My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3324 TULALIP AVE 2022-04-29
>
Address Records
>
TULALIP AVE
>
3324
>
3324 TULALIP AVE 2022-04-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2022 8:34:01 AM
Creation date
4/29/2022 8:31:14 AM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3324
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8 of 26 <br /> A PROJECT NO. SHEET NO. <br /> flik <br /> S210728-5XR <br /> wr/44iA )........• PROJECT 3324 TULALIP AVE,EVERETT, WA 98201 <br /> LONGITUDE SUBJECT Foundation Stabilization/Jacking <br /> ONE TWENTY° <br /> ENGINEERING&DESIGN BY FY DATE 08/31/2021 <br /> ideal Foundation Systems 2-7/8"0 Helical Pile(0.203-inch wall thickness)-Soil Capacity per ESR•3750 <br /> DIGGA 10K Drive Torque Correlation Factor, K, Ultimate Axial Compressive Allowable Axial Compressive <br /> Head Torque, T <br /> Pressure (Jr'!bs) Compression Capacity, P.=K,'T Capacity, P.=05'P <br /> (psi) lit') (kips) (kips) <br /> 500 1,740 9 15.7 7.8 <br /> 600 2,088 9 18.8 9 4 <br /> 700 2,436 9 21.9 11.0 <br /> 800 2,784 9 25.1 12.5 <br /> 900 3,132 9 28.2 14,1 <br /> 1000 3,480 9 31.3 15.7 <br /> 1100 3,828 9 34.5 17.2 <br /> 1200 4.176 9 37.6 18.8 <br /> 1300 4524 9 40.7 20.4 <br /> 1400 4,872 9 43.8 21.9 <br /> 1500 5,220 9 47.0 23.5 <br /> 1600 5,568 9 50.1 25.1 <br /> 1700 5,916 9 53.2 26.6 <br /> 1800 6,264 9 56 4 28.2 <br /> MAX 1900 6,612 9 595 29.8 'See Note viii <br /> 2000 6,960 9 62.6 31.3 <br /> 2100 7,308 9 65.8 32.9 <br /> 2200 7,656 9 68.9 34.5 <br /> 2300 8.000 9 72.0 36.0 'See Note ii <br /> I.)DIGGA 10K Drive Head differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii.)Per Table 5A of ESR-3750 and Ideal Manufacturing Inc.,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,300 <br /> ft'Ibs.Final installation torque shall not.inl eed this value. <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the structural <br /> package,but shall not exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv.)Refer to ESR-3750 and Ideal Manufacturing,Inc.documents for additional Information and requirements. <br /> v.)Definitions per E5R-3750: <br /> T=Final Installation torque in ft'Ibs;the last torque reading taken during pile installation,using,for example,the torque reading <br /> instruments connected to the installation equipment. <br /> K,=Torque correlation factor per ESR-3750 <br /> P„=Ultimate axial compressive capacity(in kips)of helical pile <br /> P„=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:P._(T'10/2 <br /> vii.)1 kip=1,000 lbs <br /> viii.)Per Note 3 of Ideal Group Dwg No.:278TFG dated 4/23/20,the ultimate structural capacity for the 2 7/8"TRU-FORCE Underpinning Bracket is limited to <br /> 60 kips. <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.