S T R U (_"`-'T'u' R A L N 0 T E S <br />Kowa- 4 1 <br />I. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, <br />SPECIFICATIONS, AND THE 2018 INTERNATIONAL BUILDING CODE. <br />2. DESIGN LOADING CRITERIA: <br />RESIDENTIAL - ONE AND TWO-FAMILY( DWELLINGS <br />FLOOR LIVE LOAD . . . . . . . . . . . . . . . . . . . . 40 PSF <br />ROOF <br />ROOF DEAD LOAD . . . . . . . . . . . . . . . . . . . . . 15 PSF <br />ROOF LIVE LOAD . . . . . . . . . . . . . . . . . . 25 PSF <br />DECK LIVE LOAD . . . . . . . . . . . . . . . . . . . . . . 60 PSF <br />DEFLECTION CRITERIA <br />LIVE LOAD DEFLECTION . . . . . . . . . . . . . . . . . . L/360 <br />TOTAL LOAD DEFLECTION . . . . . . . . . . . . . . . . . . . L/240 <br />ENVIRONMENTAL LOADS <br />SNOW . . . . . . . . . . 25 PSF <br />WIND . . Kzt= 1.88, GCpI®0.18, 98 MPH, RISK CATEGORY 11, EXPOSURE "B" <br />EARTHQUAKE . ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE <br />LATERAL SYSTEM: LIGHT FRAMED SHEAR WALLS <br />SITE CLASS=D, Ss=1.28 Sds=1.0, S1 =.45, SDI a.56, Csm0.154 <br />SDC D, Iem1.0, R®6.5 <br />3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR <br />BIDDING AND CONSTRUCTION. ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. <br />ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE SPECIFICATION, THESE GENERAL NOTES <br />AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH <br />DISCREPANCY IN WRITING. ANY WORK DONE BY THE GENERAL CONTRACTOR AFTER DISCOVERY OF <br />SUCH DISCREPANCY SHALL BE DONE AT THE GENERAL CONTRACTOR'S RISK. <br />4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS <br />SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL DIMENSION CONTROL IS <br />DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING SECTION, AND PLANS. <br />5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, <br />TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE <br />STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT <br />RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS <br />RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO <br />DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES <br />TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. <br />6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL <br />COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE <br />PLANS. CONFORM TO ASC€ 37-14 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION". <br />7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND <br />STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. <br />8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE <br />NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR <br />DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE <br />ARCHITECT AND THE STRUCTURAL ENGINEER. ALL TYPICAL NOTES AND DETAILS SHOWN ON <br />DRAWINGS SHALL APPLY, UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE <br />INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. <br />WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CHOOSE <br />THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED OR REQUEST ADDITIONAL INFORMATION. <br />10.FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURES ARE ASSUMED <br />BASED ON SOIL CONDITIONS CONSISTING OF SAND, SILTY SAND, OR CLAYEY SAND AND THEREFORE <br />MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE BUILDING OFFICIAL. IF <br />SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR <br />POSSIBLE FOUNDATION REDESIGN. <br />FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED <br />GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS <br />ABOVE. <br />BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR <br />SUBSURFACE DRAINAGE. <br />ALLOWABLE SOIL PRESSURE . . . . . . . . . . . . . . . . . . . . . 1500 PSF <br />LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) . . . . . . 55 PCF/35 PCF <br />ALLOWABLE PASSIVE EARTH PRESSURE (FS OF 1.5 INCLUDED). . . . . . 300 PCF <br />COEFFICIENT OF FRICTION (FS OF 1.5 INCLUDED . . . . . . . . 