LAMENTATED COMPOSITION ROOFING TO MATCH EXISTING <br />OVER 30# FELT UNDERLAYMENT OVER 1/2" PLYWD OR OSB <br />SHEATHING. DOUBLE UNDERLAYMENT WHEN SLOPE IS LESS <br />THAN 4:12 ROOF FRAMING PER PLAN. ALL TRUSSES <br />TO BE STAMPED BY WASHINGTON STATE ENGINEER. VENTED <br />BIRD BLOCKING BETWEEN EACH TRUSS/RAFTER. <br />SKYLIGHTS PER PLAN U .50 (MAX.) <br />CEILING INSULATION R49 OR R38 PER 2015 WASHINGTON STATE <br />ENERGY CODE. PROVIDE AIR BAFFEL BETWEEN INSULATION <br />AND ROOF SHEATHING. THE THICKNESS OF BLOWN -IN OR SPRAYED <br />ROOF/CEILING INSULATIO%IBERGLASS OR CELLULOSE) SHALL BE <br />WRITTEN IN INCHES ON MARKERS THAT ARE INSTALLED AT LEAST <br />ONE FOR EVERY 300 SUARE FEET THROUGHOUT THE ATTIC SPACE. <br />USE 5" CONTINUOUS ALUMINUM <br />TIES OR EQUAL (TYP) ON ALL° O.C. <br />VENTED BIRD BLOCK <br />SOLID BLOCKING' <br />BETWEEN RAFTERS <br />OR TRUSSES <br />LAP SIDING TO MATCH EXISTING OVER <br />ASPHALT SATURATED FELT (14# MIN) <br />OR BUILDING WRAP OVER OSB OR <br />PLYWD SHEATHING THICKNESS & <br />NAILING PER ENGINEERING <br />ANCHOR BOLTS W/3" SQ WASHERS <br />PER IRC R403.1.6.1 <br />PER <br />SIMPSON HURRICANE <br />�— BAFFEL <br />(2) 2x 6 PLATES <br />6 <br />DOUBLE TOP PLATES <br />8' 1-1/8" PL. HT. OR PER F <br />HEADERS AS PER PLAN <br />R10 PER <br />WSEC 2018 <br />314 SUBFLOOR <br />WINDOWS AS PER PLAN <br />U-VALUE PER PER PLAN TO <br />COMPLY WITH 2O18 WSEC <br />VINYL TO MATCH EXISTING <br />R21INSULATION <br />W BONINTERIORER2018 HEIGHTS PLAN <br />R21 - EXTERIOR WALL INSULATION PER WSEC <br />R30 INSUL AT VAULTED <br />CEILINGS PER 2018 WSEC <br />BEAMS PER PLAN <br />+--- 2x 6 INSUL. WALL <br />2x 10 DF#2 JOISTS <br />SINGLE BOTTOM 2 6 P.T. PLATE <br />314" PLYWOOD SUBFLOOR - GLUED & NAILED. <br />JOISTS PER PLAN. R38 INSUL. PER 2018 WSEC <br />UNDER FLOORS ABOVE UNHEATED AREAS. <br />TYP. WALL SECTION <br />1 /2" = 1' 0" <br />WHILE KEY DESIGN, INC. HAS MADE EFFORT TO ENSURE THE ACCURACY <br />OF CLIENT FROM 2DIFL©bRPtANS INC. <br />LT THEIBUILDER SHALL CHECK ANDED BY D E <br />VERIFY ALL DIMENSIONS & COMPLIANCE TO APPLICABLE CODES PRIOR <br />TO CONSTRUCTION. <br />© Key Design, Inc - 2021 <br />NOTE: <br />FRAME POCH ROOF USING <br />MANUF. SCISSOR TRUSSES @ 24" O.C. <br />SEE DETAIL A <br />ROOF FRAMING / ATTICS <br />IRC R802.10.2 Trusses must be designed by a registered design professional, in accordance with <br />ANSIITP11 standards. <br />IRC R802.10.3 Trusses must be braced to prevent lateral rotation and provide lateral stability in <br />accordance with the individual truss design drawings. <br />IRC R802.10.4 Truss members must not be cut, notched, drilled, spliced or otherwise altered in any way <br />without the approval of a registered design professional. Alterations resulting in the addition of <br />loads that exceed the design load for the truss will not be permitted without verification that the <br />truss is capable of supporting such additional loading. <br />IRC R802.3 Ridge board: Minimum 1" thickness. Valley or hip rafter: Minimum 2" thickness. Minimum <br />depth not less than the cut end of the rafter. <br />IRC R803.2.1.1 Plywood roof sheathing, if exposed on underside, must exterior grade or assembled with <br />exterior glue meeting an "Exposure 1" rating. <br />IRC R806.1 & R806.2 Enclosed attic and rafter spaces must have cross ventilation for each separate <br />space by vent openings protected against the entrance of rain and snow. The net free vent area <br />may not be less than 1 /150 of the space ventilated. <br />Exception: The area may be 1/300, provided at least 50 percent and not more than 80 percent <br />of the required vents are in the upper portion of the space and at least 3' above eave <br />vents or if a vapor barrier with a one pens maximum rating is applied to the warm side of <br />the ceiling. The openings must be covered with corrosion -resistant 1/4" screen. <br />DETAIL A <br />PORCH TRUSS <br />! 8' 1-1/8" ABOVE SUBFOOR <br />-3 (PG 7-9) <br />SECTION R806 <br />ROOF VENTILATION <br />R806.1 Ventilation required. