5LADING CODE <br />2015 INTERNATIONAL BUILDING CODE <br />ff LOOR LOAD <br />DEAD LOAD : 12 ;p5f <br />LIVE LOAD: 40 p5f <br />ROOF LOAD <br />DEAD LOAD: 15 p5f <br />FLAT ROOF SNOW LOAD: 25 p5f <br />SNOW EXPOSURE FACTOR (Ce). 1. 1 <br />SNOW LOAD IMPORTANCE FACTOR (15): I .0 <br />THERMAL FACTOR (Ct): I . I <br />WINE) Dff5i N .DATA <br />I . BA51C WIND SPEED: 110 MPH <br />2. WIND IMPORTANCE FACTOR (Iw): I .O <br />BUILDING CATEGORY: II <br />3. WIND EXPOSURE: B <br />. Kzt = 1.35 <br />5. INTERNAL PRESSURE COEFFICIENT: NA <br />G. APPLICABLE WIND PRESSURE FOR <br />COMPONENTS AND CLADDING: NA <br />SESIMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: I .0 <br />SEISMIC USE GROUP: I <br />2. SPECTRAL RESPONSE ACCELERATION (55). 1 22.3% G <br />3. 51TE CLASS. D (ASSUMED) <br />fir. SPECTRAL RESPONSE COEFFICIENTS (SOS): 82.3 <br />5. SEISMIC ES1GN ATEGOR.Y: 0 <br />G. BASIC 5EI5MIC-FORCE-RE515TING SYSTEM: SHEARWALL5 <br />7. DESIGN BASE SHEAR: SEE CALCULATIONS <br />B. SEISMIC RESPONSE COEFFICIENT (C).. 127 <br />S. RESPONSE MODIFICATION FACTOR (R)a G.5 <br />10. ANALY515 PROCEDURE USED: EQUIVALENT LATERAL <br />FORCE PROCEDURE <br />FRAMINGLUM E <br />1. FRAMING LUMBER. SHALL BE HEM[ -FIR NO. 2. GRADES <br />ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS, <br />LUMBER TO BE GRADE MARKED PER WCLIB <br />SPECIFICATIONS. <br />2. STRUCTURAL SHEATHING SHALL BE APA RATED <br />PLYW000, EXPOSURE I SHEATHING CONFORMING TO <br />EITHER. HER. COMMERCIAL STANDARDS PSI -S3, APA PRP-108, <br />OR VOLUNTARY PRODUCT STANDARD PSE-132. PROVIDE A <br />MINIMUM OF 3/,5" IfDGE DISTANCE ON ALL NAILS AND Y,,,5' <br />EXP"AN51ON JOINT BETWEEN ALL PANEL EDGES. MINIMUM <br />SHEATHING REQUIREMENTS ARE AS FOLLOWS - <br />ROOF 5HEATHING TO BE e 5/32"B INT-APA RATED <br />PLYWOOD OR 7/r," 055 WITH EXTERIOR GLUE, P.I. <br />24/0, NAIL WITH 8d NAILS AT G°" ON CENTER AT <br />PANEL EDGES AND 1 2" ON CENTER AT INTERMEDIATE <br />IVii1EI 15ER5. <br />STUB FLOORING TO BE -%" TONGUE AND GROOVE C-0 <br />INT-APA RATED PLYWOOD OR 055 WITH EXTERIOR <br />GLUE, P.L 45/24. GLUE AND NAIL WITH I Ca NAIL5 <br />AT G" ON CENTER AT PANEL EDGES AND 12" ON <br />CENTER AT INTERMEDIATE MEMBEIR5. <br />3. NAILING 51HALL. CONFORM TO TABLE 2304a3. 1 OF TdEl <br />INTERNATIONAL BUILDING CODE UNLESS NOTED <br />OTHERWISEE. USE COMMON NAILS THROUGHOUT UNLE-55 <br />NOTED OTHERWISE. <br />4. NO STRUCTURAL MEMBER SMALL BE CUT OR NOTCHED <br />UNLESS 5FECIMCALLY DETAILED OR APPROVED IN WRITING <br />BY THE STRUCTURAL ENGINEER, <br />5. PROV. DE PROPERLY S12ED WASHERS UNDER HEADS AND <br />NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON <br />W00D. <br />G. PROVIDE 3"°x3"x0.225" W hER5 AT ALL ANCHOR <br />BOLTS <br />7a BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT <br />PLU5 XG" UNLESS NOTED OTHERWI5E, LAG BOLT PILOT <br />HOLES SHALL BE PRE -DRILLED TO GO% OF THE NOMINAL <br />DIAMETER OF THE LAG BOLT UNLE55 NOTED OTHERWISE. <br />B, ALL 51LL PLATES SHALL BE BOLTED TO THE FOUNDATION <br />WITH !