(E)DECK <br /> IE15'-1 RESS"SL i p <br /> EGRESS _ )-:. <br /> i--- II'`.i" Ir{�e'f01®`t <br /> JArchitect+wre <br /> (E) I DW PLAN NOTES *De'Sit3Nf <br /> (E)BATH I (E)KITCHEN (E)DINING 1. GUARDRAILS TO BE+36"MIN.ABOVE FLOOR,LANDING,DECK,OR NOSING. <br /> 7'8"CLG.HT. ob 3 0 7'8"CLG.HT. 7'8"CLG.HT. BALUSTRADES AT GUARDRAILS SPACED SO THAT A 4"DIA.SPHERE CAN NOT 206-355-1263 bluefootdesign.com <br /> (E)BEDROOM 2 ,N 5 <br /> NEW 36z52 PASS. POUL580 WA <br /> s 2.HANDRAILS TO BE CONTINUOUS,+34"TO+36"ABOVE STAIR NOSING AND <br /> 7'8"CLG.HT. ISLAND LANDINGS.HANDRAIL TO BE 1-1/2"DIA.,MOUNTED TO MAINTAIN 1-1/2"CLEAR These drawing,are instruments or service <br /> BETWEEN HANDRAIL AND WALL OR GUARDRAIL.RETURN HANDRAIL ENDS and shad remain Me property of the <br /> SO€ e C INTO ADJACENT WALLS OR NEWEL POSTS. they are mtect ode whether <br /> rexecuted project <br /> not lheyorre <br /> 3.REFER TO SPECIFICATIONS S FOR ADDITIONAL FOR <br /> MATERIALS AND REQUIREMENTS. not on be used he 6y the owns to any other <br /> EXT'G.CASED 4.REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. parser je other projects air ant in extensions in <br /> (-----, re' OPENING the protect except by agreement in writing <br /> and with appropriate compensation to Me <br /> architect. <br /> t SD O LEGEND - <br /> OO SMOKE DETECTOR,110 V.HARDWIRED.INTERCONNECT SMOKE PROJECT <br /> I S.D.DETECTOR,110 V.HARDWIRED.INTERCONNECT BATTERY <br /> BACKUP.TO BE LISTED IN ACCORDANCE WITH UL 217,AND KEIM RESIDENCE <br /> A INSTALLED IN ACCORDANCE WITH NFPA 72. - <br /> ER NOTESII NG - <br /> COWITTHON UL 2034,0 AND OE ALARM.TO BE LISTED AS INSTALLED IN ACCORDANCE WITH ITHE IRC <br /> L J SD O .1•11111111L_____ 1 AND MANUFACTURER'S INSTRUCTIONS. - <br /> (EIATTIC <br /> ACCESS .� HANDRAIL O EXHAUST FAN,INTERMITTENTLY OPERATED,SWITCH <br /> PER NOTES E.F. <br /> (E)BEDROOM 1 CONTROLLED,EEXTERIOR. <br /> ALL.EXHAUSTTHROMS,FANS&VENTS TOBE EXHAUSYED ADDRESS <br /> (E)LIVING TO THE EXTERIOR.BATHROOMS,TOILET ROOMS,LAUNDRY <br /> 7'8"CLG.HT. DN UP ROOM AREAS:50 CFM MIN.KITCHEN:100 CFM MIN. 5505 WETMORE AVE <br /> (E)ENTRY T8"CLG.Hi. -- NEW FRAMED WALL <br /> EVERETT,WA _ <br /> (E)5'-10"x3'8"SL r EXISTING WALL/ITEM TO BE DEMO'D AND/OR REMOVED AND STORED 98203 <br /> EGRESS <br /> r EXISTING FRAMED WALL REMAINS <br /> AD DRAWN BY <br /> FULL-DEPTH <br /> BLOCKING @48"O.C. UPPER FLOOR PLAN )V C ECKED <br /> �, p SCALE <br /> . •• •� O ISSUE DATES <br /> ,-.,aL E 12/16/2021 - <br /> JOIST PER PLAN 12z SIMPSON STC CLIP® PERMIT SET - <br /> NON-BEARING WALL � 48"O.C.SLOT VERTICAL <br /> REVISIONS <br /> PER ARCH DRAWINGS (NAIL AT MID-HEIGHT OF SLOT) <br /> --4- r EXT'G.DECK ABV. <br /> WALL PARALLEL TO ROOF/FLOOR FRAMING <br /> 1 I riutAtArt ru a ht,riq -_ <br /> ,✓6�1 1 O� J4LL cAti/Lrr5S. - <br /> SIMPSON STC CLIP @ <br /> JOIST PER PLAN 48"O.C.SLOT VERTICAL - - �. ( TABLE R602.3(1) <br /> 76x48 I/ FASTENER SCHEDULE FOR STRUCTURAL MEMBERS <br /> NON-BEARING WALL (NAIL AT MID-HEIGHT OF SLOT) ® SHOWER L/ ITEM DEC,CRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER... SPACING OF FASTENERS - <br /> SEE ARCH DRAWINGS FLAT FRAME Rom <br /> FURRED WALL,TYP. 1 Blocking between joists or ratters to top plate,toe 3.8d(2 Pi.x 0.113`) - _ <br /> CONDITIONED nail <br /> NEW LOCATION 2 Ceiling joists to plate,toe nail 3-8d(2 SY x 0.1131 - <br /> WALLPERPENDICULARTOROOF/FLOOR FRAMING FOR EXT'G. II© SPACE 3 Ceding joktnot adachetl to paraded