Laserfiche WebLink
Q5 <br />' A4.1 4 _ <br />44'-0" i <br />----- — 20'-0}` _ 9 -- If -- — 24-0— <br />12,60„ it 8, 0,! L 6! 3„ % 8Yu0" 0101, �- <br />`) I <br />--- 5 4, W 11 4'-3/4" , 2"_ 10 1�, I 4! 9" <br />_ <br />--- i I <br />S.G. G <br />' i <br />WHOLE HOUSE <br />s <br />i <br />VENTILATION <br />(i 1 /0W1 W02 <br />� I <br />Ij co - — <br />LNDRY. MASTER <br />OPE 6 1N 12` iWIC <br />SITTING <br />_ <br />--- <br />_ —T , <br />I 7'-11„ ----- -- - ` i 4 - <br />AREA <br />E10), <br />DDR � \D07t - _. _ r :, <`608 � '�� ; f �D06� <br />{ I DOWN ( ` `✓ <br />D09� <br />WJ �.� I CARBON <br />T _ - cc MONOXIDE <br />i <br />-I I <br />DETECTOR�.7. <br />C01 /—— Cus � <br />c� <br />; <br />cvi c`a , <br />LOSET <br />. 1-11<D 10� if`I <br />- _ �a107 ' D06 I SD <br />Owl a SD �� J _. <br />,. <br />LINEN <br />BATH 2 <br />BEDROOM CE t= <br />4 , <br />IDQ6 <br />® Y _ <br />0 co <br />BEDROOM <br />MASTER <br />MASTER <br />I A _ W.I I <br />A4.1 ® a T eel <br />O t <br />Q1A <br />RIDGE W06 S.G. <br />OWE <br />I 60„ <br />12'-0" 2,-5" 5'-2" <br />I 10,m7„ , <br />c�-- ---- — ----- -- - o <br />I <br />tag EGRESS <br />O - <br />��,� S.G. U�106 W07 <br />I <br />, <br />F <br />I �I <br />1 <br />6/12 6/12 <br />I <br />SLOPE w SLOPE ( I } <br />\.J �//+�i 9 _ _"''_.On. __.__}/�__`____�,.Qf1 __—._._..—_--._—_ r'=Ji'.__ __..._..._..._._.__�®'"tln <br />� i i iJ <br />rI i <br />i I <br />I, 24'-5' <br />r — 1 r <br />B I <br />A4.1 <br />■ t , ` t.. <br />110 <br />bUALt:1/4" = V-0" <br />LOWER ROOF VENTILATION CAL I <br />ATTIC SPACE AREA: 262.5 SF <br />VENTILATION REQUIRED: 262.5 SF / 150 = 1.75 SF REQUIRED <br />AREA PROVIDE AT EAVES: <br />39 L.F. OF EAVE VENTS @ 5.2 SQ. IN. / L.F. = 202.8 SQ.IN. <br />202.8 SQ. IN. / 144 = 1 A0 SQ. FT. AT EAVE VENTILATION <br />AREA PROVIDE BY LOUVER VENT: <br />(1) 1'4"X2'-0" =2.66 SF - 20% REDUCTION = 2.12 SF <br />TOTAL VENTILATION PROVIDED = 3.52 SQ. FT > 1.75 SQ, FT. REQ. <br />I <br />W08 <br />CAI <br />ji <br />m j <br />I <br />�It <br />r <br />� <br />i �" <br />- % & �'t <br />HOUSE VENTILATION <br />2015 IRC - PROVIDE WHOLE HOUSE VENTILATION PER M1507, INTERMITTENT WHOLE <br />HOUSE VENTILATION USING EXHAUST FAN PER 1507.3 TABLE 1507.3.3(1) & TABLE <br />1507.3.3(2), PROVIDE CONTROLS PER 1507.3.2 COMPLY WITH WSEC R403.6 <br />SYMBOL <br />LOCATION <br />MINIMUM FAN REQUIREMENTS <br />I <br />Bath & Powder <br />Min. 50 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4) <br />_LI�L <br />Kitchen <br />Min. 400 cfm (INTERMITTENT) @ .025" WG (TABLE M1507.4) <br />� <br />(Make up air required) <br />�� <br />Laundry <br />Min. 180 cfm (INTERMITTENT) @ .025" wg -to function and be <br />labeled