Laserfiche WebLink
How many down spouts are currently connected to the sewer: 0 <br /> Does side sewer have slope: No, not inside the house. It has slope outside home. <br /> Depth of side sewer 10ft from house: 5' <br /> Sewer Report: <br /> Material: Concrete <br /> Sewer Length: 87' <br /> Condition: poor <br /> Explain: No grade under basement floor <br /> Recommend: Either break concrete and run new line to outside or run new line directly <br /> outside and bring new side sewer to the cleanout location. <br /> Any additional comments: <br /> • Shared line with neighbor most of it is new now after new city sewer installed in <br /> street. <br /> Problems Identified <br /> 1) This home does not currently have a backwater valve to prevent backups during high <br /> flow surcharge events. <br /> Solution: <br /> Install backwater valve on side sewer. <br /> 2) No Drain at back stairs to basement <br /> Solution A: Install new drain to current plumbing <br /> Solution B: Install new drain using sump pump to remove water to yard or sewer. <br /> 3) Inside the house side sewer is cast iron with a major flat spot holding debris. This <br /> could cause a back up at any time. <br /> Solution: Replace inside section by cutting concrete and installing new line in place of <br /> the old line and path or take out new line outside and bring sewer to new spot outside. <br />