Laserfiche WebLink
r E <br />CJ O <br />ENERGY <br />NOTES <br />ENERGY <br />NOTES (CONT.)T) <br />- N� <br />or <br />Ln = <br />��� <br />U <br />0-) �? <br />CODE COMPLIANCE: <br />2018 WASHINGTON STATE ENERGY CODE INCLUDING CITY OF EVERE-hT AMENDMENTS. <br />INSULATION <br />7- <br />0 <br />SECTION R402.1.1 PRESCRIPTIVE - INSULATION AND FENESTRATION REQUIREMENTS BY <br />INSTALLATION <br />CONFORM TO TABLE R402.4.1.1 OF THE WASHINGTON STATE ENERGY CODE <br />N N <br />COMPONENT. <br />0) <br />cry 0 ­�--- 3: <br />FIREPLACES: <br />CONFORM TO SECTION R402.4.2 OF THE WASHINGTON STATE ENERGY CODE. <br />CLIMATIC ZONE. <br />4C KING COUNTY <br />NEW WOOD -BURNING FIREPLACES SHALL HAVE TIGHT -FITTING FLUE DAMPERS AND <br />DESIGN CRITERIA: <br />THE INTERIOR DESIGN TEMPERATURES USED FOR HEATING AND COOLING LOAD <br />OUTDOOR COMBUSTION AIR. <br />CALCULATIONS SHALL BE A MAXIMUN OF 72 DEG F FOR HEATING AND A MINIMUM OF <br />75 DEG FOR COOLING. R302.1 <br />COMPLY WITH SECTION 1004 OF THE SEATTLE RESIDENTIAL CODE AND SHALL BE UL-127 <br />LISTED, LABELED AND TESTED. INSTALL ACCORDING TO MANUFACTURERS REQUIREMENTS. <br />THE HEATING OR COOLING OUTDOOR DESIGN TEMPERATURES SHALL BE PER APPENDIX C <br />OF THE 2014 WASHINGTON STATE ENERGY CODE. R302.2 <br />PROVIDE WITH OUTSIDE AIR SOURCE. DUCT SIZE MINIMUM SIX SQUARE INCHES. FITTED <br />WITH A READILY OPERABLE DAMPER. <br />0 <br />EVERETT OUTDOOR DESIGN TEMPERATURE: HEATING 24 DEG F. COOLING 83 DEG F. <br />kli <br />VENTILATION: <br />ATTICS WITH LOOSE FILL: BAFFLE VENT OPENINGS TO DEFLECT AIR ABOVE INSULATION <br />REQUIRED - PEESCRIPTIVE <br />FENESTRATION U-FACTOR <br />.30 <br />SKYLIGHT U-FACTOR <br />.50 <br />CEILING R-VALUE (ATTIC) <br />49 <br />CEILING R-VALUE (JOIST VAULTED) <br />38 <br />CEILING R-VALUE (SINGLE RAFTER) <br />38 <br />WOOD FRAME WALL R-VALUE <br />21 <br />FLOOR R VALUE <br />30 <br />BELOW GRADE CAVITY WALL R-V <br />21 <br />ko <br />SLAB R-VALUE (2 FT DEPTH) <br />PROPOSED SURFACE. <br />.28 <br />.50 ENCLOSED JOIST OR RAFTER SPACES: PROVIDE MINIMUM OF ONE INCH CLEAR VENTED AIR <br />49 SPACE ABOVE INSULATION. TAPER OR COMPRESS INSULATION AT PERIMETER TO INSURE 0 <br />NA <br />PROPER VENTILATION. <br />NA SYSTEMS CONFORM TO R403.6 OF THE WASHINGTON STATE ENERGY CODE, ccoo <br />21 HEATING & COOLING <br />30 HEATING & COOLING EQUIPMENT SHALL BE SIZED IN ACCORDANCE WITH ACCA MAUNUAL <br />NA "S" BASED ON BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL " J" <br />10 OR OTHER APPROVED HEATING & COOLING CALCULATION METHODOLOGIES. <br />