h <br />pF WASy/,I,G� <br />CRITERIA: <br />1.1 ALL MATERIALS, NORKMAN5DIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWING5, <br />SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. <br />1.2 DESIGN LOADING CRITERIA: <br />ROOF LIVE LOAD (5NON), Pf 25 P5F <br />FLOOR LIVE LOAD (RESIDENTIAL) 40 P5F <br />RIND DESIGN CRITERIA: <br />(A5CE i-05, SECTION (5.4, METHOD I e 51MPLIFIED PROCEDURE) <br />1. ULTIMATE WIND SPEED (5®5EC GUST) 110 MPH <br />2. WIND IMPORTANCE FACTOR, IN 1.0 <br />5. FXP05URE B <br />4. INTERNAL PRF55URE COEFFICIENT N/A <br />5. COMPONENTS AND CLADDING REFER TO DRANIN65 <br />6. WIND 5PEED®UP FACTOR Kzt ® 1.00 <br />SEISMIC DESIGN CRITERIA. <br />I. SEISMIC USE GROUP 1 <br />2. 5E15MIC IMPORTANCE FACTOR IE ® 1.0 <br />5. MAPPED SPECTRAL ACCELERATION, SHORT PERIOD 5s ® 1.2g5 <br />4. MAPPED SPECTRAL ACCELERATION, Im5ECOND PERIOD 51 e 0.4611 <br />5. 51TE CLASS D <br />6. SPECTRAL RESPONSE COEFFICIENT, SHORT PERIOD 5D5 e 0.56 <br />i. 5PECTRAL RESPONSE COEFFICIENT, 1-5ECOND PERIOD 5D1 0.4c <br />5. SEISMIC DESIGN CATEGORY D <br />q. BA51C 5EI5MIC-FORCE®RE515TANCE 5Y5TEM PLYWOOD SHEAR WALL5 <br />10. RE516N BASE SMEAR V o 2.6 KIPS (ADDITION ONLY) <br />11. SEISMIC RESPONSE COEFFICIENT as ® 0.15W <br />12. RESPONSE MODIFICATION FACTOR R ® (0.5 <br />15. ANALY515 PROCEDURE USED EGUIV. LATERAL FORCE (A5CE 01.5.5) <br />1.5 STRUCTURAL 2RAWIN65 SHALL BE USED IN CONJUNCTION KITH ALL OTHER PROJECT DOCUMENTS FOR <br />BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR <br />COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. <br />1.4 CONTRACTOR SMALL VERIFY ALL EXISTING DIMEN51ON5 AND CONDITIONS PRIOR TO COMMENCING <br />ANY WORK. DIMENSIONS OF EXISTING CONDITION5 5HONN ON THE DRAWIN65 MUST BE VERIFIED. <br />1.5 CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL <br />COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE SEEN COMPLETED IN ACCORDANCE WITH THE <br />DRAM I NG5. <br />1.6 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, <br />TECHNIQUES, 5EQUENCE5 OR PROCEDURES REQUIRED TO PERFORM THE NORK. <br />I.i CHANGES TO THESE DRANIN65 THAT AFFECT THE STRUCTURAL DESIGN ARE THE RESPONSIBILITY OF <br />THE CONTRACTOR. THE ENGINEER SHOULD BE INFORMED OF ANY STRUCTURAL CHANGES. <br />1.5 DRANIN65 INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. NHERE CONDITIONS ARE <br />NOT SPECIFICALLY INDICATED BUT ARE OF 51MILAR CHARACTER TO DETAILS 5HONN, 51MILAR <br />DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEN AND APPROVAL BY THE ARCHITECT <br />AND THE STRUCTURAL ENGINEER. <br />I.q ALL STRUCTURAL 