Q5
<br />' A4.1 4 _
<br />44'-0" i
<br />----- — 20'-0}` _ 9 -- If -- — 24-0—
<br />12,60„ it 8, 0,! L 6! 3„ % 8Yu0" 0101, �-
<br />`) I
<br />--- 5 4, W 11 4'-3/4" , 2"_ 10 1�, I 4! 9"
<br />_
<br />--- i I
<br />S.G. G
<br />' i
<br />WHOLE HOUSE
<br />s
<br />i
<br />VENTILATION
<br />(i 1 /0W1 W02
<br />� I
<br />Ij co - —
<br />LNDRY. MASTER
<br />OPE 6 1N 12` iWIC
<br />SITTING
<br />_
<br />---
<br />_ —T ,
<br />I 7'-11„ ----- -- - ` i 4 -
<br />AREA
<br />E10),
<br />DDR � \D07t - _. _ r :, <`608 � '�� ; f �D06�
<br />{ I DOWN ( ` `✓
<br />D09�
<br />WJ �.� I CARBON
<br />T _ - cc MONOXIDE
<br />i
<br />-I I
<br />DETECTOR�.7.
<br />C01 /—— Cus �
<br />c�
<br />;
<br />cvi c`a ,
<br />LOSET
<br />. 1-11<D 10� if`I
<br />- _ �a107 ' D06 I SD
<br />Owl a SD �� J _.
<br />,.
<br />LINEN
<br />BATH 2
<br />BEDROOM CE t=
<br />4 ,
<br />IDQ6
<br />® Y _
<br />0 co
<br />BEDROOM
<br />MASTER
<br />MASTER
<br />I A _ W.I I
<br />A4.1 ® a T eel
<br />O t
<br />Q1A
<br />RIDGE W06 S.G.
<br />OWE
<br />I 60„
<br />12'-0" 2,-5" 5'-2"
<br />I 10,m7„ ,
<br />c�-- ---- — ----- -- - o
<br />I
<br />tag EGRESS
<br />O -
<br />��,� S.G. U�106 W07
<br />I
<br />,
<br />F
<br />I �I
<br />1
<br />6/12 6/12
<br />I
<br />SLOPE w SLOPE ( I }
<br />\.J �//+�i 9 _ _"''_.On. __.__}/�__`____�,.Qf1 __—._._..—_--._—_ r'=Ji'.__ __..._..._..._._.__�®'"tln
<br />� i i iJ
<br />rI i
<br />i I
<br />I, 24'-5'
<br />r — 1 r
<br />B I
<br />A4.1
<br />■ t , ` t..
<br />110
<br />bUALt:1/4" = V-0"
<br />LOWER ROOF VENTILATION CAL I
<br />ATTIC SPACE AREA: 262.5 SF
<br />VENTILATION REQUIRED: 262.5 SF / 150 = 1.75 SF REQUIRED
<br />AREA PROVIDE AT EAVES:
<br />39 L.F. OF EAVE VENTS @ 5.2 SQ. IN. / L.F. = 202.8 SQ.IN.
<br />202.8 SQ. IN. / 144 = 1 A0 SQ. FT. AT EAVE VENTILATION
<br />AREA PROVIDE BY LOUVER VENT:
<br />(1) 1'4"X2'-0" =2.66 SF - 20% REDUCTION = 2.12 SF
<br />TOTAL VENTILATION PROVIDED = 3.52 SQ. FT > 1.75 SQ, FT. REQ.
<br />I
<br />W08
<br />CAI
<br />ji
<br />m j
<br />I
<br />�It
<br />r
<br />�
<br />i �"
<br />- % & �'t
<br />HOUSE VENTILATION
<br />2015 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE
<br />HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE 1507.3.3(1) & TABLE
<br />1507.3.3(2), PROVIDE CONTROLS PER 1507.3.2 COMPLY WITH WSEC R403.6
<br />SYMBOL
<br />LOCATION
<br />MINIMUM FAN REQUIREMENTS
<br />I
<br />Bath & Powder
<br />Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4)
<br />_LI�L
<br />Kitchen
<br />Min. 400 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4)
<br />�
<br />(Make up air required)
<br />��
<br />Laundry
<br />Min. 180 cfm (INTERMITTENT) @ .025" wg -to function and be
<br />labeled as whale house fan (4-5 bedrooms 3001 <4500 SF).
