|
N AM MN WO MN MI NM r MI NM IIIIIIIII MN all MI IIIIIIII IIIIIIII IIIIIII a —
<br /> CONDUIT SCHEDULE CONDUIT SCHEDULE
<br /> TAG( /1) FROM TO SIZE CONDUCTORS NOTES TAG( #) FROM TO SIZE CONDUCTORS NOTES
<br /> GND MAIN CB GND RODS 3/4" #6 AWG CI CONTROL PANEL PUMP ROOM 1" SPARE
<br /> PI SNOPUD HIGHWAY PL MAIN SWITCHGEAR (3)4" (6)500 RCMII 5KV,(2)500 KCMIL N 1 SPARE CONDUIT,VIA VAULT C2 CONTROL PANEL PUMP ROOM 1" SPARE
<br /> P2 MAIN SWITCHGEAR A AIR A (2)4" (3)500 KCMIL SKV,(1)42 AWG G 1SPARE CONDUIT C3 CONTROL PANEL SURGE ANTICIPATORS 1" (24)PIA
<br /> P3 MAIN SWITCHGEAR A ATS B ] 2 3 500 KC 15KV P2A • ;E •N a U C4 CONTROL PANEL PRESSURE XDCR 1" (2)TWP#18
<br /> P4 ATS A SWITCHGEAR A (2)4" (3)500 KCMIL SKV,(1)#2 AWG G 1SPARE CONDUIT C5 CONTROL PANEL DOOR INTRUSION SWITCHES 1" (4)P14
<br /> PS ATS B SWITCHGEAR B (2)4" (3)500 KCMIL 5KV,(1)#2 AWG G I SPARE CONDUIT C6 CONTROL PANEL SMOKE DETECTORS 3/4" (4)#14
<br /> P6 FUTURE GENERATOR MTS I• A'C. D 5'A T C7 CONTROL PANEL FLOW METER 1" TWP AIR
<br /> P7 MTS XFMR GEN (6)4" (18)350 KCMIL,(6)350 REMIL N,(6)250 KCMIL G C8 CONTROL PANEL FLOW METER 1" (611114 FLOW TOTAL VAULT FLOOD
<br /> P8 KFMR GEN SWITCHGEAR GEN (2)4" (3)350 KCMIL SKV,(102 AWG A 1SPARE CONDUIT C9 CONTROL PANEL FUTURE GENERATOR 11/2"
<br /> P9 SWITCHGEAR GEN SWITCHGEARA 4" (3)350 KCMIL SKV,(1)#2 AWG G CEO CONTROL PANEL FUTURE GENERATOR 1"
<br /> PIO SWITCHGEAR GEN SWITCHGEAR B 4" (3)350 KCMIL SKV,(1)#2 AWG G C11 AGO#1 PUMP 1/1 MOTOR BEARINGS 3/4" (4)#14
<br /> P11 SWITCHGEAR B ASD#1 3" (3)P2/0 AWG 5KV,#4AWG G C12 ASO 111 PUMP II MOTOR THERMAL 3/4" (2)1114
<br /> P12 SWITCHGEAR A ASO#2 3" (3)#2/0 AWG SKV,#4AWG G C13 ASO 111 CONTROL PANEL 1" (8)#14
<br /> PIT SWITCHGEAR I ASD 113 3" (3)42/0 AWG SKV,N4AWGG C14 ASD01 CONTROL PANEL 1" (3)TSP P18
<br /> P14 SWITCHGEAR A ASD N4 3" (3)0/0 AWG 5KV,#4AWG G C15 A50#1 CONTROL PANEL 1" CAT SE
<br /> PI5 SWITCHGEARA ASD#5 3" (3)#2/0 AWG5KV,#4AWGG CI6 CONTROL PANEL PUMP 112 VALVES 1" (12)#I4 SOLENOIDS,PRESSURE SW,LIMIT SW
<br /> P16 SWITCHGEAR A XFMRA 3" (3)118 AWG 5KV,(UNTO G C21 ASD#2 PUMP#2 MOTOR BEARINGS 3/4" (4)1114
<br /> P17 SWITCHGEAR B XFMR A 3" (3)P8 AWG 5KV,(1)#10 G C22 ASD#2 PUMP 112 MOTOR THERMAL 3/4" (2)#14
<br /> P18 XFMRA PANEL A 4" (3)500 KCMIL(1)500 KCMIL N,#2 AWG G C23 AS0112 CONTROL PANEL 1" (8)N14
<br /> P19 PANELA PANELS 3" (3)#4/0 AWG,(1)4/0 AWG N,112 AWG G C24 ASP#2 CONTROL PANEL 1" (3)TSP P18
<br /> P20 SWITCHGEAR B WALL 3" SPARE C25 AGO N2 CONTROL PANEL 1" CAT SE
<br /> P21 ASO Al PUMP#1 MOTOR 3" (3)N2 AWG 5KV,#6 AWG G C26 CONTROL PANEL PUMP#3 VALVES 1" (12)#14 SOLENOIDS,PRESSURE SW,LIMIT SW
<br /> P22 ASO112 PUMP 112 MOTOR 3" (3)N2 AWG 5KV,B6 AWG G C31 ASO#3 PUMP 113 MOTOR BEARINGS 3/4" (4)1114
<br /> P23 ASD113 PUMP#3 MOTOR 3" (3)N2 AWG 5KV,1/6 AWG G C32 ASO#3 PUMP#3 MOTOR THERMAL 3/4" (2)414
<br /> P24 ASD#4 PUMP N4 MOTOR 3" (3)#2AWG SKV,N6 AWG G C33 ASO#3 CONTROL PANEL I" (8)#14