attar,Laps over 3.104 --^ <br /> WASHER&DRYER holler a race nail <br /> FAMILY \ i 4 cdlar'learatter,Rape ran,o<,-vat-xzo gaga alad t3-xo.,ze') <br /> D -� BATH ROOM SeeP <br /> 5 Rattterto plate.toe nad 2.16d(3 14 x 0.135-1 - <br /> EF EXT'G.1 3/8"SOLID -(EIEF 7'-3"CLG.HT. 8'-0"CLG.HT. Y 6 Roar rafters to edge,valley or hip rafters: - - <br /> toenail 4-16d1 'a xo.135� <br /> 0TYPICAL NON-STRUCTURAL WALL SUPPORT(TOP) CORE WOOD 20 1 FXT'G.4x6 - facemd 316tl13Yx0.135"1 <br /> MIN.RATED DOOR POST Wall <br /> T Builtarpmmer studs-lace roil Sd I3 r x 0.126') 24-aC. <br /> W/SELF CLOSER (E)6x138EAM ABV. B Abutting slues atimerseeling well comers.lace nad Isd(355'x0.135i ,roc <br /> -w 9 Bunt.up header,two pieces with'h•c (3`,nr I6d(3' "00.1351 16"o.c.along each edge <br /> (EI6x13 BEAM ABV. 4 10 Continued header,Iwo pieces 160 13R'x 00.1351 16'o.c.along each edge DRAWING INDEX <br /> SOFFIT @ <br /> / T-0"A.F.F. , 11 Caaimxe0a header to stud,toe nail 4-80(2',e x 0.1131 <br /> . <br /> SD/CO 2•-1" 12 Double <br /> seas,face nail 10d(3-x0.126-1 24•oc. FLOOR PLANS <br /> e e 13 Double top plates.lace nail 10d(7 p13.1281 24•o.c <br /> (E)GARAGE - L----=a-a 14 Double top pates,minimum 24.inch onset m end e-16d13W'00.1351 <br /> 8,0"CLG.HT. UP ----- ^' SD tR 2 i keels,lace <br /> area - <br /> % NON-BEARING WALL -_--- 3 m 15 Soto a,blocking. al 6a.G <br /> IE)FURN .1160(3td x 00.1351 <br /> 16 Sole plate to foist or blocking a braced wall panels 16'c.c. <br /> PER ARCH DRAWINGS i/ Y - - z o 17 Stud losole plate.roe nun s1-a�o�zexo..113j - <br /> EXT'G.CONC.SLAB POWER DRIVEN FASTENER O/� <br /> a or <br /> BEDROOM3 3 €., 2.16d pve x 00.1351 CERTIFICATION <br /> n t EXT'G.5/8"TYPE'X'-' 8'-0"CLG.HT. ...." \ 18 Tap or sale Plats a stud,and nail ---- 2-18013'Y x 00.135"1 - <br /> /" I FIRE RATED GYP.BD. DN UP WZ o, 19 Top pales.laps at comers and intersections.face z d0d(3'x 0.126'1 <br /> �� 4° a a ON GARAGE CEILING nag - <br /> as - )ENTRY 20 1-brace to eachslud and plate.lace nail zed fz�f xo,13T <br /> - <br /> a° &ONE LAYER OF 1/2" ..... 1010'-0"x3'0' z rapes 1'4 <br /> ON GARAGE WALL (2'-0"SL/8'-0"PLC/2-0 SU (EIEPB I z1 r.s•shea,mng to each tearing,lace nail z-ed(z•dx0 n3•) �''J4E CSTrrE'1 <br /> RR00TO BE T• A.F.F." 2 staples PA.. <br /> rl' <br /> 22 f':8'alreaNing to each bearing,lace nail 283 staples <br /> ,r 4t <br /> \ \ \ saapesli 4Y V <br /> 23 Wder Nan l-"8-sheathing to eachbea,i4.lace 3-8e(2,F x0113-) <br /> WALL PERPENDICULAR TO FLOOR FRAMING - - - - - - - - - - earl aazapesr,. vAr,T.,qSt,.-ct <br /> EXT'G.FLOOR ABV. EXT'G.FLOOR AB. 24 .dostto sin or guar.tee nad lad 12'n•x 11, - - <br /> 17'-3" 25 Ran fast to top plate,tea nail goof apPlimars 8d12•�x0.113.1 6-p.c. <br /> / Al fin/ O0�'l 4 else, - <br /> 28 Rim joist or blocking to sill plate,toe nail 80(2 LYx0.t t3} Vox_ <br /> 27 1'x b-sublime or less a each joist,lace nail 2427 2-8 12'ie x 0.1131 <br /> O TYPICAL NON-STRUCTURAL WALL SUPPORT(BOTTOM) LOWER FLOOR PLAN / y �� tires26 2-sub as,lolalatorgirder,blindandfatenail 2stapes 3 SHEET NO <br /> 1 y�ff y�J/A/ z-,so1a''.00.lasl <br /> V4„=1,-0" L/L /4l L� 29 r - - <br /> �( �) I planks(plank fi beam 6 roof) yarpq� V2-16�de(73�h'x 0z0e13�5T a`,C® ,each beadrg <br /> 0'',, /� 1✓ / 2.1e '•'O H 3o Bel w aiaera am oeams.z.inch wmhe a \d l T l 1 V L�/L'2@ET jn/{ � andsttagge}med.Two�tsat A2. <br /> 31 ledger strut supp0di Joists air l,'�P\ r O.FT, l f Lv_�_�w�_��.���\ tT <br /> 2_ ) 2 <br />