Laserfiche WebLink
2/22/2022 City of Everett Page /2.2:07:50P <br /> 11 <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. M2201-010 Site Address 520 92ND ST SE <br /> Applied 1/5/2022 Applicant Charity Teeters Lot <br /> Approved 1/6/2022 Owner GRUBER SILVIU Block <br /> Issued 1/6/2022 Contractor ADVANCED INSTALLATION INC Tract <br /> Parent Permit No. Description Installation of a freestanding decorative gas stove <br /> Notes Travis Industries NG Berkshire decorative stove in living room <br /> Scheduled Completed Tvne Inspector Result Remarks Inspector's Comments <br /> GAS 03-FINAL MPI eTRAKiT Inspection 2/1/2022 4:26 PM ADVANCED <br /> Request INSTALLATION INC <br /> gas line only-venting to be rerouted soon <br /> Contact Name:Silviu Gruber <br /> Site Address:520 92ND ST SE <br /> Phone:2066979740 <br /> e-Mail:grubersz@hotmail.com <br /> (Canceled-eTRAKiT-2/2/2022 3:31:54 <br /> PM) <br /> 2/1/2022 2/1/2022 GAS 03-FINAL JJM CORRECTION eTRAKiT Inspection 1/31/2022 12:24 PM ADVANCED <br /> Request INSTALLATION INC <br /> morning please <br /> Contact Name:Silviu Gruber <br /> Site Address:520 92ND ST SE <br /> Phone:2066979740 <br /> e-Mail:grubersz@hotmail.com <br /> (2/1/2022 9:44 AM JJM) <br /> -Gas test has dropped to under 4PSI.Reset <br /> test to 15 PSi and recall for inspection. <br /> 2/1/2022 2/1/2022 MECH 04-ROUGH JJM CORRECTION eTRAKiT Inspection 1/31/2022 12:24 PM ADVANCED <br /> IN Request INSTALLATION INC <br /> morning please <br /> Contact Name:Silviu Gruber <br /> Site Address:520 92ND ST SE <br /> Phone:2066979740 <br /> e-Mail:grubersz@hotmail.com <br /> (2/1/2022 9:44 AM JJM) <br /> • -Gas test has fallen to under 4 PSI.Reset to <br /> 15 PSI and recall for inspection. <br /> 2/9/2022 2/9/2022 MECH 04-ROUGH JJM APPROVAL eTRAKiT Inspection 2/8/2022 11:24 AM ADVANCED <br /> IN Request INSTALLATION INC <br /> Morning preferred.thank you <br /> Contact Name:Silviu Gruber <br /> Site Address:520 92ND ST SE <br /> Phone:2066979740 <br /> e-Mail:grubersz@hotmail.com <br /> 2/9/2022 2/9/2022 GAS 03-FINAL JJM NOT READY eTRAKiT Inspection 2/8/2022 11:24 AM ADVANCED <br /> Request INSTALLATION INC <br /> Morning preferred.thank you <br /> Contact Name:Silviu Gruber <br /> Site Address:520 92ND ST SE <br /> Phone:2066979740 <br /> e-Mail:grubersz@hotmail.com <br /> 2/9/2022 2/9/2022 GAS 01-ROUGH IN JJM APPROVAL (2/9/2022 8:55 AM JJM) <br /> -Gas test ok at 15 PSI. <br /> INSP12 <br /> SYS T1_MS <br />