5Y5TEM5 6OMP05ED OF COMPONENTS TO BE FIELD ERECTED SHALL ICE <br />5UPERVI5ED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND <br />ERECTION IN ACCORDANCE KITH INSTRUCTIONS PREPARED BY THE SUPPLIER. <br />1.10 SEISMIC BRACING OF MECHANICAL UNITS AND OTHER MECHANICAL FIXTURES NOT SPECIFICALLY <br />5HONN ON THE PROJECT MECHANICAL DRAWINGS SHALL BE DESIGNED BY A PROFF-55IONAL <br />ENGINEER REGISTERED IN THE STATE OF WA5HIN6TON. THE MECHANICAL CONTRACTOR MUST WIRE THE <br />ENGINEER AND IS RESPONSIBLE FOR ALL COSTS RELATED TO THE PURCHASE AND INSTALLATION OF <br />SEISMIC BRACING. <br />1.11 DEFERRED SUBMITTALS: SHOP DRAWINGS FOR DEFERRED SUBMITTAL ITEMS SHALL INCLUDE THE <br />DESIGNING PROFF55IONAL ENGINEER'S STAMP, STATE OF NASHINGTON, AND SHALL BE APPROVED BY <br />THE COMPONENT DESIGNER PRIOR TO CURSORY REVIEN BY THE ENGINEER OF RECORD FOR LOADS <br />IMPOSED ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER 15 RESPONSIBLE FOR CODE <br />CONFORMANCE AND ALL NECESSARY CONNECTIONS NOT SPECIFICALLY CALLED OUT ON <br />ARCHITECTURAL OR STRUCTURAL DRANIN65. DEFERRED SUBMITTALS SHALL INDICATE MAGNITUDE <br />AND DIRECTION OF ALL LOADS IMPOSED ON BASIC STRUCTURE. DESIGN CALCULATIONS SHALL BE <br />INCLUDED IN THE SUBMITTAL. THE ARCHITECT SHALL FORNARD ALL REVIEWED DEFERRED <br />SUBMITTALS TO THE BUILDING OFFICIAL FOR APPROVAL. <br />1.12 SPECIAL INSPECTION SHALL ICE 5UPERVI5ED IN ACCORDANCE KITH SECTION Ii04 OF THE IbC BY A <br />QUALIFIED TESTING AGENCY DESIGNATED BY THE ARCHITECT. THE ARCHITECT AND ENGINEER SHALL <br />BE FURNISHED KITH COPIES OF ALL INSPECTION REPORTS AND TEST RESULTS. SPECIAL INSPECTION <br />SHALL BE PERFORMED ON CAST IN PLACE CONCRETE NALL5. <br />1.15 CHAN6E5 TO THESE PRANIN65 THAT AFFECT THE STRUCTURAL DE516N ARE THE RE5PON51BILITY OF <br />THE CONTRACTOR. THE ENGINEER SHALL BE INFORMED OF ANY STRUCTURAL CHANGES ONCE <br />RECEIVED STRUCTURAL CHANGES HILL BE SUBMITTED TO THE CITY FOR APPROVAL. <br />6E0TEGHNIGAL: <br />2.1 FOUNDATION NOTES: ALLONABLE 501L PRESSURE, LATERAL EARTH PRESSURE, AND SOIL PROFILE <br />TYPE ARE ASSUMED AND THEREFORE MUST BE VERIFIED. IF SOILS ARE FOUND TO BE OTHER THAN <br />ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR P0551BLE FOUNDATION REDESIGN. FOOTINGS <br />SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 15" BELON ADJACENT FINISHED GRADE. <br />UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELON COLUMNS OR HALLS ABOVE. <br />BACKFILL BEHIND ALL RETAINING HALLS KITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR <br />SU55URFACE DRAINAGE. <br />ALLONABLE