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the <br />underside of roof rafters shall have cross ventilation for each separate space by ventilatingg openings protected against the <br />entrance of rain or snow. Ventilation openings shall have a least dimension of 1/16 inch T.6 mm) minimum and T/4 inch <br />(6A mm) maximum. Ventilation openings having a least dimension larger than 1/4 inch (6.4 mm) shall be provided <br />with corrosion -resistant wire cloth screening, hardware cloth or similar material with openings having a least dimension of <br />1116 inch (1.6 mm) minimum and 1/4 inch (6.4 mm) maximum. Openings in roof framing members shall conform to <br />the requirements of Section R802.7. Required ventilation openings shall open directly to the outside air. <br />R806.2 Minimum vent area. The minimum net free ventilating area shall be 1/150 of the area of the vented space. <br />Exception: The minimum net free ventilation area shall be <br />1/300 of the vented space provided one or more of the following conditions are met: <br />1. In Climate Zones 6, 7 and 8, a Class I or II vaporretarder Is installed on the warm -in -winter side of <br />the ceiling. <br />2. Not less than 40 percent and not more than 50 percent of the required ventilating area is provided by <br />ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not <br />more than 3 feet (914 mm) below the ridge or highest point of the space measured vertically, with the <br />balance of the required ventilation provided by eave or cornice vents. Where the location of wall or roof <br />framing members conflicts with the installation of upper ventilators, installation more than 3 feet (914 <br />mm) below the ridge or highest point of the space shall be permitted. <br />R806.3 Vent and insulation clearance. Where eave or cornice vents are installed, insulation shall not block the free <br />flow of air. Not less than a 1-inch (25 mm) space shall be provided between the insulation and the roof sheathing and at the <br />location of the vent. <br />R806.4 Installation and weather protection. Ventilators shall be installed in accordance with manufacturer's instructions. <br />Installation of ventilators in roofsystems shall be in accordance with the requirements of Section R903. Installation <br />of ventilators in wall systems shall be in accordance with the requirements of Section R703.1. <br />DETAIL B <br />MUDROOM TRUSS <br />T 6" <br />IRC R906.3 An insulation baffle with a minimum of a 1" air space installed between the insulation and the <br />underside of the roof sheeting at the location of the vent shall be provided to maintain air flow. <br />IRC R807.1 Attic access must have minimum size of 22" x 30" with 30" unobstructed headroom and be <br />readily accessible. <br />IRC R905.2 Asphalt shingles require underlayment (151b felt paper or equivalent) and a minimum 4:12 <br />pitch on solid sheathed decks. Asphalt shingles may be installed on slopes as low as 2:12, if <br />provided double underlayment. Asphalt shingles shall be self sealing or be interlocking. <br />IRC R905.10.4 Metal Roofing shall be attached with Galvanized or Stainless Steel fasteners; or per <br />manufacturers' specifications. <br />IRC R907.3 New composition roofing may be installed over existing roofing if there is 2 or less layers of <br />existing composition roofing; or if the existing roofing has not deteriorated so it cannot support the <br />new roofing. <br />West Coast Structural Engineering Inc. <br />QrAn .R miah-n P—ku tt177 Rlnin WA QR7Rn <br />STRUCTURAL REVIEW <br />THIS DRAWING HAS BEEN <br />REVIEWED FOR STRUCTURAL <br />REQUIREMENTS ONLY PER <br />THE ATTACHED <br />CALCULATIONS. <br />PROJECT NO: W4700 <br />ROOF FRAMING PLAN - REVISED 9121 <br />Olson Addition <br />2007 Cedar Street <br />PLAN:A20-ND <br />Everett, WA <br />Key Design, Inc. <br />Key Design, Inc. <br />SCALE: 1 /4r' = 1 r Or' <br />—• <br />Homes of Quality <br />Design and Construction <br />7433 76th Dr NE <br />Marysville, WA 98270 <br />6 10 <br />(425) 350-1702 <br />of <br />