4715 W VIEW DR 2021 Plans 2022-11-01
>
Address Records
>
W VIEW DR
>
4715
>
Plans
>
4715 W VIEW DR 2021 Plans 2022-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2022 3:56:04 PM
Creation date
4/22/2022 8:24:15 AM
Metadata
Fields
Template:
Address Document
Street Name
W VIEW DR
Street Number
4715
Permit
B2102-016
Year
2021
Notes
ADD 396 SQ FT TO SFR FOR NEW BED AND BATHROOM, ADD 2 DORMERS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> At Permit#: B2102-016 j <br /> Site Address: 4715 W VIEW DR �, _�w n�I t <br /> rOwner: AESCHLEMAN VANCE E III&ALEAS L j x ARE T �"MCA D ELEC0 Tenant: [TenName] ;Ur.ER "'ROUND) REQUIRED <br /> App. Date: 1/29J2021 Pr c <br /> CITY OF EVERETT a:. NEC 250.50 General Notes <br /> Proposed Use: RESIDENTIAL ALTERATIONS REVIEWED FOR PERMIT ("\I PECTED AT 1 GENERAL NOTES: <br /> T ®�1yeW +3� 1A LF[ WORK IS <br /> TO COMPLY WITH <br /> Description: ADD 396 SQ FTTO SFR FOR NEW BED AND `� ��� RESIDENTIAL CODE AND ANY <br /> BATHROOM,ADD 2 DORMERS Cf�" APPLICABLE STATE,COUNTY OR <br /> )(- - --- -- _ --- lift l LOCAL REGULATIONS <br /> C . PPROV _n f 11( /" PROJECT DESCRIPTION 2. SITE PLAN: <br /> 2.1. PROPOSED REMODEL <br /> SITE ADDRESS PROPOSED HOME ADDITION INCLUDES <br /> P"AI'� isSINO c COMMUNITY 2.1.1. 18'X22'EXPANSIONTO <br /> L VANCE & ALEAS AESCHLEMAN T'X22'E EXPANSION <br /> 4715 WEST VIEW DRIVE D�� Pt,�IEi�T OLPT. 4715 WEST VIEW DRIVE NEW MASTER BEDROOM <br /> HOME OWNER WITH WALK-IN CLOSET <br /> VANCE&ALEAS AESCHLEMAN_ EVERETT, WA 98203 AND BATHROOM. <br /> DAT <br /> E <br /> 4715 WEST VIEW DRIVE,EVERETT, WA DA I E 2- 1 2. 2-) TAX PARCEL NUMBER 006058-000-040-00 2.1 2. NEW WINDOW DORMERSFOR UPSTAIRS EXISTING <br /> 98203 DISTUI BD;AREAS LIMITED TO 3' BEYOND LOT # 40 OF VIEW ACRES DIV NO2 (6058) BEDROOMS <br /> PROPOSED ADDITIONS SECTION 32, TOWNSHIP 29N.W.B.L, RANGE 5E.W.M. <br /> PROJECT DESCRIPTION x EXCESS EXCAVATION OFF HAULED TO 3. CONTOURS PROVIDED <br /> PROPOSED 18'X 22'ADDITION TO 3.1. ELEVATION OF PROPOSED <br /> APPROVED COMMERCIAL FACILITY <br /> EXISTING HOME WITH TWO DORMERS Da O AO ., _ ADDITION AND <br /> MODIFICATIONS DO NOT <br /> EXCEED EXISTING HOUSE <br /> 14 <br /> ADDED TO EXISTING ROOF. ; STRUCTURELEGAL DESCRIPTION ■ 150'-0" 4. PROPOSED ADDITION U <br /> +�I- N ��a^1•«��:'�;•�' EXISTING UTILITIES INCLUDING <br /> LOT#40 OF VIEW ACRES DIV NO.2 (6058) 25 5 1t is owners responsibility to. e�ta�lish Wit; POWER,SEWER,FORCED <br /> WATER,WATER <br /> = HEATER AND FORCED AIR <br /> HVAC <br /> }.,'EXISTING.!:- .`• fro a �n�S SYSTEMS. <br /> PARCEL TAX ID# _ "•iCONCRETE rls E-m1 , <br /> 006058-000-040-00 gU El ':!'!?,!re AY:':• <br /> HEIGHT CALCULATIONSDF K r�,r�� ,�,� PROPANE TANKS, HEAT PUMPS AND r <br /> MANHOLE RIM ELEVATION=263.50 za o XISTING OTHER EQUIPMENT OR APP E TEt�AN. ES <br /> LEVEL BASE ELEV. OF HOUSE=260.50 pE 2021 i SHED s' MAY NOT BE LOCATED !N Th E EF C NT <br /> o r''r''�'`1' r I AND SIDE SET6ACKS. P.SOP kP E TANKS <br /> HEIGHT OF EXISTING HOUSE= 14.58' _ '� <br /> _� REQUIRE ADDITIONAL PERMITS RE DEP IUME NIT <br /> HEIGHT OF ADDITION MATCHES CITY O :: EXISTING SINGLE E SY THE EVERETT F <br /> 18,-5i• ' FAMILY RESIDENCE ROOF OVERHANG PRIOR TO INSTALLATION. <br /> EXISTING STRUCTURE. Pe m t Servic <br /> ELEV OF EXISTING AND ADDITION= ej° `5Ro SF :,-: ,w�..