Section <br />Township <br />Range <br />Quarter <br />STANDARDS: <br />Building Code <br />IRC 2018 Edition <br />Energy Code <br />WSEC 2018 Edition <br />Floor Loading <br />40psf LL / 12psf DL = 52psf <br />Deck(s) Loading <br />60psf ILL / 10psf DL = 70psf <br />Roof Loading <br />25psf LL/ 17psf DL = 42psf <br />Jurisdiction <br />City of Everett <br />Zoning <br />R-2 <br />LEGAL DESCRIPTION: <br />EVERETT DIV R PLAT OF <br />Plat Block: 243 D-00 <br />Plat Lot: 21-22 <br />SCOPE OF WORK: <br />residence. <br />rear 1. Construct new master suite addition on o r <br />F.A.R. CALC: <br />Lot Area: <br />Maximum F.A.R.: <br />Total G.F.A.: <br />Exemption Areas: <br />Chargeable Floor Area: <br />Chargeable = Lot Area <br />AVERAGE GRADE: <br />A = 142.00 <br />B = 142.13 <br />C = 141.04 <br />D = +140.47 <br />565.64=4=141.41 <br />--F7HS "N IS NOT ON 22x34 PAPER, IT HAS BEEN SCALED ACCORDINGLY---,, <br />LOT COVERAGE; <br />ONTACTS: <br />Proposed Addition: 374.00 ft2 <br />Main Residence. 792.00 .t2 <br />J V I L <br />Covered Porch: 60.00 ft2 <br />Detached Garage: + 480.00 ft2 <br />r e Owner: <br />ary & Ardis McLean <br />Structural <br />Sttural Design Associates, Inc <br />ddress; <br />�nn Rucker Avenue <br />Address: <br />3006 Rucker Avenue <br />verett, Washington 98201-1614 <br />Everett, Washington 98201 <br />ontact: <br />Gary McLean (425) 765-8578 <br />Contact: <br />Office (425) 339-0293 <br />Total. 1,806.00 ft2 <br />Lot Size. = 6,100.00 ft2 <br />rojectDesignec <br />NuttyCAD Drafting & Design, LLC <br />GEOTechnical Consultant(s): <br />T.B.D. <br />ddress: <br />�300 139th Avenue S.E. <br />Address: <br />- <br />Allowed: 40% Actual: <br />0o0u- 0- <br />nohomish, Washington 98290 <br />- <br />contact: <br />Douglas Almond (206) 225-0068 <br />Contact: <br />- <br />I m0^-t <br />A` <br />New Impervious. 466.00 ft2 '3 C, <br />TEB.Dsultant(s): <br />Existing Impervious: + 2,019.00 ft2 Address: Address: <br />Total: 2,485.00 ft2 - <br />Contact: Contact: <br />Lot size: 6,100.00 ft2 - - <br />Allowed: 65% Actual: 1. % <br />AREA OF WORK 120.00' <br />I THIS ERMIT, <br />" r 5-00'- S-13t _�-7 <br />35'-01, I 17-0" % 68'-0' I. <br />II Z ------------------- L--------- °' <br />-- - ------ -- ---- - w - w w -w -w w w <br />I i / N EXISTING CONCRETE WALK N <br />S S s-+- S 5A S S 5 4-t� , �� A , �. <br />o EXIST DWELLING ` <br />o EXIST GARAGE <br />O y� <br />I N I N i u CO <br />CD I I r ��0 <br />C.0 ` io <br />W I �--------------1- <br />" J EXIST o ( Z <br />J I - l\ N <br />IL - - - - -- -- -- t - I - --- J_ <br />Ip4 " <br />-- - - 'O DECD <br />------ - ----- -- --(--------� <br />" Zo <br />�._._.-._.-._._....... _.�\-. 5.00'BSBL 1--._._- <br />--------- <br />_._._._1 <br />" I <br />I <br />1 20.00' <br />-- 104 <br />3 <br />- w W <br />CL <br />d <br />V <br />O <br />CD <br />Z m <br />Z <br />Z <br />N3 <br />w <br />W <br />3 <br />I <br />VICINITY MAP: Scale:1"=200' ENERGY CODE COMPLIANCE: <br />Each dwelling unit in a residential building shall comply with sufficient options from Table R4062 (fuel <br />0 normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of <br />credits. To claim this credit, the building permit drawings