<br />To operate 33% of every four hour period
<br />Habitable
<br />Fresh air diffuser; Min. 90 cfm (CONTINUOUS) (4-5 BEDROOM
<br />Spaces
<br />3001 <4,500 SF). All ductwork in heat recovery system shall be
<br />sized and installed per the manufacturer's instructions.
<br />DRYER VENT PER (TABLE M1507.4) VENTED TO OUTSIDE
<br />ALL FANS TO VENT TO OUTSIDE
<br />ALL DIMENSIONS ARE FACE OF FRAMING, CENTER OF COLUMN,
<br />OR FACE OF CONCRETE, U.N.O.
<br />CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS &
<br />CONDITIONS PRIOR TO CONSTRUCTION
<br />ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS
<br />PROVIDE FIRE BLOCKING AT ALL PLUMBING PENETRATIONS
<br />WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES
<br />DOOR JAMB 4" OFFSET FROM ADJACENT WALL, U,N.O.
<br />ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE
<br />TREATED,
<br />ALL WOOD IN CONTACT WITH CONCRETE TO BE
<br />PRESSURE TREATED
<br />SMOKE & CARBON MONOXIDE DETECTOR.
<br />*SHALL BE 110V INTERCONNECTED W/ BATTERY
<br />BACKUP.
<br />'SHALL SOUND AN ALARM AUDIBLE IN ALL BEDROOMS,
<br />SHALL BE INSTALLED ON EACH FLOOR AND IN ALL
<br />BEDROOMS.
<br />*SHALL BE INSTALLED IN EACH LOCATION WHERE
<br />THERE IS A CEILING CHANGE OF GREATER THAN 24"
<br />ALL STORAGE & SPACES UNDER STAIRS TO BE FINISHED WITH /
<br />1/2" G.W.B.
<br />DOOR BETWEEN HOUSE AND GARAGE SHALL BE SOLID CORE
<br />WOOD, SOLID OR HONEYCOMB STEEL DOOR, NOT LESS THAN
<br />1-3/8" THICKNESS.
<br />ALL TILE SHOWER / BATH WALL TO BE SHEATHED WITH FULL
<br />HEIGHT CONCRETE BACKER BOARD, ALL KITCHEN AND BATH
<br />GWB TO BE WATER RESISTANT TO CEILING.
<br />PROVIDE HANGING ROD & SHELF IN EACH CLOSETAS SHOWN
<br />ON PLANS, TYP,
<br />ALL WINDOW AND DOOR HEADER SHALL BE INSULATED WITH A
<br />MINIMUM OF R-10 RIGID INSULATION
<br />LOCATION OF HOUSE ADDRESS OR NUMBER TO BE PLAINLY
<br />VISIBLE AND LEGIBLE FROM THE STREET
<br />ENERGY CODE COMPLIANCE
<br />ENERGY CREDIT TABLE R406.2: OPTION 5a, and 5b FOR 1.5
<br />CREDITS
<br />FREASH AIR PROVIDED BY WHOLE -HOUSE FAN WITH FRESH AIR
<br />PORT (NET 4 SF IN MIN. OPENING) AT EACH HABITABLE ROOM. A
<br />TINIER OPERATES AN EXHAUST FAN WHICH PULLS OUTSIDE AIR
<br />THROUGH AIR INLETS LOCATED IN EACH HABITABLE ROOM.
<br />ALL NEW WINDOW AND NEW GLASS DOORS MUST HAVE U-
<br />FACTOR = 0.30 OR BETTER
<br />A MINIMUM OF 75% OF PERMANENTLY INSTALLED LAMPS IN
<br />LIGHTING FIXTURE SHALL BE HIGH -EFFICIENT LAMPS.
<br />ALL ,q
<br />�I-TOWER-HEAD AND KITCHEN
<br />CH SINK FAUCETS INSTALLED IN
<br />THE HOUSE SHALL BE RATED AT 1.75 GMP OR LESS. ALL
<br />OTHERS LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR
<br />LESS,
<br />ESO' A E 11P;-
<br />DESIGN - LC
<br />F2ESI Et-,ITIAL.-00N1IVIER,1 C I A L_
<br />160013 MOTOR PLACE
<br />LYNNWOOD, WA 9BOB 7
<br />CELL:425-877- 73'77
<br />EMAIL.:SIALERDES113N CLG AIL..r-om
<br />THESE DRAWINGS ARE COPYRIGHTED AND MAY
<br />NOT BE COPIED OR REDRAWN. WITHOUT THE
<br />WRITTEN PERMISSION OF S.IAL.ER DESIGN LLD.
