GENERAL STRUCTURAL NOTES <br />(THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS.) <br />GENERALA. <br />C. FOUNDATION <br />E. CARPENTRY <br />1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE <br />1. FOUNDATION EXCAVATION, BACKFILL AND COMPACTION SHALL CONFORM TO SPECIFICATION <br />1. GLUED LAMINATED MEMBERS SHALL DE FABRICATED IN CONFORMANCE WITH ANSI STANDARD <br />8. WOOD TRUSSES <br />DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION, AS <br />REQUIREMENTS. THIS CONSTRUCTION WORK, INCLUDING DRAINAGE, SHORING AND SUCH OTHER <br />A190.1. EACH MEMBER SHALL BEAR AN RITC OR APA EWS IDENTIFICATION MARK AND SHALL BE <br />TRUSSES ARE TO BE METAL PLATED CONNECTED WOOD TRUSSES FABRICATED IN ACCORDANCE <br />AMENDED BY LOCAL JURISDICTION. <br />RELATED WORK AS REQUIRED, SHALL BE CONDUCTED BY THE CONTRACTOR UNDER THE <br />ACCOMPANIED BY AN AITC OR APA EWS CERTIFICATE OF CONFORMANCE. ALL SIMPLE SPAN BEAMS <br />WITH THE IBC. TRUSS FABRICATOR TO PROVIDE ALL REQUIRED BRIDGING AND BLOCKING, BOTH <br />OBSERVATION AND DIRECTION OF THE GEOTECHNICAL ENGINEER. <br />SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb = 2,400 PSI, Fv ®240 PSI. ALL CANTILEVERED <br />FOR ERECTION AND PERMANENT LOADING. SHOP DRAWINGS STAMPED BY A WASHINGTON STATE <br />2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS <br />BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb o 2400 PSI, Fv G 265 PSI. CAMBER ALL <br />LICENSED PROFESSIONAL ENGINEER SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL <br />FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS <br />2. FOOTINGS SHALL BEAR ON SOLD UNDISTURBED EARTH (CONTROLLED, COMPASSED <br />GLULAM BEAMS TO 2,000 RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS. <br />PRIOR TO FABRICATION. DESIGN CRITERIA SHALL MEET OF EXCEED THE FOLLOWING: <br />FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />STRUCTURAL FILL OR BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. MATERIAL <br />CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF <br />DOOR AND WINDOW OPENINGS. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF <br />TO BE COMPACTED TO 95% MINIMUM OF MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. <br />2. FRAMING LUMBER SHALL BE GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD <br />m ROOF TRUSSES TOP CHORD = 25 PSF LIVE LORD, 10 PSF DEAD LOAD, <br />MISCELLANEOUS MECHANICAL OPENINGS. <br />GRADING RULES FOR WEST COAST LUMBER, LATEST EDITION. FURNISH TO THE FOLLOWING <br />5 PSF WIND UPLIFT <br />3. FOOTINGS MAY BE POURED IN NEAT EXCAVATIONS PROVIDED SIZE IS INCREASED 3" AT EACH <br />MINIMUM STANDARDS: <br />BOTTOM CHORD = 10 PSF LIVE LOAD, 5 PSF DEAD LOAD <br />3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, <br />INTERFACE WITH SOIL. <br />TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. STRUCTURAL <br />(BOTTOM CHORD LIVE LOAD DOES NOT ACT CONCURRENTLY <br />DESIGN OF THE BUILDING IS BASED ON RESISTANCE TO DEAD LOADS, CODE SPECIFIED LATERAL <br />MEMBER SIZE SPECIES MIN. BASIC <br />WITH THE ROOF LIVE LOAD) <br />LOADS, AND MAXIMUM EXPECTED SERVICE LOADS. NO CONSIDERATION HAS BEEN GIVEN TO <br />4. ALL FOOTING EXCAVATIONS SHALL BE HAND CLEANED PRIOR TO PLACING CONCRETE. <br />GRADE DESIGN STRESS <br />TOTAL LOAD = 40 PSF <br />LOADS