SOIL PRESSURE 1500 P5F <br />2.2 EXPANSION BOLTS INTO CONCRETE SHALL BE "NFDGE®ALL", AS MANUFACTURED BY SIMPSON <br />5TRON6®TIE AND INSTALLED IN STRICT ACCORDANCE NITH ICC REPORT NO. ER®5651, INCLUDING <br />MINIMUM EMBEDMENT REQUIREMENTS. SUBSTITUTES PROPOSED BY CONTRACTOR SMALL BE SUBMITTED <br />FOR REVIEN KITH ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. IN <br />ADDITION, FOR WIND OR SEISMIC APPLICATIONS, SUBSTITUTIONS SHALL MEET ICC ACCEPTANCE <br />CRITERIA A601. SPECIAL INSPECTION 15 REQUIRED FOR ALL EXPANSION BOLT INSTALLATION. <br />EXPANSION BOLTS SMALL NOT BE USED AS SUBSTITUTES FOR EMBEDDED ANCHOR BOLT5 UNLE55 <br />SPECIFICALLY APPROVED BY THE STRUCTURAL ENGINEER. <br />2.5 DRIVE PINS AND OTHER PONDER -ACTUATED FASTENERS SHALL BE ITN RAMSET/RED BEAD LOIN <br />VELOCITY TYPE (5ERIE5 1500, 0.14" DIAMETER UNLE55 OTHERWI5E NOTED), OR AN APPROVED <br />EQUIVALENT IN STRENGTH AND EMBEDMENT. INSTALL IN STRICT ACCORDANCE NITH 1650 REPORT NO. <br />165q. MINIMUM EMBEDMENT IN CONCRETE SHALL BE I" UNLESS OTHERWISE NOTED. MAINTAIN AT <br />LEAST 5" TO NEAREST CONCRETE EDGE. <br />2A EPDXY -GROUTED RODS OR REBAR TO CONCRETE SPECIFIED ON THE DRAWIN65 SHALL BE GROUTED <br />KITH "SET EPDXY -TIE ADHESIVE" AS MANUFACTURED BY 51MP50N 5TRON6-TIE. INSTALL IN STRICT <br />ACCORDANCE WITH ICC REPORT NO. 52114, INCLUDING MINIMUM EMBEDMENT REQUIREMENT5. <br />SUBSTITUTES PROP05ED BY CONTRACTOR SHALL BE SUBMITTED FOR REVIEW KITH ICC REPORTS <br />INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. IN ADDITION, FOR WIND OR SEISMIC <br />APPLICATIONS, 5U355TITUTION5 SHALL MEET ICC ACCEPTANCE CRITERIA AC55. SPECIAL INSPECTION <br />OF EPDXY -GROUTED ANCHOR INSTALLATION 15 REQUIRED. <br />G0Nr.,ETE: <br />5.1 CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE KITH IBC <br />SECTION IgO5 AND ACI 501. CONCRETE SHALL ATTAIN A 25-DAY STRENGTH OF f'c ® 2,500 PSI AND <br />MIX SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. <br />5.2 REINFORCING STEEL SHALL CONFORM TO A5TM A615, GRADE 60, fy = 60,000 P51. EXCEPTIONS <br />BARS SPECIFICALLY NOTED AS SUCH ON THE DRANIN65 SHALL ICE GRADE 40, fy ® 40,000 P51. <br />WELDED WIRE FABRIC SHALL CONFORM TO ASTM A155. <br />5.5 REINFORCING STEEL SHALL BE DETAILED (INCLUDING DOOK5 AND BENDS) IN ACCORDANCE WITH ACI <br />515-cllci AND 515-02. LAP ALL CONTINUOUS REINFORCEMENT 2'-0" MINIMUM. PROVIDE CORNER BAR5 <br />AT ALL WALL AND FOOTING INTERSECTIONS AND LAP 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL <br />BE MADE IN ACCORDANCE WITH ACI 515®5q, CLASS B. LAP ADJACENT MATS OF WELDED WIRE <br />FABRIC A MINIMUM OF 5" AT SIDES AND ENDS. <br />5.4 CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLON5: <br />FOOTIN65 AND UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXP05ED TO EARTH 5" <br />FORMED SURFACES EXPOSED TO EARTH OR FATHER (6 BAR5 OR LARGER) 2" <br />(5 BARS OR SMALLER.) ! //2" <br />5.5 CA5T-IN-PLACE CONCRETE: SEE ARCHITECTURAL DRANIN65 FOR EXACT LOCATIONS AND <br />DIMENSIONS OF DOOR AND NINDOW OPENINGS IN ALL CONCRETE WALLS. SEE MECHANICAL <br />DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL OPENING5 THROUGH CONCRETE <br />HALLS. SEE ARCHITECTURAL PRANIN65 FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, <br />COLOR, TEXTURE, AND OTHER FIN15H DETAILS AT ALL EXPOSED CONCRETE SURFACES. <br />STEEL: <br />5.1 STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON THE LATEST EDITIONS <br />OF THE A.I.S.C. 5PECIFICATION5 AND CODES: <br />I. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS®ALLONAISLE 5TRE55 AND PLASTIC DESIGN, OR <br />LOAD AND RESISTANCE FACTOR DE516N SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS. <br />2. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, ADOPTED JUNE 10, 1ga2, <br />AMENDED BY THE DELETION OF THE FOLLOWING PHRASE IN PARAGRAPH 4.2.1: "THIS APPROVAL <br />CON5TITUTE5 ACCEPTANCE BY THE ONNER'5 AUTHORIZED REPRESENTATIVE OF DE51GN <br />RESPONSIBILITY FOR THE STRUCTURAL ADEQUACY OF SUCH CONNECTIONS." <br />5.2 STRUCTURAL STEEL INCLUDING PLATES, ANGLES, AND RODS, SHALL CONFORM TO A5TM A56, Fy w 56 <br />K51. STEEL 5HAPES SHALL CONFORM TO A5TM A5i2, Fy ® 50 KSI. STEEL PIPE SHALL CONFORM TO <br />ASTM A55, TYPE E OR 5, GRADE B, Fy a 55 KSI. STRUCTURAL TUBING SMALL CONFORM TO ASTM <br />A500, GRADE 5, Fy o 46 K51. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO A5TM <br />A501. <br />5.5 DIMEN51ONAL TOLERANCE FOR STRUCTURAL STEEL MEMBERS SHALL 5E PER THE A156 CODE OF <br />STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, SECTION 6.4 AND ASTM SPECIFICATION <br />Ab. UNLE55 SPECIFICALLY ALLONED BY THE ENGINEER, COLUMN MEMBERS SHALL NOT BE MODIFIED <br />BY THE ROTARY STRAIGHTENING PROCESS. <br />5.4 ARCHITECTURALLY EXPOSED STRUCTURAL, STEEL SHALL CONFORM TO SECTION 10 OF THE A.I.S.C. <br />CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, ADOPTED JUNE 10, 1gg2. ANY <br />STEEL THAT 15 TO BE EXP05ED TO VIEN UPON COMPLETION OF THE PROJECT SHALL BE CONSIDERED <br />ARCHITECTURALLY EXP05ED.T. <br />5.5 ALL MELDING SHALL BE IN CONFORMANCE NITW A.I.5.0. AND A.N.5. STANDARDS .AND SHALL BE <br />PERFORMED 5Y N.A.S.O. CERTIFIED NELDER5 USING F IOXX