0.3 <br />0 <br />11.PIN PILES SHOWN ON THE PLAN SHALL BE 2" DIAMETER SCHEDULE 80. THE MAXIMUM CAPACITY <br />OF 2" PILES SHALL BE 3 TONS. ALL PILES SHALL BE DRIVEN TO REFUSAL AS A MINIMUM, <br />PILE REFUSAL SHALL BE DEFINED AS 1 INCH OF PENETRATION IN 60 SECONDS DURING <br />CONTINUOUS DRIVING OF A 90 LB JACK HAMMER UNDER THE FULL WEIGHT AND EFFORT OF THE <br />OPERATOR. THE MAXIMUM PILE ECCENTRICITY SHALL BE 2 INCHES. GEOTECHNICAL SPECIAL <br />INSPECTION SHALL BE REQUIRED TO VERIFY THE ABOVE CRITERIA. <br />qlgwovyAvm <br />12.DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY <br />DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED <br />AND iN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE <br />ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING <br />(INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. <br />13.CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO <br />COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS <br />ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE CONTRACTOR SHALL NOTIFY THE <br />ARCHITECT AND STRUCTURAL ENGINEER IF EXISTING CONDITIONS DETERMINED DURING WORK VARY <br />FROM THE EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS. <br />14.EXISTING REINFORCING SHALL BE SAVED WHERE AND AS NOTED ON THE PLANS. SAW CUTTING, <br />WHERE USED, SHALL NOT CUT EXISTING REINFORCING TO BE SAVED. <br />A. WHERE NEW REINFORCING TERMINATES AT EXISTING CONCRETE, DRILL AND EPDXY DOWELS <br />MATCHING THE NEW REINFORCING INTO THE EXISTING CONCRETE WITH 5" EMBED, UNLESS <br />OTHERWISE NOTED ON PLANS. <br />15.CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH ACI <br />301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF Vc = <br />3,000 PSI AND OF <br />AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR <br />REQUIRED CONCRETE <br />STRENGTH IS BASED ON THE i REQUIREMENTS SECTION 1904 OF THE IBC. DESIGN <br />17.DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE <br />WITH ACI 315-99 AND 318®-11. LAP ALL CONTINUOUS REINFORCEMENT #5 AND SMALLER 40 BAR <br />DIAMETERS OR 2'---0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING <br />INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. <br />18.CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: <br />UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH . . 3" <br />FORMED SURFACES EXPOSED TO EARTH OR WEATHER (5 BARS OR SMALLER). . 1-1/2" <br />SLABS AND WALLS (INT. FACE). . . GREATER OF BAR DIAMETER PLUS 1/8 OR 3/4" <br />19.CONCRETE WALL REINFORCING --PROVIDE THE FOLLOWING UNLESS DETAILED OTHERWISE: <br />6" AND 8" WALLS #4 0 12 HORIZ. #4 @ 16 VERTICAL 1 CURTAIN <br />20.CAST-IN-PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND <br />DIMENSIONS OF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE ARCHITECTURAL <br />DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND <br />OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. <br />21.NONg-SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED <br />AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. <br />GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3000 <br />PSI MINIMUM). <br />22.EXPANSION BOLTS INTO CONCRETE SHALL B ■WEDGE <br />MANUFACTURED BY THE SIMPSON.CONFORMANCE <br />REPORTTO ICC-ES B <br />23.EPDXY-GROUTED ITEMS <br />(THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS <br />SHALL Br Ri i <br />BE <br />INSTALL IN STRICT ACCORDANCE WITH IAMPO REPORT NO. ER-0281. MINIMUM BASE MATERIAL <br />TEMPERATURE IS 14 <br />B - _ R. O NOTED. <br />wETE SCREW _iR.:__ i CONCRETE SHALL r:_ "TITEN HD" HEAVY DUTY SCREW ANCHOR <br />COMPANY,AS MANUFACTURED BY THE SIMPSON STRONG -TIE <br />WITH ICC-ES REPORT NO. ESR-2713. <br />STEEL <br />25.WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, FY = 50 KSI. OTHER ROLLED SHAPES <br />INCLUDING PLATES, SHALL CONFORM TO ASTM A36, FY = 36 KSI. CONNECTION BOLTS SHALL <br />CONFORM TO ASTM A307. <br />26.ARCH ITECTU RALLY EXPOSED STRUCTURAL STEEL SHALL CONFORMi; 10 OF <br />STANDARDCODE OF PRACTICE <br />j BUILDINGS AND <br />WOOD <br />27.FRAMING LUMBER SHALL BE S-DRY, KD, OR MC-19, AND GRADED AND MARKED IN CONFORMANCE <br />WITH WCLIB STANDARD, GRADING RULES FOR WEST COAST LUMBER NO. 17, OR WWPA STANDARD, <br />WESTERN LUMBER GRADING RULES 2011. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: <br />JOISTS (2X & 3X MEMBERS) <br />AND BEAMS <br />(4X MEMBERS) <br />BEAMS (INCL. 6X AND LARGER) <br />POSTS (4X MEMBERS) <br />(6X AND LARGER) <br />STUDS, PLATES & MISC. FRAMING: <br />HEM -FIR NO. 2 <br />MINIMUM BASE VALUE, Fb = <br />850 PSI <br />DOUGLAS FIR -LARCH NO. 1 <br />MINIMUM BASE VALUE, Fb - <br />1000 PSI <br />DOUGLAS FIR --LARCH NO. 1 <br />MINIMUM BASE VALUE, Fb <br />1350 PSI <br />DOUGLAS FIR ---LARCH NO. 2 <br />MINIMUM BASE VALUE, Fc <br />1350 PSI <br />DOUGLAS FIR -LARCH NO. 1 <br />MINIMUM BASE VALUE, Fc <br />1000 PSI <br />DOUGLAS-FIR-LARCH OR HEM -FIR <br />NO. 2 <br />IF LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE <br />STANDARDS. EACH MEMBERSHALL <br />BE ACCOMPANIED BY AN OR APA-EWSALL BEAMS SHALL <br />BE DOUGLAS FIR COMBINATIONb 0 <br />29.MANUFACTURED LUMBER, LVL, SHOWN ON PLAN ARE BASED PRODUCTS MANUFACTURED BY THE <br />WEYERHAEUSER CORPORATION IN ACCORDANCEREPORT MEMBERS SHALL <br />HAVE THE FOLLOWING MINIMUM PROPERTIES: <br />LVL (2.OE) Fb = 2600 PSI, E = 2000 KSI, Fv = 285 PSI <br />30.PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL 11, EXTERIOR GLUE <br />IN CONFORMANCE WITH DOC PS 1 OR PS 2. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, <br />EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. <br />FLOOR SHEATHING SHALL BE 3/4" (NOMINAL) WITH SPAN RATING 48/24. <br />WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0. <br />AL ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH <br />SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF <br />SHEATHING. <br />REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. <br />31.ALL WOOD IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE -TREATED WITH AN APPROVED <br />PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED <br />BETWEEN UNTREATED WOOD AND CONCRETE. <br />32.PRESERVATIVE TREATED WOOD SHALL BE TREATED PER AWPA STANDARD U1 TO THE USE <br />APPLICATION. TREATED W <br />CATEGORY EQUAL TO OR HIGHER THAN THE INTENDEDWOOD FOR ABOVE <br />GROUND USE SHALL BE TREATED TO AWPA UC3B. WOOD IN CONTINUOUS CONTACT WITH FRESH <br />WATER OR SOIL SHALL BE TREATED TO AWPA UC4A. WOOD FOR USE 1N PERMANENT FOUNDATIONS <br />SHALL BE TREATED TO AWPA UC4B. <br />33.FASTENERS AND TIMBER CONNECTORS USED WITH TREATED WOOD SHALL HAVE CORROSION <br />RESISTANCE AS INDICATED IN THE FOLLOWING TABLE, UNLESS OTHERWISE NOTED. <br />WOOD TREATMENT CONDITION PROTECTION <br />HAS NO AMMONIA CARRIER INTERIOR DRY G90 GALVANIZED <br />CONTAINS AMMONIA CARRIER INTERIOR DRY G185 OR A185 HOT DIPPED OR <br />CONTINUOUS HOT --GALVANIZED <br />PER ASTM A653 <br />CONTAINS AMMONIA CARRIER INTERIOR WET TYPE 304 OR 316 STAINLESS <br />CONTAINS AMMONIA CARRIER EXTERIOR 'TYPE 304 OR 316 STAINLESS <br />AZCA ANY TYPE 304 OR 316 STAINLESS <br />34.TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY <br />SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-C-a2019 AND SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS. ALL <br />BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "HU/HUCQ" SERIES JOIST HANGERS, UNO. <br />ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM)AS MEMBERS <br />CONNECTED. <br />Ngwaffilmmium <br />SIZE LENGTH DIAMETER <br />8d 2-1/2" 0.131 " <br />16d 3-1/4" 0.131" <br />B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE <br />HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG <br />BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION <br />WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER, LEAD HOLES ARE <br />NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. <br />36.NOTCHES AND HOLES IN WOOD FRAMING: <br />A. NOTCHES ON THE ENDS OF SOLID SAWN JOISTS AND RAFTERS SHALL NOT EXCEED <br />ONE-FOURTH <br />THE JOIST DEPTH. NOTCHES IN THE TOP OR BOTTOM OF SOLID SAWN JOISTS SHALL NOT <br />EXCEED ONE -SIXTH THE DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE THIRD OF THE <br />SPAN. HOLES BORED IN SOLID SAWN JOISTS AND RAFTERS SHALL NOT BE WITHIN 2 INCHES OF <br />THE TOP OR BOTTOM OF THE JOIST, AND THE DIAMETER OF ANY SUCH HOLE SHALL NOT <br />EXCEED ONE-THIRD THE DEPTH OF THE JOIST. <br />B. IN EXTERIOR WALLS AND BEARING PARTITIONS, ANY WOOD STUD IS PERMITTED TO BE CUT OR <br />NOTCHED TO A DEPTH NOT EXCEEDING 25 PERCENT OF ITS WIDTH. A HOLE NOT GREATER IN <br />DIAMETER THAN 40 PERCENT OF THE STUD WIDTH 1S PERMITTED TO BE BORED IN ANY WOOD <br />STUD. IN