Laserfiche WebLink
SCALE - 3/8" = I '-0" <br />1. REFEK TO SHEETS S 1 .# FOR GENERAL STRUCTURAL NOTES, DESIGN CRITERIA, <br />TYPICAL DETAILS AND ABBREVIATIONS. <br />2. ROOF FRAMING TO BE 15/32" APA RATED SHEATHING OVER PRE -MANUFACTURED <br />TRUSSES @ 24" O,C. <br />3. PROVIDE 51MP50N H2.5A EA END OF TRUSSES PER 1/53. 1 <br />4. NAIL KOOF SHEATHING TO FRAMING W/ 8d AT G" O.C; AT FRAMED PANEL EDGES AND <br />OVER SHEAKWALLS AND 1 2" O.C. AT INTERIOR SUPPORTS, U.N.O. <br />5. "SW " INDICATES SHEAKWALL TYPE, REFER TO SHEAKWALL SCHEDULE ON SHEET <br />S 1 . 1 FOR TYPICAL SHEARWALL CONSTRUCTION. ALL EXTERIOR WALLS ARE SW I U.N.O. <br />G. KEFEK TO "WOOD FRAMING" ON S 1,0 FOR TYPICAL WALL FRAMING. <br />7. ALL SHOWN BUT NOT SPECIFIED HEADERS SHALL BE (2)2x8 MIN, U.N.0 <br />8. ALL GIRDER TRUSSES SHALL BE SUPPORTED BY (2)2xG OR (3)2x4 MIN, U.N.O. <br />9. ALL G.T. SHALL BE 2-PLY MIN, U.N.O. <br />10. REFEK TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS, DO NOT SCALE <br />DRAWINGS. <br />1 1. CONTRACTOR IS RESPONSIBLE FOK ALL TEMPORARY SHOKING. <br />12. CONTRACTOR SHALL NOTIFY EOK OF DISCREPANCIES BETWEEN FIELD CONDITIONS <br />AND THOSE SHOWN ON THIS PLAN PRIOR TO CONSTRUCTION. <br />13. ALL CONSTRUCTION MATERIALS CALLED OUT ON THE PLANS AND DETAILS AKE <br />NEW (N), U.N.O. <br />14. TRUSS MFR TO DESIGN ALL TRUSSES MARKED "D.S. TO TRANSFER LOAD FROM <br />TOP TO BOT CHORDS SHOWN IN PARANTHESIS. <br />STRUCTURAL BEARING / EXTERIOR', WALL SW I BELOW <br />NVA <br />EXISTING WALLS / NON-BRG WALLS <br />FLUSH / BOTTOM FLUSH BEAM <br />DROPPED BEAM / HEADER <br />NUMBER OF BUILT-UP BEARING STUDS FOR FLUSH BEAMS (TRIMMER <br />®(X) STUDS FOK HEADERS) BELOW. KEFEK TO TYP HEADER DETAIL FOK <br />NUMBER OF KING STUDS AND HARDWARE <br />® POST BELOW <br />X / -9X.X SECTION CUT -DETAIL NUMBER/ SHEET NUMBER <br />SPECIAL NAILING ZONE - PROVIDE FLAT 2x4 BLKG w/ 8d AT 4" O.C. AT <br />ALL PANEL EDGES AND 8d AT 1 2" O.C. IN THE FIELD <br />&T. GIRDER TRUSS <br />D.T.DRAG TRUSS - NAIL SHEATHING vv/8d @ 4" O.C. INTO ENTIRE LENGTH <br />OF MEMBER <br />(3- OF EVERETT <br />REVIWED FOR SIT <br />ZU FOOTNOTE "X" - KEF FOOTNOTES <br />ADDITIONAL STKAPPING KEQUIKMENTS PER PLAN / NOTES / DETAILS <br />E <br />D O <br />�e <br />O <br />cv <br />C� <br />LLJ <br />Lu <br />N > <br />LLJ 0 <br />EXP. 07/17/2022 <br />DATE: <br />1 1121121 <br />PROJECT #: <br />21-022 <br />Roof <br />fKAMING <br />FLAB <br />tA.-k m <br />