/a" MINIMUM DIAMETER BOLTS SPACED AT A <br />MAXIMUM OF " ON CENTER. BOLTS MUST BE <br />EMBEDDED A MINIMUM OF 7" INTO CONCRETE OR <br />MA50NRY. 5EE FLANS AND DETAILS FOR 5Pff0 IC <br />REQUIREMENTS WHERE APPLICABLE, <br />. RIM J06T I5 TO BE 1 fq" L5L MINIMUM, <br />10. PROVIDE DOUBLE JO13T UNDER ALL PARALLEL <br />PARTITION WALLS AND SOLID BLOCKING UNDER <br />PERPENDICULAR PARTITION WALL5. <br />1 1. CONTACT THUS OFFICE PRIOR TO MAKING ANY <br />CHANGES TO TtiE5E DETAVL5. <br />OU N DATION <br />I . THE FOUNDATION DESIGN IS BASED ON Tl`iE RECOMMENDATION IN <br />THE INTERS NATIONAL BUILDING CODE TABLE 1804.2. FOUNDATION <br />WORK SHALL BE PERFORMED IN ACCORDANCE WITH CHAPTER. 16 OF <br />THIS CODE. <br />2, THE FOUNDATION !DESIGN IS BASED ON THE FOLLOWING VALUES. <br />ALLOW. SOIL BEARING 15 00 PSF <br />SOIL FRICTION .35 <br />EQUIV. FLUID PRESSURES <br />ACTIVE PRESSURE` 35 PCF <br />PASSIVE PRESSURE 250 PCF <br />3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 15°" BELOW THE <br />UNDISTURBED GROUND SURFACE OR TO FROST IDEPTI -i. ALL FOOTINGS <br />SMALL BE FOUNDED ON COMPACTED FILL OR UNDISTURBED NATURAL <br />GRADE UNLESS OTI IERM-9E NOTED. <br />4. COMPACTION: MATERIAL FOR FILLING AND BACK.FILLIING SHALL <br />CONSIST OF THE EXCAVATED MATERIAL AND/OR IMPORTED BORROW <br />AND SHALL BE FREE OF ORGANIC MATTER, TRASH, LUMBER, OR OTHER <br />DEBRIS. ALL WALLS SHALL BE ADEQUATELY BRACED PRIOR TO <br />BACKFILLING. FILL AND BACKFILL SHALL BE [DEPOSITED IN LAYERS NOT <br />TO EXCEED 5 INCHES THICK, PROPERLY MOISTENED TO APPROXIMATE <br />OPTIMUM REQUIREMENTS AND THOROUGHLY ROLLED OR COMPACTED <br />WITH APPROVED EQUIPMENT IN SUCH A MANNER. AND EXTENT AS TO <br />PRODUCE A RELATIVE COMPACTION OF 50% OF MAXIMUM POSSIBLE <br />DENSITY AS DETERMINED BY A5TM D 1557. LAND TAMPERS SHALL <br />WEIGH AT LEAST 50 POUNDS EACH AND SHALL HAVE A FACE AREA NOT <br />IN EXCESS OF G4 SQUARE INCHES.. LAND TAMPERS MAY BE OPERATE[) <br />EITHER MANUALLY OR MECHANICALLY AND SHALL BE USED WHERE <br />LARGER POWER. DRIVEN COMPACTION EQUIPMENT CANNOT BE USED. <br />STRUCTU L FILL OVER 12" DEEP SHALL COMPLY WITH A GEOTECHNICAL <br />REPORT. <br />CONCRETE <br />1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR <br />WEIGHT HARD ROCK TYPE (1 50 PCF) AGGREGATES SHALL CONFORM TO <br />A5TM C33 WITH PROVEN 5MRINKAGE CHARACTER15TIC5 OF LE55 T11AN <br />0.05%. <br />2. ALL CONCRETE DE51GN 15 BASED ON A 28 DAY COMPRESSIVE <br />STRENGTH (f"c) OF 2500 P51. MERE 3000 PSI CONCRETE 15 REQUIRED <br />BY THE BUILDING DEPARTMENT FOR WEATHERING PURPOSES ONLY, NO <br />SPECIAL INSPECTION 15 REQUIRED. <br />3. CEMENT SHALL CONFORM TO A5TM C 150, TYPE I, C5A NORMAL. <br />4. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. <br />5. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI <br />301. <br />G. CONCRETE SHALL BE MAINTAINED IN A M015T CONDITION FOR A <br />MINIMUM OF FIVE (5) DAYS AFTER PLACEMENT. ALTERNATE METHODS <br />WILL BE APPROVE[) IF 5AT15FAGTORY PERFORMANCE CAN BE ASSURED. <br />7. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL CASES. ALL <br />CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND ALL <br />LAITANCE SMALL BE RE -MOVED. ALL VERTICAL JOINTS SHALL BE <br />THOROUGHLY WETTED AND SLUSHED WITH A COAT OF NEAT CEMENT <br />IMMEDIATELY BEFORE PLACING NEW CONCRETE. <br />B. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT. (FOUR, <br />JOINTS SHALL BE LOCATED TO MINIMIZE EFFECTS OF SHRINKAGE AS <br />WELL AS PLACED AT POINTS OF LOW STRESS, MAXIMUM AREA OF POUR <br />JOINTS IS -400 5F. <br />5. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOP, <br />FORMED WORK SHALL BE A5 FOLLOWS: <br />INTERIOR WALL. 3/4" <br />!EXTERIOR WALLS, EXPOSE® TO WEATHER; 1 Vz" <br />EXP05ED TO EARTH OR WEATHER ( 5 OR SMALLER). I V2" <br />*NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3"° MIN. <br />COVERAGE <br />I Oo PIPE5 OTHER THAN ELECTRICAL COND6UI'75 SHALL NOT BE <br />EMBEDDED IN STRUCTURAL CONCRETE EXCEFT WHERE SPECIFICALLY <br />APPROVE[[). <br />1 1. CONCRETE MIXE5 SHALL BE PROVIDED IN ACCORDANCE WITH ACI <br />315 (WHEN STRENGTH DATA FROM TRIAL BATCHES OR F6ELRD <br />EXPERIENCE ARE NOT AVAILABLE). <br />CEMENT CONTENT 5ACK5 <br />PER <br />L55/CU5iC YARD CUBIC YARD <br />F"c (PSI) (MINIMUM) <br />(M6NIML9M) <br />2500 (no spcoal mspectuon) 470 5 <br />SEE NOTE A <br />3000 517 5 �1/2 <br />MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. <br />NO MORE THAN A I °" PLUS TOLERANCE SHALL BE ALLOWED. <br />A) WHERE SPECIAL IN51`ECTION IS NOT REQUIRED UNDER SECTION <br />1704.4 OF THE I.B.C., CONCRETE SHALL HAVE A MINIMUM CEMENT <br />CONTENT OF 5 5ACI\5 PER CUBIC YARD OF CONCRETE. <br />B) DESIGN MIX (OTHER. THAN AS SPECIFIED IN TMI5 TABLE) SHALL BE <br />5UBMlITTE€D TO THE BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST <br />USE. <br />INFO ONG STEEL <br />1, ALL REINFOR0NG STEEL SHALL CONFORM TO ASTM AG 15 GRADE GO (. = GAD <br />K.5I) FOR BAR 51ZES NO. 5 � LARGER, GRADE 40 (f i = 40 KSl) FOR NO, 3 AND <br />NO. 4 BARB. <br />2, ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE PLANS. WHERE <br />LAP OR SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED ON THE <br />CONSTRUCTION DOCUMENTS, LAPS AND/OR SPLICES SHALL BE 42 BAR DIA AND <br />BE WELL STAGGERED. <br />3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED IN ACCORDANCE <br />WITH ACI 315 SHALL BE REVIEWED BY THE ENGINEER AND AVAILABLE ON THE JOB <br />SITE PRIOR TO THE PLACING OF CONCRETE. <br />4. WELDED WIRE FABRIC SHALL CONFORM TO A -"--,TM A52 AND A 155 AND SHALL <br />BE GxG W2o IAV2. 