as whale house fan (4-5 bedrooms 3001 <4500 SF). <br />To operate 33% of every four hour period <br />Habitable <br />Fresh air diffuser; Min. 90 cfm (CONTINUOUS) (4-5 BEDROOM <br />Spaces <br />3001 <4,500 SF). All ductwork in heat recovery system shall be <br />sized and installed per the manufacturer's instructions. <br />DRYER VENT PER (TABLE M1507.4) VENTED TO OUTSIDE <br />ALL FANS TO VENT TO OUTSIDE <br />ALL DIMENSIONS ARE FACE OF FRAMING, CENTER OF COLUMN, <br />OR FACE OF CONCRETE, U.N.O. <br />CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & <br />CONDITIONS PRIOR TO CONSTRUCTION <br />ALL POSTS, BEAMS & HEADERS SEE STRUCTURAL DRAWINGS <br />PROVIDE FIRE BLOCKING AT ALL PLUMBING PENETRATIONS <br />WINDOWS & DOORS ARE SHOWN & NOTED AS NOMINAL SIZES <br />DOOR JAMB 4" OFFSET FROM ADJACENT WALL, U,N.O. <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE <br />TREATED, <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE <br />PRESSURE TREATED <br />SMOKE & CARBON MONOXIDE DETECTOR. <br />*SHALL BE 110V INTERCONNECTED W/ BATTERY <br />BACKUP. <br />'SHALL SOUND AN ALARM AUDIBLE IN ALL BEDROOMS, <br />SHALL BE INSTALLED ON EACH FLOOR AND IN ALL <br />BEDROOMS. <br />*SHALL BE INSTALLED IN EACH LOCATION WHERE <br />THERE IS A CEILING CHANGE OF GREATER THAN 24" <br />ALL STORAGE & SPACES UNDER STAIRS TO BE FINISHED WITH / <br />1/2" G.W.B. <br />DOOR BETWEEN HOUSE AND GARAGE SHALL BE SOLID CORE <br />WOOD, SOLID OR HONEYCOMB STEEL DOOR, NOT LESS THAN <br />1-3/8" THICKNESS. <br />ALL TILE SHOWER / BATH WALL TO BE SHEATHED WITH FULL <br />HEIGHT CONCRETE BACKER BOARD, ALL KITCHEN AND BATH <br />GWB TO BE WATER RESISTANT TO CEILING. <br />PROVIDE HANGING ROD & SHELF IN EACH CLOSETAS SHOWN <br />ON PLANS, TYP, <br />ALL WINDOW AND DOOR HEADER SHALL BE INSULATED WITH A <br />MINIMUM OF R-10 RIGID INSULATION <br />LOCATION OF HOUSE ADDRESS OR NUMBER TO BE PLAINLY <br />VISIBLE AND LEGIBLE FROM THE STREET <br />ENERGY CODE COMPLIANCE <br />ENERGY CREDIT TABLE R406.2: OPTION 5a, and 5b FOR 1.5 <br />CREDITS <br />FREASH AIR PROVIDED BY WHOLE -HOUSE FAN WITH FRESH AIR <br />PORT (NET 4 SF IN MIN. OPENING) AT EACH HABITABLE ROOM. A <br />TINIER OPERATES AN EXHAUST FAN WHICH PULLS OUTSIDE AIR <br />THROUGH AIR INLETS LOCATED IN EACH HABITABLE ROOM. <br />ALL NEW WINDOW AND NEW GLASS DOORS MUST HAVE U- <br />FACTOR = 0.30 OR BETTER <br />A MINIMUM OF 75% OF PERMANENTLY INSTALLED LAMPS IN <br />LIGHTING FIXTURE SHALL BE HIGH -EFFICIENT LAMPS. <br />ALL ,q <br />�I-TOWER-HEAD AND KITCHEN <br />CH SINK FAUCETS INSTALLED IN <br />THE HOUSE SHALL BE RATED AT 1.75 GMP OR LESS. ALL <br />OTHERS LAVATORY FAUCETS SHALL BE RATED AT 1.0 GPM OR <br />LESS, <br />ESO' A E 11P;- <br />DESIGN - LC <br />F2ESI Et-,ITIAL.