<br /> P25 ASO N5 PUMP AS MOTOR 3" (3)P2 AWG 5KV,N6 AWG G CM ASO P3 CONTROL PANEL 1" (3)TSP#18
<br /> P26 PUMP BUILDING ELECTRICAL BUILDING 3" SPARE C35 ASO#3 CONTROL PANEL 1" CAT 5E
<br /> P27 PUMP BUILDING ELECTRICAL BUILDING 3" SPARE CM CONTROL PANEL PUMP 114 VALVES 1" (12)#14 SOLENOIDS,PRESSURE SW,LIMIT SW
<br /> P28 C41 ASO N4 PUMP#4 MOTOR BEARINGS 3/4" (4)1114
<br /> P29 C42 A513#4 PUMP N4 MOTOR THERMAL 3/4" (2)#14
<br /> P30 PANELA FLOW METER CABINET 1" (2)1112 AWG,1/12 AWG G C43 ASD#4 CONTROL PANEL 1" (8)N14
<br /> P31 PANELA ASO Ill 1" (2)P1O AWG,#IOAWG G ASD CONTROL POWER C44 A50#4 CONTROL PANEL 1" (3)TSP N38
<br /> P32 PANELA ASD#2 I" (2)#10AWG,#10 AWG G ASD CONTROL POWER C45 A50#4 CONTROL PANEL 1" CAT SE
<br /> P33 PANELA ASD P3 1" (2)1110 AWG,PIOAWG G ASD CONTROL POWER C46 CONTROL PANEL PUMP#6 VALVES 1" (12)#14 SOLENOIDS,PRESSURE SW,LIMIT SW
<br /> P34 PANEL A ASO N4 1" (2)110 AWG,1110 AWG G ASD CONTROL POWER C51 ASO OS PUMP#S MOTOR BEARINGS 3/4" (4)#14
<br /> P35 PANELA ASO#5 1" (2)#10 AWG,P10AWG G AID CONTROL POWER C52 ASO NS PUMP N5 MOTOR THERMAL 3/4" (2)#14
<br /> P36 PANELA MTS 1" (2)#10 AWG,PIOAWG G PANEL HEATER C53 A50#5 CONTROL PANEL 1" (8)#14
<br /> R P37 PANELA FUTURE GENERATOR 1" FUTURE BATTERY CHARGER,RECEPTS CM ASO OS CONTROL PANEL 1" (3)TSP#I8
<br /> IP38 PANELA FUTURE GENERATOR 11/2" FUTURE OIL HEATERS C55 A50 NS CONTROL PANEL 1" CAT SE
<br /> P39 PANELA FLOW METER 1" (2)#10 AWG,#OOAWGG C56 CONTROL PANEL PUMP VALVES 1" (12)N14 SOLENOIDS,PRESSURE SW,LIMIT SW
<br /> g P40 C60 EX FIBER HANDHOLE COMM PANEL 3" EX FIBER
<br /> i CE1 COMM PANEL CAMERAS PUMP BUILDING 2" (6)CAT6(OUTSIDE PLANT)
<br /> TRANSFORMER SCHEDULE C62 COMM PANEL CAMERAS ELECT BUILDING 1" (2)CAT6
<br /> TAG KVA PRI SEC EFFICIENCY NOTES C63
<br /> 3 A 112.5 2400 V 2087/120Y 975% DOUBLE INCOMING LUGS C64 COMM PANEL HANDHOLE NI 2" FIBER OPTIC CABLE
<br /> R GEN 1500 480 V 2400V/ 975% STEP UP APPLICATION C65 CONTROL PANEL HANDHOLE PI 2" (24)1114
<br /> E C66 CONTROL PANEL HANDHOLE PI 2" (2)TSP P18
<br /> C67
<br /> k? MOTOR SCHEDULE C68 ATS A FUTURE GENERATOR 2" CAP BEYOND EDGE OF PAVEMENT
<br /> S TAG HP VOLT EFFICIENCY NOTES C69 ATSB FUTURE GENERATOR 2" P
<br /> ODU-1 (2)10 208V,3PH 94% C70 CONTROL PANEL ATS A 1" /(12)1114 ATS POSITION,SPARES
<br /> gS A ODU-2 (2)10 208V,3PH 94% C71 CONTROL PANEL AT5 B 1" 1(12)#14 ATS POSITION SPARES I
<br /> ID141 0.3 208V,1PH 92%
<br /> k IOU-2 0.3 208V,1PH 92%
<br /> IOU-3 0.3 208V,1PM 92%
<br /> IDU-4 0.3 208V,1PH 92%
<br /> E
<br /> &y
<br /> i 3 7 I E V E R E T T EVERGREEN PUMP STATION ELECTRICAL E11
<br /> a 0HC Consultants,t LLC
<br /> NO PDA E22 gpJrN gVU fNW OD.3�0 ... bhc, PUBLIC WORKS MODIFICATIONS
<br /> CONDUIT,TRANSFORMER
<br /> OM
<br /> s2oaa#4,5Pa1
<br /> ISSUED `"'' CONSULTANTS ....,.M,•m;N No, fhnf,W,z#2N, WORK ORDER UP3747-3 50
<br /> FF0k I T APRVD I ACIWNN1 ...._I RECORD._....._. K25.25rs433 ne,VE,Ignv
<br /> AcnoN DATE CONST DATE:APRVO nmoN DATE APRVf) _ . , AND MOTOR SCHEDULES 59
<br />
|