NO CASE SHALL THE EDGE OF THE BORED HOLE BE NEARER THAN 5/8 INCH TO THE <br />EDGE OF THE STUD. BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD <br />AS A CUT OR NOTCH. <br />C. NOTCHES AND HOLES IN MANUFACTURED LUMBER AND PREFABRICATED PLYWOOD WEB JOISTS <br />SHALL BE PER THE MANUFACTURERS RECOMMENDATIONS UNLESS OTHERWISE NOTED. <br />37.WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: <br />A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM <br />STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER CONSTRUCTION MANUAL" <br />AND THE AF&PA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM <br />NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO IBC TABLE 2304.10.1. COORDINATE <br />THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. <br />B. WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS <br />SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END <br />OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OIL HEADER BEARING <br />LOCATIONS, TWO 2x8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE <br />NOTED. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO <br />SUPPORTS BELOW. <br />ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP <br />PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM <br />PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d 0 12" O.C. AND LAP <br />MINIMUM X-O" AT JOINTS AND PROVIDE EIGHT 16d NAILS 0 4" O.C. EACH SIDE JOINT. <br />ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW <br />WITH TWO ROWS OF 16d NAILS @ 12" ON -CENTER, OR ATTACHED TO CONCRETE BELOW <br />WITH 5/8" DIAMETER ANCHOR BOLTS ® 4'-0" ON -CENTER EMBEDDED 7" MINIMUM, UNLESS <br />INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH <br />OTHER WITH TWO ROWS OF 16d @12" ON -CENTER. UNLESS INDICATED <br />OTHERWISE, 1/2" (NOMINAL)APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO <br />ALL EXTERIOR SURFACES WITH 8d NAILS @ 6" ON -CENTER AT PANEL EDGES AND TOP AND <br />BOTTOM PLATES (BLOCK UN -SUPPORTED EDGES)AND TO ALL INTERMEDIATE STUDS AND BLOCKING <br />WITH 8d NAILS 0 12" ON -CENTER ALLOW 1/8" SPACING AT ALL PANEL EDGES AND PANEL <br />ENDS. <br />SUPPORTSC. FLOOR FRAMING. PROVIDE SOLID BLOCKING AT ALL BEARING TOE -NAIL JOISTS TO <br />NAILS. HEADERS . BEAMS WITH <br />NOTEDSIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI JOIST <br />BEAMS TOGETHER WITH TWO ROWS 16d @ 12" ON -CENTER. <br />UNLESS OTHERWISE ON THE PLANS, PLYWOOD FLOOR SHEATHING SHALL BE LAID UP WITP <br />GRAIN PERPENDICULAR TO SUPPORTS AND NAILED AT 6" ON -CENTER WITH 8d NAILS TO FRAMED <br />PANEL EDGES, AND @ 12" ON -CENTER TO INTERMEDIATE SUPPORTS. FLOOR SHEATHING <br />EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID <br />BLOCKING. ALLOW 1/8" SPACING AT _ PANEL EDGESO ROOF <br />TOENAIL BLOCKING O SUPPORTS WITH 16d @ UNO. <br />QUALITY ASSURANCE <br />1. SPECIAL INSPECTIONS SHALL BE PROVIDED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS <br />AND SECTIONS 110 AND 1705 OF THE INTERNATIONAL BUILDING CODE BY A QUALIFIED TESTING <br />AGENCY DESIGNATED BY ATHE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE <br />ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH <br />COPIES OF ALL INSPECTION AND TEST RESULTS. SPECIAL INSPECTION OF THE FOLLOWING <br />TYPES OF CONSTRUCTION IS REQUIRED UNLESS NOTED OTHERWISE. <br />DRIVEN PIPE PILE CONSTRUCTION CONTINUOUS <br />POST INSTALLED CONCRETE RODS AND ANCHORS PERIODIC <br />rERIODIC INSPECTION: INSPECTION SHALL BE PERFORMED AT INTERVALS NECESSARY TO <br />CONFIRM THAT WORK REQUIRING ,L INSPECTIOREQUIREMENTS. <br />CONTINUOUS INSPECTION:O D OBSERVE <br />INISPECTIONTIMES THAT WORK IS PERFORMED. <br />e <br />� 31728 <br />��O 1� <br />E <br />c� 0 <br />U) 00 <br />p N U <br />O O7 <br />0 < Lc) <br />_3i r i P,-) 0 <br />n 0- i1 <br />z v C,6 0 <br />o <br />0 <br />� N N <br />(!1 Ct -3: <br />O <br />00 <br />CIO <br />CM <br />cd <br />Q <br />z <br />0 <br />w <br />Li <br />� <br />CD <br />L <br />z <br />cn s <br />_j s <br />cDc� <br />wQ <br />oQ <br />3-: <br />z <br />z o <br />w u <br />� Q <br />I <br />V <br />0 <br />cn <br />��gQaq <br />DRAWN BY: SAC, ME <br />CHECKED BY: XXX <br />PLOT DATE: 16 NOV 2021 1 FILE NAME: MILES <br />no <br />