Laserfiche WebLink
• <br /> NAME OF AFH: <br /> SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK ALL APPLICABLE BOXES;MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE RESIDENT <br /> BEDROOM DESIGNATIONS OF A B C D E AND FAND CLASSIFICATION CODES,NS1 OR NS2. <br /> SECTION 5—BUILDING INSPECTOR'S INSPECTION CHECKLIST <br /> R325.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. <br /> Type NS1—where 1 means of egress at grade level(has no stairs)or ramp constructed compliant with R325.9 is provided to evacuate residents to public area. <br /> Type NS2—where 2 means of egress at grade level(both have no stairs)or ramps constructed compliant with R325.9 are provided to evacuate residents to public area. <br /> SLEEPING ROOM A ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> Closet door's are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM B ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high; at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM C ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high; at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor;no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM D ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high; at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM E ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> --------- <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted ❑ ❑ <br /> SLEEPING ROOM F ❑Type S ❑Type NS1 ❑Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes ❑No Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.1.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor; no steps under window permitted ❑ ❑ <br /> Effective: 2013 July 01 <br /> 2 5 Updated: 2013 June <br />