Laserfiche WebLink
I r 1 <br /> 1.NO ALL NEW CONDUCTORS TO BE INSTALLED SHALL BE COPPER. �111... IIJII�JJ/ „111V� F-a• <br /> ALL CONDUCTORS SHALL BE THHW, THWN,THWN-2, XHHW, <br /> OR XHHW-2 UNLESS NOTED OTHERWISE. <br /> 2. CONTRACTOR IS TO FIELD VERIFY ALL EXISTING ITEMS SHOWN <br /> ON THE ELECTRICAL ONE-LINE DIAGRAM AND NOTIFY THE 8960.-AL.DERWOOD ROAD <br /> ENGINEER OF ANY DISCREPANCIES. PORTLAND,OR 97220 <br /> 3. ALL GROUNDING AND BONDING PER THE NEC. Cflgi . - <br /> CROWN <br /> v CASTLE <br /> 1505 WESTL KEAVENUE NORTH,SUITE 800 <br /> SEATTLE,WA 98109 <br /> • EXISTING UTILITY COMPANY TRANSFORMER <br /> P.MARSHALL&ASSOCIATES <br /> L _ _ J 6801 PORTWF_ST DR.,SUITE 100 <br /> EXISTING WIRE AND CONDOHOUSTON,TX 77024 <br /> T-MOBILE SITU: LOCATION: VOLTAGE:240/12010 MOUNTING/ENCLOSURE: EXISTING/ NEMA 3R T-MOBILE SITE NUMBER: <br /> EXISTING 2COA.120/240V,I03W,NEMA 3R <br /> SEO1605A(EXISTING) MAINC/B: 200 AMPS AVAIL.FAULT CURRENT: EXISTING METER ENCLOSURE SE01605A <br /> H-FRAME <br /> 9/23/2021 BUS RATING: 200 AMPS ,SHORT CIRCUIT RATING: EXISTING r <br /> POLES WIRE&CONDUIT TYPE DESCRIPTION KVA CKT A 8 CKT KVA DESCRIPTION TYPE WIRE&CONDUIT POLES L _ _ J <br /> 20/1 EXISTING E UNKNOWN 1.92 1 2.02 16 0.10 SURGE PROTECTION EQ EXISITNG 60/2 <br /> - EQ - 2 0.10 17 0.10 - EQ - - BU#:823968 <br /> HPL3 CABINET - - EQ - 12.00 3 13.92 18 1.92 UNKNOWN E EXISTING 20/1 EVERETT WATER TANK <br /> BREAKER 200/2 EXISTING EQ HPL3 CABINET 12.00 4 13.92 19 1.92 UNKNOWN E EXISITNG 20/1 I- - - i <br /> - EQ - 5 0.50 20 0.50 TECH LIGHT L EXISITNG 20/1 <br /> 20/1 EXISTING H GENERATOR BLOCK HEATER 1.00 6 1.00 21 KNOCKOUT - I EXISTING 2(?0A,240V,2-POLE,SERVICE RATED. <br /> 20/1 EXISTING L TECH LIGHT 0.50 7 0.50 22 KNOCKOUT - (/ NEMA 3R DISCONNECT 319 76TF3 ST.SW <br /> KNOCKOUT 8 23 KNOCKOUT - I o EVERETT,WA 98203 <br /> - KNOCKOUT 9 24 KNOCKOUT - <br /> - KNOCKOUT 10 25 KNOCKOUT <br /> - KNOCKOUT 11 26 KNOCKOUT - L _ _ J <br /> - KNOCKOUT 12 27 KNOCKOUT - <br /> - KNOCKOUT 13 28 KNOCKOUT - EXISTING INTERSECT <br /> KNOCKOUT 14 29 KNOCKOUT - CAM LOK CONNECTION EXISTING WIRE AND CONDUIT <br /> - KNOCKOUT is 30 KNOCKOUT - 0EXISTING 97'-0"MONOPOLE <br /> PHASE TOTAL 16.9 15.0 KVA I ,\ <br /> TOTAL CONNECTED LOADI 32.0 kVA I 133 A <br /> ISSUED FOR: <br /> TOTAL DEMAND LOAD 33.7 kVA I 140A REV DATE DRW:N DESCRIPTION DES./QA <br /> LOAD CONN.LOAD DEMAND DESIGN LOAD 200/2 200/2 A 07/12/21 SD PRELIMINARY HS <br /> DESCRIPTION EXISTING 200A,120/240V,IOW.NEMA 3R.PPC WEE INTEGRATED <br /> TYPE KVA AMPS FACTOR KVA AMPS I MANUAL TRANSFER SWITCH,LOAD CENTER,AND FACTORY WIRED 0 09/13/21 CS FINAL CD HS <br /> L LIGHTING• 1.0 4.2 1.25 1.3 5.2 + + GENERATOR INTERFACE FOR PORTABLE GENERATOR CONNECTION. 1 US/TV/21 CS FINAL.REVISION FLS <br /> um: LOCATION OF MAIN BONDING JUMPER. <br /> R RECEPTACLE 0.0 0.0 NEC 0.0 0.0 <br /> M MOTOR 0.0 0.0 NEC 0.0 0.0 r <br /> H HEATING 1.0 4.2 1.00 1.0 4.2 <br /> AC HVAC 0.0 0.0 1.00 0.0 0.0 <br /> EQ EQUIPMENT 24.2 100.8 1.00 24.2 100.8 <br /> E EXISTING 5.8 24.0 1.25 7.2 30.0 <br /> (3) 3/0 AWG,(1)#6 GROUND,2'CONDUIT <br /> "ALL EQUIPMENT LOADS CONSIDERED CONTINUOUS LOADS <br /> 200/2 <br /> ''...-- GI itK: '. <br /> 1°,141 <br /> 4441ONAI.$A0 ' <br /> WV NUMBER:804-108-TM <br /> EXISTING PURCELL <br /> HPL3 CABINET <br /> LAX <br /> IT IS A VIOLLATIONN LAW <br /> OF FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> OF A LICENSED PROFESSIONAL SSTONAI.ENGINEER, <br /> C I TY OF E VE R E TT <br /> TO ALTER THIS DC1Cl71fENT. <br /> PM&A JOB#: <br /> REVIEWED FOR PERMIT 21CCT7M-101 <br /> SHEET NUMBER: REVISION: <br /> 0 <br /> CALEN NOT TODSCALE °SCALEI:NNOT OS ALE ` H1-1 <br />