Laserfiche WebLink
TYP EXISTING ROOF ASSE <br />4 <br />-EXISTING ROOFING MATERIAL <br />-EXISTING ROOFING PAPER <br />-EXISTING SHEATHING <br />-EXISTING FRAMING <br />-EXISTING AIR SPACE OR RAFFLE FOR 2" MIN AiR SPACE <br />-EXISTING INSULATION OR FiLL R-49 DATT INSULATION Cad EXPOSED ATTIC AREAS <br />-EXISTING GWD OR NEW 5/5" GWD 9 AREAS OF ALTERATION <br />-PVA PRIMER <br />OVERFRAME Cad EXISTING ROOF PER STRUCTURAL <br />OUTDOORTYP LIVING F ASSEMBLY <br />-30 YEAR ARCHITECTURAL ASPHALT COMPOSITE ROOF TO MATCH EXISTING <br />-HENRY DLUESKIN RF200 (OR DETTER) DRAINAGE PLANE INSTALL SHINGLE FASHION <br />-CDX PLYWOOD SHEATHING PER STRUCTURAL <br />-FRAMING PER STRUCTURAL <br />-1/2" T&G SOFFIT <br />TYP EXISTING EXTERIOR ALL LY <br />-EXISTING SiDiNG <br />-EXISTING DUILDING PAPER OR HENRY DLUESKIN VP100 <br />AREA OF ALTERATION <br />-EXISTING PLYWOOD SHEATHiNG OR PER STRUCTURAL <br />-EXISTING FRAMING OR PER STRUCTURAL <br />-EXISTING INSULATION OR R-15 H.D. DATT INSULATION <br />INSTALLED AT ALL EXPOSED 2X4 STUD DAYS OR R-21 DATT <br />INSULATION IN EXPOSED 2X6 STUD DAYS <br />-EXISTING FINISH WALL OR 1/2"GWD <br />-PVA PRIMER <br />TYP EXISTING AI FLOOR ASSEMBLY <br />-FiNiSH FLOOR PER PLAN <br />-EXISTING SHEATHING <br />-EXISTING FRAMING (VERIFY DIMENSION) <br />-EXISTING INSULATION OR INSTALL R-30 DATT INSULATION 9 <br />EXPOSED AREAS OVER UNCONDITIONED SPACES <br />TYP NEW DECK ASSEMBLY <br />-DECKING WITH 1/8" GAPS <br />-P.T. FRAMING PER STRUCTURAL <br />INSTALL METAL DOOR PAN & FLASHING, TYP <br />INSTALL WATERPROOF MEMDRANE UNDER LEDGER <br />AND COUNTERFLASH OVER TOP, INSTALL METAL <br />FLASHING W1 DRIP EDGE OVER FLASHING OVER <br />LEDGER, TYP <br />EXISTING SiDiNG TO REMAIN; PATCH TO MATCH 9 <br />AREAS OF ALTERATION <br />EXISTING WALL OR PER STRUCTURAL 9 <br />LOWER FLOOR WALL, TYP <br />EXISTING FOUNDATION DRAIN, <br />VERIFY <br />EXISTING CONCRETE FOUNDATION <br />AND FOOTING TO REMAIN OR PER <br />STRUCTURAL <br />EXISTING VAPOR DARRiER. OR INSTALL 10MIL <br />POLYETHELENE VAPOR DARRIER AT EXPOSED <br />CRAWLSPACE TYP; LAP EDGES 12" MiN, RUN <br />UP WALLS 12" MiN. <br />WALL�, � ` 1 ¢ I 8 <br />W k <br />DECKING Cad STAiR RiSER AND <br />��� <br />TREAD, TYP (1/8" GAP) <br />TYP NEW EXTERIOR RAILING <br />\ <br />— — — — — <br />— <br />ASSEMDLY PER DETAIL <br />/✓ <br />11/2" 0 METAL TOP RAIL LOP c- <br />� <br />( <br />i REFER TO STRUCTURAL FOR <br />j <br />ALL FRAMING <br />I <br />I <br />TEMPERED GLASS <br />I <br />I <br />PANEL PER <br />I - — o — o — `_' ®� <br />I <br />I <br />MANUFACTURER <br />I <br />—TYP <br />DRiP-THRU PECK <br />G <br />TYP NEW DECK ASSEMDLY, <br />ASSEMDLY <br />PER DETAIL 1/A4.0 <br />I <br />i <br />METAL FLASHING AND DRiP <br />I <br />----1"x11/2" <br />METAL DOTTOM <br />I <br />I EDGE <br />I <br />i <br />RAiL <br />I <br />I <br />! <br />I <br />STEEL PLATE, DOLT TO <br />1 <br />DEAM PER �`� ®� <br />®�f <br />DECK APRON WALL ASSEMDLY <br />I <br />R <br />DECK PER STRUCTURAL <br />STRUCTURAL <br />-STONE VENEER TO DE <br />; <br />I <br />POST PER <br />SELECTED <br />METAL DRiP EDGE, TYP <br />STRUCTURAL <br />( <br />-HENRY DLUESKIN VP100 OR <br />I <br />I <br />APPROVED DUILDING PAPER <br />I <br />CONCRETE PLINTH <br />-CDX PLYWOOD PER <br />I <br />AND FOUNDATION <br />STRUCTURAL <br />I <br />PER STRUCTURAL <br />cp <br />-P.T. FRAMING PER STRUCTURAL <br />k <br />I <br />DECK APRON WALL <br />FINISH GRADE <br />----MiN 1/2" REVEAL FOR DRAINAGE <br />GYP EXTERIOR RAILING <br />*CONFIRM METAL POWDER COATING COLOR <br />SCALE:1/2" = 1'-C" <br />FASTEN SKYLIGHT TO CURD <br />WiTH FINISH SCREWS <br />UNDEKLAYMENT NOTE 1 & 3 <br />SADDLE FLASHING <br />i <br />HEAD FLASHING PLACED <br />13ETWEEN UNDERLAYMENT <br />HEADER PER STRUCT. <br />SKYLIGHT PER DETAIL 4/A4.0 <br />ly <br />TYP OUTDOOR LiViNG <br />TYP OUTDOOR LiViNG ROOF ASSEMDLY <br />I <br />I ROOF ASSEMDLY <br />I <br />PER DETAIL <br />`� <br />i —METAL DRiP EDGE, TYP <br />�\ <br />I <br />\ <br />I <br />K-STYLE METAL GUTTER <br />TYP EAVE ASSEMDLY& <br />PER DETAIL <br />I <br />I <br />DOWNSPOUT, TYP <br />I <br />METAL EDGE FLASHING, TYP <br />j <br />5/4X_ WD FASCIA; PAINTED TO MATCH <br />EXISTING <br />f EXIEXI TIN G PROFILE <br />K STYLE METAL GUTTER &DOWNSPOUT, TYP <br />-------® ®®®®®®®—®� <br />SOFFIT <br />5/4X_ WD FASCIA, TYP TO MATCH <br />2" CONTINUOUS FLUSH VENT <br />EXISTING PROFILE <br />W/ NON -CORROSIVE WiRE <br />2" CONTINUOUS FLUSH VENT W/ NON-CORROSIVETYP <br />EAVE ASSEMBLY <br />INSECT SCREEN, TYP <br />WiRE INSECT SCREEN, TYP <br />SCALE:1"=1'-O" <br />DEAM PER STRUCTURAL, WRAP <br />PER DETAIL <br />-- --- POST PER STRUCTURAL, WRAP PER DETAIL <br />61/2"+/- <br />POST PER STRUCTURAL <br />_ <br />DLOCKiNG TO CONCEAL <br />% <br />I <br />DOLTS/CONNECTORS AS NEEDED <br />MITERED CORNERS, TYP <br />\ <br />f <br />WRAP W/ 1x_ CEDAR, GLUE & NAIL; <br />PAINTED, TYP <br />TYP NEW DECK ASSEMDLY, <br />PER DETAIL <br />EX GRADE <br />3j8„ <br />„5 �� <br />5�QS <br />5. 5 //4 <br />1. UNDERLAYMENT TO DE FOLDED UP AGAINST ALL SIDES OF CURDS. <br />2. VAPOR DARRIEK SHOULD DE USED TO AVOiD MOISTURE. <br />3. WRAP CURD iN UNDERLAYMENT. <br />P �A. <br />� a H DETAIL <br />11/2" =1'-0° <br />�_ WALL SECTION <br />SCALE: 1" = T-o" <br />Emp <br />CURD -MOUNTED <br />FIXED SKYLIGHT <br />BIRD <br />L FLASHING PER <br />,NUF.'S REQ'S <br />PERLAYMENT <br />TE1&3 <br />YEAR ASPHALT <br />AP. ROOFING <br />,TERIAL <br />" T&G SOFFIT <br />TYP. ROOF ASSEMDLY <br />ARCH ITEGT U R E <br />D E S I G N <br />23020 EDMONDS WAY, #113 <br />EDMONDS, WA 98020 <br />P. 206 ® 542 ® 3 7 34 <br />www.h2darchitects.com <br />DATE: 5//2021 <br />PERMIT SST <br />SCALE:1/" = 1'-0" <br />