLINGTON, WA93223 <br />Date: <br />(360) 629 0509 PH <br />Reviewed By: <br />www.waigorny.com <br />Office Set <br />Job Site Set Fire/Plarring Set <br />EX67N6 <br />✓` I n' VP . 0 6 R 80 <br />1 <br />_.j <br />METER BE <br />METERNGHMARC <br />1� <br />APPRO\'!.O'' O, & IHE �iSSLIAN,('�E OF <br />PUBLIC FIRE <br />SUPPRESSION, I` LE- ! RICAL OR <br />PLUMBING P ERIVOTS <br />OAKE AVE SE <br />0 10 20 <br />uj <br />CD <br />< <br />0 <br />LLJ <br />Co C-4 <br />ca <br />Additions' <br />FotO 1"hi 4 +PI G on <br />PIurnbirtg �-pI°IVTK <br />7Y OF EVERETT <br />