1 UNLESS OTHERWISE NOTED. LAP REINFORCEMENT GG' <br />MINIMUM. <br />5. ANiCHOR, BOLTS, DOWELS AND OTHER, EMBEDDED ITEMS SMALL BE SECURELY <br />TIED IN PLACE BEFORE CONCRETE 15 POURED, SLAB ON GRADE REINFORCEMENT <br />SHALL BE PLACED AT MID -DEPTH OF SLAB AND SHALL BE HELD SECURELY IN <br />PLACE MTN I` ECHAMCAL !DEVICES DURING PLACING OF THE CONCRETE. <br />ROOF TRUSS <br />1. THE TRUSSES SHALL BE DESIGNED BY THE FABRICATOR TO FIT DIMENSIONS <br />AND LOADS INDICATE[) ON THE PLANS AND IN THE STRUCTURAL NOTES, ALL <br />DESIGNS SHALL BE IN ACCORDANCE WITH ALLOWABLE VALUES ASSIGNED BY THE <br />BUILDING CODE. CONCENTRATED MECHANICAL ROOF LOADS SHALL BE INCLUDED <br />IN THE DESIGN. VERIFY WEIGHTS AND LOCATIONS WITH THE ARCHITECT. 5MDP <br />DRAWING5 MUST BE RETAINED AT THE JOB SITE AND AVAILABLE TO THE BUILDING <br />INSPECTOR FOR REFERENCE, THE TRUSS CALCULATION PACKAGE SHALL BE <br />DE-51GNED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER <br />LICENSED IN THE STATE OF WASHINGTON. THE TRU55 ENGINEER SMALL ASSUME <br />ALL RESPONSIBILITY FOR THE WORK OF ALL SUBORDINATES INVOLVED IN THE <br />PREPARATION OF THE TRUSS PLACEMENT PLANS AND THE TRU55 DESIGN <br />DRAWINGS. <br />2. SHOP DRAWINGS AND CALCULATIONS SMALL BE SUBMITTED TO THE ENGINEER <br />FOR APPROVAL PRIOR TO FABRICATION[. DRAMNG5 AND CALCULATIONS SHALL <br />BE STAMPED AND SIGNED BY A REGISTERED PROFE5510NAL ENGINEER. THE <br />DRAWINGS SHALL SHOW ALL CRITICAL DIMENSIONS AS WELL AS THE LOADS THE <br />TRUSSES ARE !DESIGNED TO SUPPORT. THE TRUSSES ARE TO BE ERECTED AND <br />INSTALLED IN ACCORDANCE WITH THE PLANS, APPROVED FABRICATOR <br />DRAWINGS, AND IN5TALLATIONN SUGGESTIONS. CONTRACTOR SHALL GIVE <br />NOTIFICATION PRIOR TO ENCLOSING THE TRU55ES TO PROVIDE AN OPPORTUNITY <br />FOR, INSPECTION OF THE INSTALLATION. [DESIGN AND PROVIDE BRIDGING <br />BETWEEN TIME TRUSSES, CONTINUOUS LATERAL BRACING AND DIAGONAL <br />BRACING PER, TRU55 PLATE INSTITUTE RECOMMENDATIONS. SHOP DRAWINGS <br />MAY CONTAIN THE MANUFACTURER5 ENGINEERING RESPONSIBILITY LIMITATIONS. <br />HOWEVER, THEY SHALL MAKE NO STATEMENT AS TO THE ENGINEER OF RECORD <br />RE5PON5IDILITIE5. <br />GLUED -LAMINATED TIMBER <br />1. ADHESIVE SHALL BE POP, WET USE. <br />BEAM PER FLAK <br />(COST PER PLAN <br />GENERAL <br />u" . ALL MATERIJNL5 AND WORKMAN5hG? 5HA.LL CONFORM TO ThE CONTRACT <br />DRAW! NGS o <br />2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR 511ALL BE <br />RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE CONTRACTOR 511AL L <br />PROVIDE ADEQUATE SHORING, BRACING AND GUYS IN ACCORDANCE WITH ALL <br />NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. ANY DEVIATION MUST BE <br />APPROVED PRIOR. TO ERECTION. <br />3� ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA 5TANDARID3, ANY <br />DEVIATION MUST BE APPROVED BY OSHA PRIOR TO ERECTION. <br />4. THE CONTRACTOR, SHALL BE SOLELY RESPONSIBLE FOR ALL CONS[ -RUCTION <br />PROCEDURES INCLUDING LAGGING, -SHORING AND PROTECTION OF ADJACENT <br />PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL <br />NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. <br />5, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF <br />ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SMALL BE <br />CALLED TO THE ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE <br />PROCEEDING WITH THE WORD.. <br />G. SHOP DRAWINGS FOR PREFABRICATED TRUSSES AND MANUFACTURED FLOOR <br />JOISTS SMALL BE SU5M9TTEID TO THE ENGINEER FOR REVIEW PRIOR TO <br />FABRICATION. <br />7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. <br />WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR <br />CHARACTER TO DETAILS SHOWN, 51MILAP DETAILS OF CONSTRUCTION SHALL BE <br />USED SUBJECT TO REVIEW BY THE ENGINEER. <br />. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN <br />ADDITION TO ANY OTHER 5PE0FIC DETAIL CALLED OUT. <br />. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR <br />SIZE AND LOCATION OF ALL OPENINGS REQUIRED FOR (DUCTS, PIPES, PIPE <br />SLEEVES, ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN <br />CONCRETE OR OTHERWISE INCORPORATED IN 5TRUCTURAL WORF,. <br />10. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD [DETAILS <br />FOR HEATERS, MECHANICAL EQUIPMENT, VENT5, DUCTS, PIPING, ETC, ALL <br />5U5PENDEO MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED, <br />1 1. ARCHITECTURAL AND MECHANICAL PLANS ARE CON51DER.ELD A PART OF THE <br />STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE [DETAIL <br />CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF <br />MEMBERS, ELEVATIONS, DIMENSIONS AND LOCATIONS OF ALL OPENINGS, ETC. <br />G)DOUSLE TOP PLATE W/ EDGE NAILING (DHOLDOWN PER SCHEDULE <br />(STAGGER) <br />AND PLAN (ND 3®SDS <br />GSHEARWALL EDGE NAILING AT ALL PANEL <br />SHE <br />EDGES. BLOCKING AT ALL PANEL EDGES <br />COORDONATE ALL STUD <br />WHERE APPUCA LE. <br />AND PLATE SIZES w <br />(DEDGE NAILING TO HOLDOWN POST (BULL <br />SHEARWALL SCHEDULE <br />HEIGHT) STAGGER INTO DOUBLE STUDS <br />REQUIREMENTS <br />STUDS 0 16" ON CENTER <br />EDGE NAIUNG TO POSTS, <br />PRESSURE TREATED SILL PLATE WITH <br />TRIM STUDS, AND LINO <br />EDGE NAILING AND ANCHOR BOLTS PER <br />STUDS <br />BEARING STUD FOR <br />SHEAR ALL SCHEDULE. <br />(E)TOP PLATE SPLICE NAILING TO BE () 1d <br />DEADER <br />SINKERS (MIN). LAP " 1 INIMUN& <br />CENTER SPLICE ON STUD. <br />�,STD. SHEARWALL ELEVATtION <br />W./O RIM------ <br />� 3£ <br />Lu <br />O <br />Lu <br />L <br />q <br />z <br />N' <br />JUL 15 2021 <br />