McClure & Sons Inc. 4/18/2022
>
Contracts
>
Capital Contract
>
McClure & Sons Inc. 4/18/2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2024 9:17:31 AM
Creation date
4/22/2022 10:59:16 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
McClure & Sons Inc.
Approval Date
4/18/2022
Council Approval Date
3/30/2022
Department
Public Works
Department Project Manager
Ryan Sass
Subject / Project Title
Evergreen Pump Station Modifications
Public Works WO Number
UP3747
Tracking Number
0003303
Total Compensation
$4,863,152.90
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
McClure & Sons Inc. 7/5/2022 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
McClure & Sons Inc. 7/5/2022 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
McClure and Sons, Inc. 11/21/2024 Change Order 3
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract\Capital Construction Contracts and Change Orders
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
900
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> Section 26 05 33 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS <br /> 5. Boxes and Enclosures: NEMA 250, Type 1, except use NEMA 250, Type I <br /> 4 stainless steel in damp or wet locations. <br /> C. Minimum Raceway Size: 3/4-inch (21-mm) trade size. I <br /> D. Raceway Fittings: Compatible with raceways and suitable for use and location. <br /> 1. Rigid Steel Conduit: Use threaded rigid steel conduit fittings unless I <br /> otherwise indicated. Comply with NEMA FB 2.10. <br /> 2. PVC Externally Coated, Rigid Steel Conduits: Use only fittings listed for I <br /> use with this type of conduit. Patch and seal all joints, nicks, and scrapes <br /> in PVC coating after installing conduits and fittings. Use sealant <br /> recommended by fitting manufacturer and apply in thickness and number <br /> of coats recommended by manufacturer. <br /> 3. EMT: Use compression fittings. Comply with NEMA FB 2.10. <br /> 4. Flexible Conduit: Use only fittings listed for use with flexible conduit. I <br /> Comply with NEMA FB 2.20. <br /> 3.02 INSTALLATION <br /> 111 <br /> A. Comply with NECA 1 and NECA 101 for installation requirements except where <br /> requirements on Drawings or in this article are stricter. I <br /> B. Complete raceway installation before starting conductor installation. <br /> C. Comply with requirements in Section 26 05 29 - Hangers and Supports for <br /> Electrical Systems for hangers and supports. <br /> D. Arrange stub-ups so curved portions of bends are not visible above finished slab. 1 <br /> E. Install no more than the equivalent of three 90-degree bends in any conduit run. <br /> Support within 12 inches (300 mm) of changes in direction. 111 <br /> F. Support conduit within 12 inches (300 mm)of enclosures to which attached. <br /> G. Raceways Embedded in Slabs: I <br /> 1. Run conduit larger than 1-inch (27-mm) trade size, parallel or at right <br /> angles to main reinforcement. Where at right angles to reinforcement, I <br /> place conduit close to slab support. Secure raceways to reinforcement at <br /> maximum 10-foot (3-m)intervals. <br /> 2. Arrange raceways to cross building expansion joints at right angles with I <br /> expansion fittings. <br /> 3. Arrange raceways to keep a minimum of 2 inches (50 mm)of concrete <br /> cover in all directions. <br /> H. Threaded Conduit Joints, Exposed to Wet, Damp, Corrosive, or Outdoor <br /> Conditions: Apply listed compound to threads of raceway and fittings before I <br /> making up joints. Follow compound manufacturer's written instructions. <br /> Cityof Everett 26 05 33-4 January2022 I <br /> Evergreen Pump Station Modifications <br /> UP3747-3 I <br />