____ <br /> EXIST PAVER SIDEWALK �:�'- 60 BUILDING IS NOT P03TI'I1 S <br /> 275.08 LL_I ..........................' ;, z396 SF STRUCTUREADDITION y--7 <br /> Z I) IC A QED ON APPROVED SETS P;AAN, <br /> LOT COVERED BY BUILDINGS > w"'�sE 1, PROPOSED AbiNE W SITE PLAN SHALL BE `URTTbII7- <br /> LOT SIZE= 10,500SF 18X22 / TtD. '40 2 _ ' I� WILL <br /> EXISTING HOUSE= 1,285 SF ADDITION / � T_v� 3 � <br /> EXISTING SHED=200 SF W / /3996/�� M . vie �. PROJECT UNTIL TEE <br /> Cl) / REVI SITE PLAN HAS BEEN APPROV <br /> PROPOSED ADDITION=396 SF MANHOLE 24; �� qc) ED BY THE BUILDING-1M31,1Q WCRKS <br /> TOTAL LOT COVERAGE= 1,881 SF RIM ELEV <br /> SEWER SERVICE <br /> `L DEP1'i, <br /> LOT COVERED BY BUILDINGS= 18% 263.50 I3-4 COSTING GRAVEL PARKING .i:,z,A, -Asf -; . t4 ' V' <br /> QUANTIFIED SURFACES 1 260 — <br /> / .. <br /> TOTAL PROPOSED ROOF AREAS =500 SF ------H ,mpERVIDUs AREA P 150'-0" URBAN SITE PLAN No. Revision/Iaeus Date <br /> TOTAL OTHER HARD SURFACES =0 SF PROPOSED N 396 SF ` f <br /> PROPOSED DORMERS_ 0 SF 1 5 0 0 SINGLE FAMILY <br /> EXISTING STRUCTURE- 1285 SF <br /> IXISTNG DRIVEWAY 415 SF ` <br /> ft <br /> BREAKDOWN OF EXISIINc SIDEWALK- 60 SF LEGEND <br /> POLLUTION-GENERATING=0 SF °�'"c SHED 356 SF E EASEMENT LINE <br /> Z'S6 SF <br /> LINE <br /> NON POLLUTION GENERATING=0 SF RATIO IMPERVIOUS TO PERVIOUS-23% EX FENCE <br /> TOTAL PROPOSED ROOF AND OTHER - EX WATER SERVICE <br /> GROUND WIND DESIGN <br /> SNOW Speed Topographic Special Wind-borne SEISMIC DESIGN SUBJECT TO DAMAGE FROM WINTER ICE FLOOD AIR MEAN EX SIDE SEWER SERVICE <br /> SURFACES=500 SF Weathering Frost line Termite DESIGN UNDERLAYI� Ni HAZARDS FREEZING ANNUAL EXISTING CONCRETE :' '^4' ` ' "-i�:`? <br /> TOTAL LAND DISTURBING ACTIVITY= LOAD (mph) effects wind region debris zone CATAGORY depth TEMP REQUIRED INDEX TEMP PROPOSED ROOF AREA V///////t <br /> 25 110 NO NO NO D/D2 Moderate 18" Moderate 26F NO NO 175 50.5F Pwww Pew.wa w«+. <br /> 500 SF HOME REMODEL/EXPANSION <br /> ALEAS & TVIVANCE AESCHLEMAN <br /> SITE PLAN <br /> This approval only applies to E EVEER WEST VIEW 3 R ETT, WA 98203 <br /> the work beingperfo med unnder Additional Permits Are Required APPROVED <br /> Permit # � 1 d�,any pi For This To Include: THESEDOCUMENTS HAVE NOT BEEN PUBLIC S EP RTMENT <br /> - and does not recognize any Project <br /> existing structure that may not APPROVED FOR THE ISSUANCE OF -BY ----- -- 'ee <br /> 4715 ADDInON "" <br /> meet Zoning Code. 0 PlumbingSprinkler PUBLIC WORKS,MECHANICAL, FIRE /1�/2e,24 Me C '� <br /> ® DATE �¢ ( 01/29/2021 <br /> SUPPRESSION,ELECTRICAL OR CITY OF EVERET REV EWED FOR PERMIT <br /> %1 Mechanical 0 Fire Alarm PLUMBING PIRMITt : ` 20 SCALE <br /> Electrical <br />
The URL can be used to link to this page
Your browser does not support the video tag.