WHICH WILL BE INDUCED BY ERECTION PROCEDURES. THE CONTRACTOR SHALL VERIFY, TO <br />- DEFLECTION LIMIT TOTAL LOAD L/240, LIVE LOAD L/360 <br />THE SATISFACTION OF HIMSELF AND THE OWNER, THE ABILITY OF THE STRUCTURE TO RESIST ALL <br />5. ALL ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL <br />- JOISTS AND RAFTERS 2x, 3x DF#2 Fb = 875 PSI <br />- OTHER LOADS SPECIFIED ON DRAWINGS <br />ERECTION LOADS WITHOUT EXCEEDING THE ALLOWABLE STRESSES OF THE MATERIALS USED. <br />BE REMOVED. <br />4x DF#1 Fb = 1000 PSI <br />WHERE ERECTION LOADS WOULD OVERSTRESS THE STRUCTURE, THE CONTRACTOR SHALL SUBMIT <br />DESIGN DOCUMENTS FOR TEMPORARY BRACING AND STRENGTHENING, INCLUDING FABRICATION <br />- BEAMS AND STRINGERS 6x/LARGER DF#1 Fb = 1350 PSI <br />TRUSS SUPPLIERS NOTE: THE TRUSS CONFIGURATIONS, INCLUDING DEPTHS AND MEMBER SIZES, <br />AND ERECTION DRAWINGS, TO THE ARCHITECT FOR REVIEW. THESE DOCUMENTS SHALL BEAR THE <br />6. CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING, <br />- POSTS AND TIMBERS 6x/LARGER DF#1 Fb = 1000 PSI <br />SHOWN ON THE DRAWINGS INDICATE THE DESIRED TRUSS CONFIGURATIONS AND ARE TO BE <br />SEAL AND SIGNATURE OF A REGISTERED STRUCTURAL ENGINEER IN THE STATE OF WASHINGTON. <br />AND SHORING REQUIRED TO SAFELY RETAIN EXCAVATIONS. <br />- TOP AND BOTTOM PLATE @ <br />COMPLIED WITH WHERE POSSIBLE. IF A TRUSS MANUFACTURER IS UNABLE TO MEET THE LOAD <br />THE CONTRACTOR SHALL PROVIDE, INSTALL AND IF NECESSARY, REMOVE SUCH TEMPORARY <br />REQUIREMENTS SPECIFIED WITH THE TRUSS CONFIGURATION INDICATED, HE IS TO SUBMIT <br />WORK AS REQUIRED. <br />7. BACKFILL BEHIND ALL WALLS WITH WELL DRAINING, GRANULAR FILL MATERIAL, AND PROVIDE <br />- SHEAR AND BEARING WALLS 2x, 3x DF#1 Fb = 1000 PSI <br />WRITTEN NOTICE TO THAT EFFECT TO THE ARCHITECT. IT IS THE RESPONSIBILITY OF THE GENERAL <br />PERFORATED PIPE DRAINS AS DESCRIBED IN THE SOILS REPORT. BACKFILL BEHIND WALLS SHALL <br />-STUDS, PLATES & MISS. <br />CONTRACTOR AND TRUSS MANUFACTURER TO VERIFY THE WEIGHT AND LOCATIONS OF ALL <br />4. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND <br />NOT BE PLACED BEFORE THE WALL IS PROPERLY SUPPORTED BY THE FLOOR SLAB, OR <br />LIGHT FRAMING ALL SIZES DF#2 Fb = 875 PSI <br />MECHANICAL EQUIPMENT PRIOR TO SUBMITTING SHOP DRAWINGS TO THE ARCHITECT AND <br />STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES <br />TEMPORARY BRACING. ALL FOOTINGS SHALL BE CENTERED BELOW CENTERLINE OF COLUMNS OR <br />ENGINEER OF RECORD FOR REVIEW. THE DESIGN LOADS LISTED ABOVE SHALL BE APPLIED <br />SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. <br />WALLS ABOVE, UNLESS NOTED OTHERWISE. <br />ALL LUMBER WITH A LEAST DIMENSION OF 2" (NOMINAL) SHALL BE STAMPED SURFACE -DRY AND <br />SIMULTANEOUSLY. <br />SHALL HAVE A MOISTURE CONTENT WHEN SURFACED AND WHEN INSTALLED OF NOT MORE THAN 19 <br />5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS <br />D. CONCRETE <br />PERCENT. LUMBER WITH A LEAST DIMENSION OF 4" (NOMINAL) OR GREATER SHALL BE STAMPED <br />9. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: <br />ARE NOT SPECIFICALLY INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR <br />SURFACE -GREEN AND AIR-DRIED TO A MOISTURE CONTENT OF NOT MORE THAN 19 PERCENT PRIOR <br />DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE <br />1. ULTIMATE STRENGTH DESIGN PER INTERNATIONAL BUILDING CODE AND ACI 318-14 <br />TO ITS USE IN FRAMING THE STRUCTURE. <br />ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM <br />ARCHITECT AND THE STRUCTURAL ENGINEER. <br />STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE <br />6. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD <br />2. CONCRETE FOR FOOTINGS AND SLABS -ON -GRADE SHALL CONFORM TO A 28- DAY STRENGTH OF <br />3. MANUFACTURED LUMBER SHALL BE AS MANUFACTURED BY TRUS JOIST MacMILLAN OR <br />APPROVED EQUAL. REQUESTS FOR APPROVAL AS EQUAL WILL REQUIRE SUBMITTAL OF ICC-ES <br />NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE. <br />COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL <br />ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, <br />f'c = 2500 PSI, SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD, AND <br />SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. CONCRETE EXPOSED TO EARTH <br />EVALUATION REPORT EQUIVALENT TO ESR-1387 FOR PARALLEL STRAND LUMBER (PSL), LAMINATED <br />DRAWINGS. <br />HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE <br />pQ <br />OR WEATHER SHALL HAVE A 28-DAY STRENGTH OF f'c = 3000 psi. THE MINIMUM AMOUNTS OF <br />STRAND LUMBER (LSL), AND LAMINATED VENEER LUMBER (LVL). THE MINIMUM ALLOWABLE DESIGN <br />SUPPLIER. <br />CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED IF A CONCRETE DESIGN MIX IS <br />VALUES ARE AS FOLLOWS: <br />WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ <br />SUBMITTED TO THE ENGINEER AND THE BUILDING OFFICIAL FOR APPROVAL TWO WEEKS PRIOR TO <br />16"oc AT INTERIOR WALLS AND 2x6 STUDS @ 16"oc AT EXTERIOR WALLS. 2x6 STUDS @ 12"oc AT <br />7. INSPECTIONS: INSPECTIONS OF THE WOOD FRAMING THE STEEL REBAR AND WOOD FORMS FOR <br />PLACEMENT OF CONCRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF <br />- PSL (2.OE) Fb = 2,900 PSI; Fv e 290 PSI; E = 2,200,000 PSI <br />EXTERIOR BALLOON FRAMED WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF <br />CONCRETE FOOTINGS & FOUNDATIONS, AND CONCRETE SLABS ARE REQUIRED PER IBC SECTION <br />CEMENT, FINE AND COARSE AGGREGATES, WATER AND ADMIXTURES AS WELL AS THE WATER® <br />ALL WALLS AND AT EACH SIDE OF ALL OPENINGS AND UNDER THE ENDS OF ALL BEAMS. UNLESS <br />109.3. <br />CEMENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE <br />- LV _ = <br />L (2 OE) Fb = 2,600 PSI; Fv = 285 PSI, _ 2,000,000 PSI <br />NOTED OTHERWISE A (2) 2x8 HEADER SHALL BE PROVIDED OVER ALL OPENINGS IN 2x4 STUD WALLS <br />WITH ACI 318, SECTION 5.3. CONTRACTOR MAINTAINS RESPONSIBILITY FOR SPECIFIED <br />- LSL (1.55E) Fb = 2,325 PSI; Fv ® 310 PSI; E = 1,550,000 PSI <br />AND A (2) 2x10 HEADER OVER ALL OPENINGS IN 2x6 WALLS. SOLID BLOCKING FOR WOOD COLUMNS <br />8. PRE -MANUFACTURED, PRE-ENGINEERED STRUCTURAL COMPONENTS SHALL BE DESIGNED <br />PERFORMANCE OF CONCRETE PRODUCTS. ALL CONCRETE EXPOSED TO FREEZING TEMPERATURES <br />SHALL BE PROVIDED THROUGH FLOORS TO SUPPORT BELOW. PROVIDE CONTINUOUS SOLID <br />BASED ON THE CRITERIA PRESENTED IN THE CONTRACT DOCUMENTS. THE COMPONENT DESIGNER <br />WHILE CURING AND ALL CONCRETE PERMANENTLY EXPOSED TO WEATHER SHALL BE <br />4. SHEATHING A RATED PANELS " <br />H G SHALL BE APA PERFORMANCE R TE ANE-S PER APA PLYWOOD DESIGN <br />BLOCKING AT MID -HEIGHT OF ALL STUD WALLS OVER 8'IN HEIGHT. ALL STUD WALLS SHOWN ON <br />IS RESPONSIBLE FOR CODE CONFORMANCE, TEMPORARY AND PERMANENT BRACING AND ALL <br />AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO IBC SECTION 1904.2. TOTAL AIR <br />SPECIFICATION", INCLUDING APPLICABLE SUPPLEMENTS, F <br />�.