<br />USE OF THIS DRAWING IS LIMITED. TO A SPECIFIC
<br />PROJECT FOR PERSONS NAMED HEREON AND
<br />FOR THE CONSTRUCTION OF ONE BUILDING. ANY
<br />OTHER USE .ORREUSE IS STRICTLY PROHIBITED
<br />WITHOUT THE WRITTEN CONSENT FROM SIALER
<br />DESIGN LLC.
<br />rt COPYRIGHT 2020
<br />kil-SIALER DESIGN LLC
<br />REVISIONS
<br />DATE DESCRIPTION
<br />PROJECT.-
<br />MAVERICK ADDITION
<br />CLIENT
<br />MAVERICK
<br />CONSULTING
<br />PO BOX 1154 EVERETT
<br />WA 98206
<br />REQUIRED GUARD SHALL HAVE OPENINGS FROM THE WALKING
<br />SURFACE TO THE REQUIRE GUAR HEIGHT WHICH ALLOW
<br />PASSAGE OF SPHERE 4 INCHES IN DIAMETER
<br />PER IRC - 301.5 CONCENTRATE LOAD. HANDRAILS AND GUARDS
<br />SHALL BE ABLE TO RESIST A SINGLE CONCENTRATE LOAD OF
<br />200 POUNDS, APPLIED IN ANY DIRECTION ATANY POINT ALONG
<br />THE TOP, AND TO TRANSFER THIS LOAD THROUGH THE
<br />SUPPORTS TO THE STRUCTURE,
<br />PER R312.2.1 - WINDOW SILL. IN DWELLING UNITS, WHERE THE
<br />OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN
<br />72 INCHES ABOVE FINISHED GRADE OR SURFACE BELOW, THE
<br />LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL
<br />BE A MINIMUM OF 24 INCHES OBOVE THE FINISHED FLOOR OF APPROVED
<br />THE ROOM IN WICH THE WINDOW IS LOCATED. OPERABL E
<br />SECTION OF WINDOW SHALL NOT PERMIT OPENINGS THAT
<br />ALLOW PASSAGE OFA4 INCHES IN DIAMETER SPHERE WHERE
<br />SUCH OPENING ARE LOCATED WITHIN 24 INCHES OF THE FINISH
<br />FLOOR.
<br />I
<br />KEY
<br />i
<br />NOTE
<br />i
<br />ON DEMAND WATER HEATER WITH MIN. EF 0.74
<br />HEAT ELEMENTS AND SWITCHES TO BE 18'
<br />-_✓ ABOVE CONCRETE SLAB
<br />- j GAS FURNACE
<br />- PROVIDED 2X8 BLOCK AT 54" A.F.F. FOR
<br />_ - THERMOSTAT PROJECT NUMBER: 2020-119
<br />1/2" GYPSUM WALL BOARD ON ALL WALLS AND DATE: 09/21/2020
<br />-- POST. 5/8" TYPE "X" G.W.B. SHALL BE INSTALLED CHECKED: LS
<br />PERPENDICULAR TO THE CEILING FRAMING AND
<br />SHALL BE FASTENED AT MAX. 6 INCHES O.C. DRAWN: L S
<br />FASTENER PER TABLE R702.3.5 STATUS: CONSTRUCTION DOCUMENTS
<br />/" ZERO -CLEARANCE METAL FIREPLACES TO BE
<br />INSTALLED PER MANUFACTURERS
<br />SPECIFICATIONS. PREFAB FIREPLACES TO BEAR
<br />THE STAMP OF AN APPROVED TESTING LAB.
<br />PROVIDED 6" DIM. OUTSIDE COMBUSTION AIR.
<br />HEARTH PER OWNER / BUILDER A2m6
<br />G .� 30" X 22" ATTIC ACCESS
<br />PLOT SCALE.: 1:1 PLOTTED ON:9120/20