ELECTRODES. ONLY PREOUALIFIED <br />NELD5 (AS DEFINED BY A.N.S) SHALL BE USED. MELDING OF GRAVE 60 REINFORCING BARS OF <br />REQUIRED) SHALL BE PERFORMED USING LON HYDROGEN ELECTRODES. WELDING OF GRADE 40 <br />REINFORCING BAR5 (IF REQUIRED) SMALL BE PERFORMED USING EiOXX ELECTRODES. WELDING <br />NITHIN 4" OF COLD BENDS IN REINFORCING STEEL 15 NOT PERMITTED. SEE REINFORCEMENT NOTE <br />FOR MATERIAL REQUIREMENTS OF WELDED BARS. <br />\®op: <br />6.1 FRAMING LUMBER SHALL BE KILN DRIED OR MC-101, AND GRADED AND MARKED IN CONFORMANCE <br />NITD N.C.L.B. STANDARD GRADING RULES FOR NEST COAST LUMBER NO. 1-7. FURNISH TO THE <br />FOLLONIN% MINIMUM STANDARDS: <br />JOISTS, BEAM5, 5TRINGER5 4 LEDGERS: <br />(2x MEMBERS) HEM -FIR NO. 2 <br />Fb ® 55O P51, Fv e 150 P51, Pape 405, E 1500 KSI <br />(4x MEMBERS) DOUGLAS FIR -LARCH NO. 2 <br />Fb ® qOO P51, Fv 150 P51, Fcp o 625, E o 1600 K51 <br />(BUILT-UP 2x BEAMS) HEM -FIR NO. 2 <br />Fb ® 550 P51, Fv 150 PSI, Pap 405, E = 1500 K51 <br />((ox � LARGER MEMBERS) DOUGLAS FIR -LARCH NO. 2 <br />Fb m 0,75 PSI, Fv ® 1,70 PSI, Fop 625, E o 1500 K51 <br />POSTS: (4x MEMBERS) HEM -FIR NO. 2 <br />Fa e 1500 PSI, Fb e 550 PSI, E 1500 K51 <br />(bx 4 LARGER MEMBERS) DOU6LA5 FIR -LARCH NO. 2 <br />Fc a i00 P51, Fb 150 P51, F o 1500 K51 <br />(BUILT-UP 2x POSTS) HEM -FIR NO. 2 <br />Fb e 550 PSI, Fv o 150 P51, Pap o 405, E = 1500 K51 <br />6.2 GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH A5TM AND A.I.T.C. <br />STANDARDS. EACH MEMBER SHALL BEAR AN A.I.T.C. IDENTIFICATION MARK AND 5HALL BE <br />ACCOMPANIED BY AN A.I.T.C. CERTIFICATE OF CONFORMANCE. FURNI5H TO THE FOLLOWING MINIMUM <br />STANDARDS: <br />SIMPLE SPAN BEAMS: DOUGLAS FIR COMBINATION 24F®V4 <br />Fb 6 2400/1500 PSI, Fv a 240 PSI, E ® 1500 KSI <br />CAMBER ALL GLULAM BEAMS TO 5,500' RADIUS, UNLE55 OTHERN15E NOTED. GLUED LAMINATED <br />MEMBERS EXP05ED TO WEATHER OR MOISTURE SHALL BE TREATED KITH AN APPROVED <br />PRESERVATIVE. <br />w®®D CONT.: <br />6.5 ENGINEERED WOOD SMALL BE MANUFACTURED UNDER A PROCESS APPROVED BY THE NATIONAL <br />RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE NAME AND PLANT <br />NUMBER OF THE MANUFACTURER, THE GRADE, THE NER REPORT NUMBER, AND THE QUALITY CONTROL <br />AGENCY. ALL ENGINEERED NOOD SHALL ICE MANUFACTURED IN ACCORDANCE WITH THE NATIONAL <br />EVALUATION SERVICE, INC., REPORT NO. NER®451. ALL MEMBERS SHALL BE MANUFACTURED KITH A <br />NATERPROOF ADHE51VE MEETING THE REQUIREMENTS OF ASTM D255q NITH ALL STRANDS ORIENTED <br />PARALLEL KITH THE LENGTH OF THE MEMBER. FURNISH TO THE FOLLOWING MINIMUM STANDARDS! <br />BEAMS: <br />LAMINATED STRAND LUMBER (L,SL) <br />Fb ® 2525 PSI, Fv 510 P51, E 1550 K51 <br />Fb = 1100 PSI, Fv 400 P51, E 1500 K51 (DEPTH < -0//") <br />LAMINATED VENEER LUMBER (LVL) <br />Fb m 2600 PSI, Fv ® 255 P51, E ® IgOO K51 <br />PARALLEL STRAND LUMBER (P5L) <br />Fb o 2gOO P51, Fv = 2qO P51, E g 2000 K51 <br />RIM BOARD: <br />LAMINATED STRAND LUMBER (L5L) <br />Fb = MOO P51, Fv ® 255 P51, E a 1500 KSI <br />DESIGN 5HONN ON THE DRANIN65 15 BASED ON LUMBER MANUFACTURED BY TRU5®JO15T MACMILLAN. <br />ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO RFVIEW AND APPROVAL BY THE ARCHITECT <br />AND STRUCTURAL ENGINEER. ALL DANGERS AND OTHER HARDNARE NOT 5DOWN SHALL BE DF-516NF-D <br />AND SUPPLIED BY THE JOIST MANUFACTURER. <br />6.4 DECKING SMALL BE IN ACCORDANCE KITH AITC 112®015. FURNISH TO THE FOLLOWING MINIMUM <br />STANDARDS: <br />DOUGLAS FIR -LARCH OR DOUGLAS FIR -LARCH (NORTH) COMMERCIAL QUALITY <br />MINIMUM BA510 DESIGN 5TRE55 <br />Fb ® 1650 P51, E m MOO K51 <br />6.5 PREFABRICATED CONNECTOR PLATE WOOD ROOF AND FLOOR TRUSSES SMALL ICE DESIGNED 5Y THE <br />MANUFACTURER 1N ACCORDANCE KITH TPI 1-2001 FOR THE 5PAN5 AND CONDITIONS 5HONN ON THE <br />DRAWINGS. WOOD TRU55E5 SHALL UTILIZE APPROVED CONNECTOR PLATES (MITEK, ITN OR OTHER <br />APPROVED TRU55 PLATE MANUFACTURER). UNLE55 OTHERWISE NOTED, LOADING SHALL BE AS <br />FOLLOWS: <br />ROOF LOADING <br />TOP CHORD LIVE LOAD IN ACCORDANCE KITH CRITERIA SECTION (SNOW OR ROOF LIVE LOAD) <br />BOTTOM CHORD LIVE LOAD IN ACCORDANCE NITW CRITERIA SECTION (ATTIC LOAD) <br />TOP CHORD DEAD LOAD 10 P5F <br />BOTTOM CHORD DEAD LOAD 5 P5F <br />NI ND UPLIFT (TOP CHORD) 15 PSF <br />FOR TRUSSES SPANNING 60-FEET OR GREATER, THE ONNER SHALL CONTRACT KITH ANY QUALIFIED <br />REGISTERED DESIGN PROFESSIONAL FOR THE DESIGN OF THE TEMPORARY INSTALLATION <br />RE5TRAINT/BRACIN6 AND THE PERMANENT INDIVIDUAL TRU55 MEMBER RE5TRA I NT/BRAC I NG. A <br />PRECONSTRUCTION MEETING SHALL BE ARRANGED INCLUDING THE ENGINEER, TRUSS MANUFACTURER, <br />CONTRACTOR, FRAMING SUPERVISOR, AND CRANE OPERATOR TO REVIEN THE HANDLING, <br />INSTALLATION AND BRACING PRIOR TO DELIVERY OF TRUSSES. <br />6.6 ROOF, FLOOR 4 NALL 5HEATHIN6 SHALL BE APA RATED, EXTERIOR OR EXPOSURE I PLYWOOD OR <br />055. SHEATHING SHALL BE MANUFACTURED UNDER THE PROVISIONS OF VOLUNTARY PRODUCT <br />STANDARDS DOC P5®1 OR DOC P5®2, OR APA PRP-105 PERFORMANCE 5TANDARD5 AND POLICIES <br />FOR STRUCTURAL USE PANELS. SEE DRAWINGS FOR THICKNE55, SPAN RATING, AND NAILING <br />REQUIREMENTS. UNLESS OTHERWISE NOTED, NALL SHEATHING SHALL BE 1/2" (NOMINAL) KITH