�MENTS, UNLESS NOTED OTHERWISE. PLYWOOD <br />STRUCTURAL DRAWINGS SHALL HAVE THEIR LOWER PLATES ATTACHED TO WOOD FRAMING BELOW <br />NECESSARY CONNECTIONS, INCLUDING CONNECTIONS TO THE PRIMARY STRUCTURE, NOT <br />CONTENT SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF THE INTERNATIONAL BUILDING CODE.WITH <br />PANELS SHALL BE GRADE C-D AND ALSO CONFORM DOC PS-2. ALL PANELS SHALL BE <br />16d NAILS AT 12"oc STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR <br />SPECIFICALLY CALLED OUT ON THE ARCHITECTURAL OR STRUCTURAL DRAWINGS. SHOP <br />NO ADMIXTURES, OTHER THAN FOR AIR -ENTRAINMENT AS NOTED ABOVE, SHALL BE USED WITHOUT <br />IDENTIFIED AS EXPOSURE 1 UNLESS NOTED OTHERWISE. T <br />PANNELEL RATING T O BE AS FOLLOWS <br />BOLTS AT 4'-0"oc, EMBEDED 7", LINO REFER TO THE STRUCTURAL PLANS AND SHEAR WALL <br />DRAWINGS SHALL INDICATE THE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE <br />PRIOR REVIEW BY THE STRUCTURAL ENGINEER. ALL CONCRETE IN ELEVATED STRUCTURALSCHEDULE <br />UNLESS NOTED OTHERWISE: <br />FOR REQUIRED SHEATHING AND NAILING. <br />PRIMARY STRUCTURE. SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED AS NOTED <br />SLABS AND BEAMS SHALL BE POURED MONOLITHICALLY UNLESS SHOWN OTHERWISE OR <br />PREVIOUSLY. <br />APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. <br />- ROOF 19/32°' THICK, 32/16, (OR 5/8" THICK), 32/16 <br />FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS AND <br />DESIGNI T I <br />3. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 (INCLUDING <br />- WALLS 15/32" THICK, 32/16, (OR 1/2" THICK), 24/0 <br />AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE BRIDGING @ <br />8'-0"oc AND SOLID BLOCKING AT ALL BEARING POINTS. COORDINATE THE SIZE AND LOCATION OF ALL <br />SUPPLEMENT S1), GRADE 60, N = 60,000 PSI, EXCEPTIONS: ANY BARS SPECIFICALLY NOTED ON <br />-FLOORS 23/32" (OR 3/4") THICK, TONGUE & GROOVE, 48/24 <br />OPENINGS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. TOENAIL JOISTS TO BEARING <br />1. DESIGN LOADS <br />THE DRAWINGS AS GRADE 40, fy = 40,000 PSI. WELDED WIRE FABRIC: ASTM A82 AND ASTM A185, <br />SUPPORTS WITH 16d NAILS. UNLESS NOTED OTHERWISE. <br />- ROOF SNOW LOAD 25 PSF <br />SPLICE WITH AT LEAST ONE FULL MESH. PLACE AT MID -DEPTH, OR SLIGHTLY ABOVE, OF SLAB. <br />- RESIDENTIAL FLOOR LIVE LOAD 40 PSF <br />MATERIAL TO BE SUPPLIED IN FLAT SHEETS. <br />UNLESS NOTED OTHERWISE ON THE PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH <br />- BEDROOM FLOOR LIVE LOAD 30 PSF <br />GRAIN PERPENDICULAR TO SUPPORTS AND NAILED WITH 1 Od NAILS @ 6"oc TO FRAMED PANEL <br />JOIST, BEAM AND HEADER SHALL BE CONNECTED TO FLUSH MEMBER WITH THE FOLLOWING <br />- EXTERIOR BALCONY & DECK <br />EDGES AND OVER STUD WALLS SHOWN ON PLANS AND @ 12"oc (10"oc AT FLOORS) TO <br />SIMPSON SERIES HANGER, U.N.O. ON PLAN, SKEW AND SLOPE ALL CONNECTORS AS REQUIRED: <br />4. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH <br />INTERMEDIATE SUPPORTS. PROVIDE APPROVED SHEATHING EDGE CLIPS @ 16"oc AT UNBLOCKED <br />- 2x JOIST, "LUS" SERIES; DOUBLE 2x JOIST/HEADER, "HU'T'HUS" SERIES <br />LIVE LOAD 60 PSF <br />ACI 315-02. LAP ALL CONTINUOUS REINFORCEMENT PER NOTE D.5. PROVIDE CORNER BARS AT ALL <br />ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED <br />WALL INTERSECTIONS. LAP CORNER BARS PER NOTE D.5. LAP ADJACENT MATS OF WELDED WIRE <br />TONGUE -AND -GROOVE JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. TOENAIL <br />- TJI JOIST, "ITS" SERIES; DOUBLE TJI JOIST, "MIT" SERIES <br />-WIND (IBC) 110 MPH (LRFD) <br />FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. <br />BLOCKING TO SUPPORTS WITH 16d NAILS, UNLESS NOTED OTHERWISE. <br />- 4x MEMBER, "HU" SERIES; 6x MEMBER, "HWP"/"HWPH" SERIES <br />EXPOSURE B, Kzt = 1.0 <br />- 3-1/2"GLB, "FIB" SERIES; 5-1/2"GLB, "HWPH" SERIES, 6-3/4"GLB, "HGLTV" SERIES <br />- EARTHQUAKE (ASCE7) SITE CLASS D <br />5. REINFORCING STEEL LAPS AND EMBEDMENT SHALL BE AS NOTED BELOW, UNLESS NOTED <br />UNLESS NOTED OTHERWISE ON THE PLANS, WALL SHEATHING MAY BE LAID UP HORIZONTALLY OR <br />- 1-3/4"SCL, "IUS" SERIES; 3=1/2"SCL, "HB" SERIES, 5-1/4"SCL, "HWPH" SERIES, 7"SCL, "HGLTV" SERIES <br />SEISMIC USE GROUP 1 (le ® 1.0) <br />OTHERWISE, ALL HOOKS SHALL BE "STANDARD" IN ACCORDANCE WITH ACI 318. REINFORCING <br />VERTICALLY, UNSUPPORTED EDGES SHALL BE BLOCKED AND ALL EDGES SHALL BE NAILED WITH 8d <br />SEISMIC DESIGN CATEGORY D <br />SHALL NOT BE TACK WELDED: <br />@ 6"oc, NAIL WITH 8d @ 12"oc AT INTERMEDIATE SUPPORTS. NAIL SHEAR WALL SHEATHING TO ALL <br />FACE NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH 16d SPIKES @ 24"oc STAGGERED. <br />Ss = 1.380 g, S1 = 0.526 g <br />HOLDOWN STUDS USING EDGE NAIL SPACING WHEN HOLDOWN STUD DOES NOT OCCUR AT PANEL <br />Sds = 0.920 g, Sd1 = 0.526 g <br />- DEVELOPMENT LENGTH 48 BAR DIAM. <br />EDGES. <br />EQUIVALENT LATERAL FORCE PROCEDURE <br />NAILS SHALL BE MANUFACTURED IN CANADA OR THE UNITED STATES IN SIZES AND TYPES AS <br />- DEVELOPMENT LENGTH, top bar* 64 BAR DIAM. <br />FOLLOWS, UNLESS NOTED OTHERWISE: <br />- LAP SPLICE LENGTH 64 BAR DIAM. <br />SHEATHING NAILS SHALL BE DRIVEN FLUSH BUT SHALL NOT FRACTURE THE SURFACE OF THE <br />- ALLOWABLE SOIL PRESSURE 2000 PSF AT V-6" DEPTH <br />SHEATHING. <br />- ALLOWABLE LATERAL PRESSURE 50 PCF / 35 PCF (RESTRAINED / UNRESTRAINED) <br />- LAP SPLICE LENGTH, top bar* 80 BAR DIAM. <br />PNEUMATIC NAILING - PLAIN SHANK, COATED OR GALVANIZED <br />- ALLOWABLE PASSIVE PRESSURE 300 PCF (F.S. OF 1.5 INCLUDED) <br />5. ALL WOOD PLATES IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE <br />-8d .131 DIAMETER x 2-1/2" MINIMUM LENGTH <br />- COEFFICIENT OF FRICTION 0.4 (F.S. OF 1.5 INLCUDED) <br />*TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12" OF CONCRETE IS <br />PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE. PROVIDE TWO LAYERS OF ASPHALT <br />- 1Od .131 DIAMETER x 3" MINIMUM LENGTH <br />- TRAFFIC SURCHARGE PRESSURE 70 PSF (AS APPLICABLE) <br />CAST IN THE MEMBER BELOW THE BAR. <br />IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC., AND CONCRETE <br />- 16d .131 DIAMETER x 3-1/2" MINIMUM LENGTH <br />- SEISMIC SURCHARGE PRESSURE 7H PSF (AS APPLICABLE) <br />OR MASONRY. ALL METAL CONNECTORS TO PRESSURE TREATED LUMBER SHALL BE HOT DIP <br />6. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: <br />GALVANIZED, INCLUDING WASHERS, NAILS, SCREWS, AND SIMPSON STRONG -TIE HANGERS, <br />STRAPS, AND PLATES, AND BOLTS LESS THAN 1/2' DIAMETER. <br />F. SPECIAL CONDITIONS <br />FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED <br />AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE <br />- FOOTING AND OTHER UNFORMED SURFACE, EARTH FACE 3" <br />CONTRACTOR TO COORDINATE ALL TRADES AND VERIFY DIMENSIONS IN THE FIELD. OBTAIN <br />BUILDING OFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE E.O.R. FOR <br />- FORMED SURFACE EXPOSED TO EARTH <br />6. NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS AND OTHER <br />OWNERS APPROVAL PRIOR TO ALL FIELD CHANGES. SEE ARCHITECTURAL DRAWINGS FOR ALL <br />POSSIBLE FOUNDATION REDESIGN. <br />CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY THE <br />FLOOR AND WALL OPENING DIMENSIONS AND LOCATIONS, FLOOR AND WALL FINISHES, ETC. <br />(i.e. WALL BELOW GROUND) OR WEATHER 2" <br />SIMPSON STRONG -TIE COMPANY, SAN LEANDRO, CALIFORNIA. EQUIVALENT DEVICES BY OTHER <br />2. LATERAL FORCE RESISTANCE SYSTEM <br />- SLAB AND WALL (INTERIOR FACE) 1-1/2" <br />MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR <br />LIGHT -FRAMED WOOD WALLS SHEATHED WITH WOOD STRUCTURAL PANELS, R e 6.5 <br />- CONCRETE NOT EXPOSED TO WEATHER OR EARTH 3/4" <br />GREATER LOAD CAPACITIES. SUBMIT MANUFACTURER'S CATALOG AND ICC REPORTS TO <br />DEFLECTION OF CANTILEVERS SHALL BE CLOSELY MONITORED BY THE CONTRACTOR DURING <br />ARCHITECT AND ENGINEER FOR REVIEW WHEN REQUESTING SUBSTITUTIONS. ALL SPECIFIED <br />CONSTRUCTION. CONTRACTOR TO VERIFY AND CONFIRM ALL POST CAPS AND POST BEARING <br />- PRIMARY REINFORCEMENT, TIES, STIRRUP, SPIRALS 1 1/2'° <br />FASTENERS MUST BE USED AND PROPER INSTALLATION PROCEDURES MUST BE OBSERVED IN <br />CONNECTIONS ARE INSTALLED IN STRICT CONFORMANCE TO THE STRUCTURAL DRAWING. <br />ORDER TO OBTAIN ICC APPROVED LOAD CAPACITIES. VERIFY THAT THE DIMENSIONS OF THE <br />CANTILEVERS IN WOOD FRAMING CAN DEFLECT UP TO 1/8" PER FOOT (I.E. 6' CANTILEVER MAY <br />7. CONCRETE WALL REINFORCING - PROVIDE THE FOLLOWING UNLESS DETAILED OTHERWISE: <br />SUPPORTING MEMBER ARE SUFFICIENT TO RECEIVE THE SPECIFIED FASTENERS. <br />DEFLECT 3/4"). IF DEFLECTION EXCEEDS 1/8" PER FOOT NOTIFY ENGINEER OF RECORD <br />IMMEDIATELY. BEFORE FINISHES ARE INSTALLED, FLOORS AT OR ABOVE CANTILEVERS MAY <br />7. STRUCTURAL CONNECTORS <br />REQUIRE LEVELING COMPOUND AND SOFFITS FURRED TO MAKE THEM LEVEL. <br />- 6" WALLS #4 @ 16" HORIZ. #4 @ 18" VERTICAL -1 CURTAIN @CENTER <br />- 8" WALLS #5 @ 18" HORIZ. #5 @ 18" VERTICAL 1 CURTAIN @ CENTER <br />ALL STRUCTURAL CONNECTORS TO BE BY SIMPSON STRONG TIE OR EQUAL. USE ZMAX/HDG HOT <br />DIPPED GALVANIZED OR STAINLESS -STEEL CONNECTORS AS A MINIMUM. USE FASTENERS <br />GALVANIZED PER ASTM A153. ALL PRESSURE TREATED LUMBER USED SHALL DE COMPATIBLE WITH <br />8. EPDXY GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH SIMPSON SET <br />ZMAX GALV. CONNECTORS, RE: SIMPSON STRONG -TIE CORROSION INFORMATION. <br />ADHESIVE BY SIMPSON STRONG TIE, PER ESR-2508, FOLLOWING MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. <br />(THIS IS A COMPREHENSIVE LIST OF ABBREVIATIONS, SOME