shall specify the option selected and the maximurr <br />tested building air leakage, and show the qualifying ventilation system and its control sequence of <br />operation. <br />1. Small Dwelling Unit: 3 credits <br />Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. <br />Additions to existing building that area greater than 500 sf of heated floor area but less than 1,500 sf. <br />2. Medium Dwelling Unit: 6 credits <br />All dwelling units that are not included in #1 or #3 <br />3. Large Dwelling Unit: 7 credits <br />Dwelling units exceeding 5,000 sf of conditioned floor area <br />4. Additions less than 500 square feet: 1.5 credits <br />All other additions shall meet 1-3 above <br />7 <br />Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. <br />Summary of Table R406.2 <br />Heating Credits - Select ONE <br />Fuel Normalization Descriptions User Notes: <br />0Options heating option <br />W' "' `' 1 Combustion heating minimum NAECA b 0.0 ❑ <br />2 Heat pump ° 1.0 ❑ <br />3 Electric resistance heat only - furnace or zonal -1.0 ❑ <br />4 DHP with zonal electric resistance per option 3.4 0.5 ❑ <br />5 All other heating systems -1.0 ❑ <br />fl <br />Know what'sbelow. <br />Call before you dig. <br />D <br />W <br />Q <br />Lit <br />D APPROVEDI <br />'. ice of Commt,nity, Planning & Economic Development <br />PLANNING DEPARTMENT <br />44AME: (/ DATE: Gam` <br />?FCtUIRED <br />r,a <br />1 ° { try"' ay.� <br />- <br />6 OO s w h '.d . i' x'a i' 1 1 l� G 3) <br />APPROVED <br />PUBLIC WORKS DEPAR ENS <br />BY <br />DATE <br />CITY OF EVERETT REVIEWED FOR PERMIT <br />PLAN <br />NORTH <br />Energy <br />aptions <br />Energy Credit Option Descriptions <br />Credits - Select ONE <br />energy option from each <br />category <br />User Notes: <br />1.1 <br />Efficient Building Envelope <br />0.5 ❑ <br />1.2 <br />Efficient Building Envelope <br />1.0 ❑ <br />1.3 <br />Efficient Building Envelope <br />0.5 ❑ <br />1.4 <br />Efficient Building Envelope <br />1.0 ❑ <br />1.5 <br />Efficient Building Envelope <br />2.0 ❑ <br />1.6 <br />Efficient Building Envelope <br />3.0 ❑ <br />1.7 <br />Efficient Building Envelope <br />0.5 ❑ <br />2.1 <br />Air Leakage Control and Efficient Ventilation <br />0.5 13 <br />2.2 <br />Air Leakage Control and Efficient Ventilation <br />1.0 <br />2.3 <br />Air Leakage Control and Efficient Ventilation <br />1.5 ❑ <br />2.4 <br />Air Leakage Control and Efficient Ventilation <br />2.0 ❑ <br />3.1a <br />High Efficiency HVAC <br />1.0 ❑ <br />3.2 <br />High Efficiency HVAC <br />1.0 ❑ <br />3.3a <br />High Efficiency HVAC <br />1.5 ❑ <br />3.4 <br />High Efficiency HVAC <br />1.5 ■ <br />Mini -split HSPF 10 <br />3.5 <br />High Efficiency HVAC <br />1.5 ❑ <br />3.6a <br />High Efficiency HVAC <br />2.0 ❑ <br />4.1 <br />High Efficiency HVAC Distribution System <br />0.5 ❑ <br />4.2 <br />High Efficiency HVAC Distribution System <br />1.0 ❑ <br />5.11 <br />Efficient Water Heating <br />0.5 ❑ <br />5.2 <br />Efficient Water Heating <br />0.5 ❑ <br />5.3 <br />Efficient Water Heating <br />1.0 ❑ <br />5.4 <br />Efficient Water Heating <br />1.5 ■ <br />Heatpump WH <br />5.5 <br />Efficient Water Heating <br />2.0 ❑ <br />5.6 <br />Efficient