SPAN <br />RATING OF 24/0. GLUE FLOOR SHEATHING TO ALL SUPPORTING MEMBERS KITH ADHESIVE <br />CONFORMING TO APA SPECIFICATION A176@01. <br />6.1 ALL WOOD PLATES IN DIRECT CONTACT NITD CONCRETE OR MA50NRY SHALL BE PRE55URE-TREATED <br />NITH AN APPROVED PRESERVATIVE. PROVIDE 2 LAYERS OF ASPHALT- IMPREGNATED BUILDING <br />PAPER ISETNEEN UNTREATED LEDGERS, BLOCKING, ETC., AND CONCRETE OR MASONRY, <br />6.5 TIMBER CONNECTOR5 SHALL BE "STRONG -TIE" BY 51MP50N COMPANY, AS SPECIFIED IN THEIR <br />CATALOG NO, 0®2006. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY <br />MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE KITH THE MANUFACTURER'S <br />INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, CENTER STRAP ON JOINT AND <br />PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER, NITH EQUAL NUMBER <br />AND SIZE OF FASTENERS IN EACH MEMBER. <br />TIMBER CONNECTORS IN CONTACT KITH TREATED NOOD SHALL BE ZMAX/HDG OR 5TAINLE55 5TEEL <br />AND THE FA5TENER5 SHALL BE GALVANIZED IN ACCORDANCE KITH A5TM A155 OR 5TAINLE55 STEEL. <br />(NOOD TREATED KITH ZINC BORATE EXEMPT.) <br />&A BOLT5 AND LAG SCREN5 IN HOOD MEMBERS SHALL CONFORM TO A5TM A50,7. THREADED RODS <br />SHALL CONFORM TO ASTM A56. PROVIDE NA5HER5 UNDER THE BEADS AND NUTS OF ALL BOLTS, <br />ROD5 AND LAG SCREN5 BEARING ON HOOD INSTALLATION OF BOLTS SHALL CONFORM TO 2001 <br />ND5 SECTION 11.1.2, AND INSTALLATION OF LAG 5CREN5 SHALL CONFORM TO 2001 ND5 SECTION <br />NAILING: ALL NAILS SPECIFIED ON THE SHALL BE AS FOLLON5: <br />FRAMING NAILS: 0.151 "'P x 5V4" <br />SHEATHING NAILS: 0.15I"-p x 26, <br />DECKING NAILS: 0.162"41 x 5/2" <br />ALL METAL FASTENERS IN CONTACT KITH TREATED NOOD SHALL BE OALVANIZED IN ACCORDANCE <br />NITD A5TM A155 OR 5TAINLF-55 STEEL. (HOOD TREATED KITH ZINC BORATE EXEMPT.) <br />6.10 HOOD FRAMING NOTES: THE FOLLOWING APPLY UNLESS OTHER.NISE NOTED ON THE DRAWINGS: <br />A. ALL NOOD FRAMING DETAILS SHALL ICE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE I15C. <br />MINIMUM NAILING SHALL CONFORM TO IBC TABLE 2504.q.1 OR NER®212. COORDINATE THE 51ZE <br />AND LOCATION OF ALL OPENINGS KITH MECHANICAL AND ARCHITECTURAL DRANINGS. <br />B. NALL FRAMING: ALL STUD NALL5 SHALL BE 2x4 STUDS ® 16"®c. AT INTERIOR NALL5 AND 2xb <br />16"®c AT EXTERIOR WALLS. TNO STUDS MINIMUM SHALL BE PROVIDED AT THE ENDS OF ALL <br />NALL5, AT EACH SIDE OF ALL OPENINGS, AND AT THE ENDS OF ALL BEAMS AND HEADERS. (2) <br />2x5 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS. SOLID BLOCKING FOR HOOD <br />COLUMNS <br />SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELON. <br />ALL STUD NALL5 SHALL HAVE THEIR LONER NOOD PLATES ATTACHED TO HOOD FRAMING <br />{5ELON <br />KITH FRAMING NAILS AT 12" ®c 5TA66ERED OR BOLTED TO CONCRETE KITH 5/5" DIAMETER <br />ANCHOR BOLTS (EMBED 1") @ 6®0"®c. INDIVIDUAL MEMBERS OF 15UILT®UP STUD POSTS SHALL ICE <br />NAILED TO EACH OTHER NITD FRAMING NAILS ® 12"®c STAGGERED. <br />C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT <br />EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR <br />ROOFS. PROVIDE BRIDGING @ 5'®O"oc AND 50LID BLOCKING AT ALL BEARING POINTS. <br />TOENAIL <br />.JOISTS TO SUPPORTS KITH TWO FRAMING NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR <br />BEAMS KITH SIMP50N METAL JOIST HANGERS IN ACCORDANCE KITH NOTES ABOVE. NAIL ALL <br />MULTI -JOIST BEAMS TOGETHER V41TH FRAMING NAILS ® 12"®c STAGGERED. <br />ROOF AND FLOOR SHEATHING SHALL BE LAID UP KITH GRAIN <br />PERPENDICULAR TO SUPPORTS AND <br />NAILED KITH 5d NAILS ® 6"®c TO FRAMED PANEL EDGES AND OVER STUD WALL AS 5HONN ON <br />THE DRANING5 AND ® 12"®c (10"oc AT FLOORS) TO INTERMEDIATE SUPPORTS. PROVIDE <br />APPROVED PANEL EDGE CLIPS CENTERED BETNEEN JOI5T5/TRU55E5 AT UNBLOCKED ROOF <br />SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED <br />TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED NITW 50LID BLOCKING. ALLOW I/5" <br />SPACING AT ALL PANEL ED6E5 AND ENDS OF FLOOR AND ROOF SHEATHING. TOENAIL <br />BLOCKING <br />TO SUPPORTS KITH FRAMING NAILS ® 12"®r. AT BLOCKED FLOOR AND ROOF DIAPHRAGMS, <br />PROVIDE FLAT 2x BLOCKING AT ALL UNFRAMED PANEL EDGES AND NAIL NITH EDGE NAILING <br />SPECIFIED. <br />w <br />W <br />()w <br />W <br />W� <br />WCL <br />w <br />w <br />I- <br />U z <br />C6 W <br />w <br />w <br />�_:E <br />TW <br />C� <br />t LL. <br />0-0 <br />®� <br />w� <br />®0 <br />00 <br />()U) <br />ww <br />ww <br />00 <br />zz <br />:7)® <br />h <br />�0 <br />n_ <br />�w <br />c3 � <br />w0 <br />tw <br />Y_U) <br />0� <br />Ix® <br />w <br /><® <br />(no <br /><� <br />0< <br />I— Z <br />0:7) <br />W <br />0� <br />�LL, <br />3® <br />0 <br />�Z <br />I- <br />®F <br />�0 <br />�w <br />�0 <br />U� <br />ww <br />W) <br />D 0 <br />w� <br /><0 <br />®0 <br />�< <br />�:7) <br />I� ® papyy <br />/<q N <br />N) <br />0 <br />Z eJ <br />®® <br />wz <br />U� <br />w® <br />F-Q <br />U) <br />z <br />L0 <br />w <br />w <br />,p 33029 p <br />FG/STERN <br />A1, <br />I► <br />Or) L0 <br />Lu <br />fia <br />µ <br />- <br />�< <br />.. <br />ml <br />q <br />Li <br />C) <br />w <br />C) <br />ial <br />C) <br />N <br />00 <br />co <br />0 <br />C <br />0 <br />