OF WHICH MAY NOT APPEAR ON THESE DRAWINGS.) <br />AB <br />ANCHOR BOLT <br />CL <br />CENTERLINE <br />(E) <br />EXISTING <br />ACI <br />AMERICAN CONCRETE INSTITUTE <br />CLR <br />CLEAR <br />EA <br />EACH <br />ADDL <br />ADDITIONAL <br />CMU <br />CONCRETE MASONRY UNIT <br />EF <br />EACH FACE <br />ADJ <br />ADJACENT <br />COL <br />COLUMN <br />EL <br />ELEVATION <br />AFF <br />ABOVE FINISHED FLOOR <br />CONC <br />CONCRETE <br />ELEC <br />ELECTRICAL <br />AISC <br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />CONN <br />CONNECTION, CONNECT <br />ELEV <br />ELEVATOR <br />ALT <br />ALTERNATE <br />CONSTR <br />CONSTRUCTION <br />EMB <br />EMBED, EMBEDDED, EMBEDMENT <br />ANSI <br />AMERICAN NATIONAL STANDARDS INSTITUTE <br />CONT <br />CONTINUOUS <br />ENGR <br />ENGINEER <br />APA <br />AMERICAN PLYWOOD ASSOCIATION <br />CONTR <br />CONTRACTOR <br />EQ <br />EQUAL <br />APPROX <br />APPROXIMATE; APPROXIMATELY <br />COORD <br />COORDINATE <br />EQUIP <br />EQUIPMENT <br />ARCH <br />ARCHITECT; ARCHITECTURAL <br />CID <br />COMPLETE PENETRATION <br />ES <br />EACH SIDE <br />ASSY <br />CSK <br />COUNTERSINK; COUNTERSUNK <br />EW <br />EACH WAY <br />ASTM <br />AMERICAN SOCIETY FOR TESTING & MATERIALS <br />CTR <br />CENTER <br />EXP <br />EXPANSION; EXPOSED <br />AWS <br />AMERICAN WELDING SOCIETY <br />CU FT <br />CUBIC FOOT <br />EXP JT <br />EXPANSION JOINT <br />CU IN <br />CUBIC INCH <br />EXT <br />EXTERIOR <br />BID <br />CY <br />CUBIC YARD <br />BLDG <br />BUILDING <br />FD <br />FLOOR DRAIN <br />BLKG <br />BLOCKING <br />d <br />PENNY (NAILS) <br />FDN <br />FOUNDATION <br />BM <br />DBL <br />DOUBLE <br />FF <br />FAR FACE, FINISHED FLOOR <br />BMU <br />BRICK MASONRY UNIT(S) <br />DEPT <br />DEPARTMENT <br />FLR <br />FLOOR; FLOOR LINE <br />BOF <br />BOTTOM OF SLAB <br />DET <br />DETAIL <br />FLG <br />FLANGE <br />BOS <br />DIA <br />DIAMETER (SEE SYMBOLS) <br />FOC <br />FACE OF CONCRETE <br />BOT <br />BOTTOM <br />DIAG <br />DIAGONAL <br />FOM <br />FACE OF MASONRY <br />BRG <br />BEARING <br />DIAPH <br />DIAPHRAGM <br />FOS <br />FACE OF STUD <br />BEAM <br />DICA <br />DRILLED -IN CONCRETE ANCHOR <br />FS <br />FULL SIZE; FAR SIDE <br />C <br />STANDARD CHANNEL <br />DIM <br />DIMENSION <br />FT <br />FEET; FOOT <br />CG <br />CENTER OF GRAVITY <br />DN <br />DOWN <br />FTG <br />FOOTING <br />CGS <br />CENTER OF GRAVITY OF STRANDS <br />DO <br />DITTO <br />CIP <br />CAST -IN -PLACE <br />DWG <br />DRAWING <br />GA <br />GAUGE <br />CJ <br />CONSTRUCTION JOINT/CONTROL JOINT <br />DWL <br />DOWELS <br />GALV <br />GALVANIZED <br />GL <br />GLUE -LAMINATED <br />LOC <br />LOCATION <br />OPP <br />OPPOSITE <br />GWB <br />GYPSUM WALL BOARD <br />LONGIT <br />LONGITUDINAL <br />OSB <br />ORIENTED STRAND BOARD <br />GYP <br />GYPSUM <br />LSL <br />LONG SLOTTED HOLE <br />LVL <br />LAMINATED VENEER LUMBER <br />PAR <br />PARALLEL <br />HDR <br />HEADER <br />LWC <br />LIGHTWEIGHT CONCRETE <br />PERP <br />PERPENDICULAR <br />HNG <br />HANGER <br />PL <br />PLATE <br />HORIZ <br />HORIZONTAL <br />M <br />MISC SHAPE <br />PLWD <br />PLYWOOD <br />HP <br />HP SHAPE <br />MAS <br />MASONRY <br />PREFAB <br />PREFABRICATED <br />HS <br />HIGH STRENGTH <br />MATL <br />MATERIAL <br />PROP <br />PROPERTY <br />HT <br />HEIGHT <br />MAX <br />MAXIMUM <br />PSF <br />POUNDS PER SQUARE FOOT <br />MECH <br />MECHANICAL <br />PSI <br />POUNDS PER SQUARE INCH <br />ID <br />INSIDE DIAMETER <br />MFR <br />MANUFACTURER <br />PSL <br />PARALLEL STRAND LUMBER <br />IF <br />INSIDE FACE <br />MIN <br />MINIMUM; MINUTE <br />PT <br />POST TENSION <br />IN <br />INCH <br />MISC <br />MISCELLANEOUS <br />INCL <br />INCLUDE; INCLUDING; INCLUSIVE <br />MO <br />MASONRY OPENING <br />RD <br />ROOF DRAIN <br />INFO <br />INFORMATION <br />REF <br />REFERENCE <br />INT <br />INTERIOR <br />(N) <br />NEW <br />REINF <br />REINFORCE; REINFORCING <br />N <br />NORTH <br />REQ°D <br />REQUIRED <br />JT <br />JOINT <br />NF <br />NEAR FACE <br />RO <br />ROUGH OPENING <br />NFPA <br />NATIONAL FOREST PRODUCTS ASSOC <br />K <br />KIP = 1000 POUNDS <br />NIC <br />NOT IN CONTRACT <br />SCHED <br />SCHEDULE <br />KO <br />KNOCK -OUT <br />NOM <br />NOMINAL <br />SEC <br />SECTION <br />KSI <br />KIPS PER SQUARE INCH <br />INS <br />NEAR SIDE <br />SHT <br />SHEET <br />NTS <br />NOT TO SCALE <br />SHTG <br />SHEATHING; SHEETING <br />LAB <br />LABORATORY <br />SIM <br />SIMILAR <br />LB <br />POUND <br />oc <br />ON CENTER <br />SPA <br />SPACING, SPACE, SPACES <br />LF <br />LINEAL FOOT <br />OD <br />OUTSIDE DIAMETER <br />SPEC <br />SPECIFICATION <br />LLBB <br />LONG LEGS BACK-TO-BACK <br />OF <br />OUTSIDE FACE <br />SQ <br />SQUARE <br />LLH <br />LONG LEGS HORIZONTAL <br />OH <br />OPPOSITE HAND <br />STIR <br />STANDARD <br />LLV <br />LONG LEGS VERTICAL <br />OPNG <br />OPENING <br />STIFF <br />STIFFENER <br />STL STEEL <br />STRUCT STRUCTURAL <br />SYM SYMMETRICAL <br />T <br />TOP <br />T&B <br />TOP AND BOTTOM <br />T&G <br />TONGUE AND GROOVE <br />TEMP <br />TEMPERATURE <br />THK <br />THICKNESS <br />THRU <br />THROUGH <br />TOB <br />TOP OF BEAM <br />TOC <br />TOP OF CONCRETE; TOP OF CURB <br />TOF <br />TOP OF FOOTING <br />TOL <br />TOP OF LEDGER <br />TOM <br />TOP OF MASONRY <br />TOS <br />TOP OF STEEL, TOP OF STRUCTURE <br />TOW <br />TOP OF WALL <br />TS <br />TUBING, STRUCTURAL <br />TYP <br />TYPICAL <br />UBC <br />UNIFORM BUILDING CODE <br />UL <br />UNDERWRITER'S LABORATORY, INC. <br />UNO <br />UNLESS NOTED OTHERWISE <br />URM <br />UNREINFORCED MASONRY <br />UT <br />ULTRA -SONIC TEST <br />VERT <br />VERTICAL <br />W <br />WIDE FLANGE <br />WP <br />WORK POINT <br />WWF <br />WELDED WIRE FABRIC <br />CONCRETE WALL <br />INTERIOR STUD WALL BELOW; <br />�� <br />SHEAR WALL HOLDOWN AT <br />FRAMING LEVEL <br />W <br />SHEAR WALL ABOVE <br />FRAMING LEVEL <br />(DS) <br />(2) CS16 <br />i A <br />1 �;v1:PF <br />Permit #: <br />R2010-027 <br />Site Address <br />6522 WETMORE <br />Owner: <br />HOAGLAND JAM <br />Tenant: <br />[TenName] <br />App. Date: <br />10/14/2020 <br />Proposed Use: <br />RESIDENTIALALI <br />Description: <br />ADD ATTACHED t <br />SPACE AT UPPER <br />Reviewed By: <br />Office Set <br />DRAG STRUT- NAIL THRU <br />SHEATHING wi/ 8d @ 4"oc FOR <br />ENTIRE LENGTH OF MEMBER <br />Job Site Set <br />(2) SIMPSON CS16 x 30" STRAP, U.N.O. <br />HEADER,BEAM, JOIST END HANGER <br />>� - <br />m <br />s <br />�y <br />r <br />;3 <br />= <br />W co <br />s <br />ERATIO NS <br />iARAGE AND LIVING <br />LEVEL/ <br />Date: <br />-Fire/Planning Set <br />