-00N1IVIER,1 C I A L_ <br />160013 MOTOR PLACE <br />LYNNWOOD, WA 9BOB 7 <br />CELL:425-877- 73'77 <br />EMAIL.:SIALERDES113N CLG AIL..r-om <br />THESE DRAWINGS ARE COPYRIGHTED AND MAY <br />NOT BE COPIED OR REDRAWN. WITHOUT THE <br />WRITTEN PERMISSION OF S.IAL.ER DESIGN LLD. <br />USE OF THIS DRAWING IS LIMITED. TO A SPECIFIC <br />PROJECT FOR PERSONS NAMED HEREON AND <br />FOR THE CONSTRUCTION OF ONE BUILDING. ANY <br />OTHER USE .ORREUSE IS STRICTLY PROHIBITED <br />WITHOUT THE WRITTEN CONSENT FROM SIALER <br />DESIGN LLC. <br />rt COPYRIGHT 2020 <br />kil-SIALER DESIGN LLC <br />REVISIONS <br />DATE DESCRIPTION <br />PROJECT.- <br />MAVERICK ADDITION <br />CLIENT <br />MAVERICK <br />CONSULTING <br />PO BOX 1154 EVERETT <br />WA 98206 <br />REQUIRED GUARD SHALL HAVE OPENINGS FROM THE WALKING <br />SURFACE TO THE REQUIRE GUAR HEIGHT WHICH ALLOW <br />PASSAGE OF SPHERE 4 INCHES IN DIAMETER <br />PER IRC - 301.5 CONCENTRATE LOAD. HANDRAILS AND GUARDS <br />SHALL BE ABLE TO RESIST A SINGLE CONCENTRATE LOAD OF <br />200 POUNDS, APPLIED IN ANY DIRECTION ATANY POINT ALONG <br />THE TOP, AND TO TRANSFER THIS LOAD THROUGH THE <br />SUPPORTS TO THE STRUCTURE, <br />PER R312.2.1 - WINDOW SILL. IN DWELLING UNITS, WHERE THE <br />OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN <br />72 INCHES ABOVE FINISHED GRADE OR SURFACE BELOW, THE <br />LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL <br />BE A MINIMUM OF 24 INCHES OBOVE THE FINISHED FLOOR OF APPROVED <br />THE ROOM IN WICH THE WINDOW IS LOCATED. OPERABL E <br />SECTION OF WINDOW SHALL NOT PERMIT OPENINGS THAT <br />ALLOW PASSAGE OFA4 INCHES IN DIAMETER SPHERE WHERE <br />SUCH OPENING ARE LOCATED WITHIN 24 INCHES OF THE FINISH <br />FLOOR. <br />I <br />KEY <br />i <br />NOTE <br />i <br />ON DEMAND WATER HEATER WITH MIN. EF 0.74 <br />HEAT ELEMENTS AND SWITCHES TO BE 18' <br />-_✓ ABOVE CONCRETE SLAB <br />- j GAS FURNACE <br />- PROVIDED 2X8 BLOCK AT 54" A.F.F. FOR <br />_ - THERMOSTAT PROJECT NUMBER: 2020-119 <br />1/2" GYPSUM WALL BOARD ON ALL WALLS AND DATE: 09/21/2020 <br />-- POST. 5/8" TYPE "X" G.W.B. SHALL BE INSTALLED CHECKED: LS <br />PERPENDICULAR TO THE CEILING FRAMING AND <br />SHALL BE FASTENED AT MAX. 6 INCHES O.C. DRAWN: L S <br />FASTENER PER TABLE R702.3.5 STATUS: CONSTRUCTION DOCUMENTS <br />/" ZERO -CLEARANCE METAL FIREPLACES TO BE <br />INSTALLED PER MANUFACTURERS <br />SPECIFICATIONS. PREFAB FIREPLACES TO BEAR <br />THE STAMP OF AN APPROVED TESTING LAB. <br />PROVIDED 6" DIM. OUTSIDE COMBUSTION AIR. <br />HEARTH PER OWNER / BUILDER A2m6 <br />G .� 30" X 22" ATTIC ACCESS <br />PLOT SCALE.: 1:1 PLOTTED ON:9120/20 <br />