Water Heating <br />2.5 ❑ <br />6.1e <br />Renewable Electric Energy (3 credits max) <br />1.0 ❑ <br />7.1 <br />Appliance Package <br />0.5 ❑ <br />Total Credits <br />1.5 <br />a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or <br />500 W, whichever is bigger, may be installed in the dwelling unit. <br />b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) <br />c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) <br />d. You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may <br />be combined with options 5.2 through 5.6. See Table 406.3. <br />e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. <br />See the complete Table R406.2 for all requirements and option descriptions. <br />OPTION 3.4 <br />Ductless mini -split heat pump system, zonal control: In homes where the primary space heating system is <br />zonal electric heating, a ductless mini -split heat pump system with a minimum HSPF of 10.0 shall be <br />installed and provide heating to the largest zone of the housing unit. <br />OPTION 5.4 1 <br />Water heating system shall include one of the following: <br />Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating <br />specification <br />OR <br />For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier I of NEEA's <br />advanced water heating specification, shall supply domestic hot water to all units. If one water heater is <br />serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with <br />R-8 minimum pipe insulation. <br />THESE DOCUMENTS HAVE <br />NOT BEEN APPROVED FOR THE <br />ISSUANCE OF PUBLIC WORKS, <br />MECHANICAL, FIRE SUPPRESSION, <br />ELECTRICAL OR PLUMBING PERMITS. <br />Additional <br />For This Project <br />plumbing 0 Sprinkler <br />Mechanical 0 Fire Alarm <br />i <br />Z <br />Electrical <br />Roof trusses to be designed <br />and drawing prepared by <br />a State licensed structural <br />engineer. <br />CITY OF EVERETT <br />` IE ED FOR PERMIT <br />Permit#: <br />B2107-065 <br />U <br />Site Address <br />Owner: <br />1322 BUCKER AVE <br />MCLEAN GARY S & ARDIS M <br />Tenant: <br />[TenName] <br />App. Date: <br />7/26/2021 <br />PLANS EXAMIND APPR 6 IULL <br />Proposed Use: <br />RESIDENTIAL ALTERATIONS <br />Description: <br />ADDITION OF A MASTER SUITE BEDROOM <br />CITY OF EVERETT' <br />AND BATHROOM <br />Permit Services <br />��:�'�l 091Z012- <br />Reviewed By: <br />Date: <br />X Office Set <br />Jcb Site Set Fire/Planning Set <br />Va <br />Z0a <br />a <br />0 <br />N <br />_ <br />N <br />W v <br />} Q <br />eQD <br />Z% <br />c .o <br />0 <br />sg <br />C <br />L <br />o <br />N <br />S2 a <br />m <br />W � <br />� <br />, <br />oy <br />Q=0o <br />�wN <br />� <br />z <br />E <br />v V� <br />w'a[i <br />,,rmit Service'�l <br />`S <br />u <br />0 <br />V <br />-, <br />C <br />43 <br />� <br />o <br />N <br />C <br />> O <br />+� <br />G <br />au <br />V <br />= 3: <br />N <br />O <br />M <br />�> <br />a <br />W <br />O <br />N <br />t!t <br />00 <br />ci <br />Plan Titte <br />Site Plan <br />Douglas Almond <br />flat <br />07/13/2021 <br />21-043-01 <br />Plan Revisions <br />08/11/2021 <br />O - <br />0 - <br />O - <br />O - <br />Street: <br />1 FLOOR PLAN SCALE:1"=1'-0" of - <br />