• • <br /> Mr. Martin Reimers <br /> Concept Architecture, LLC <br /> Plan Check Number: B2107-070, First Building Review <br /> August 16, 2021 <br /> Architectural <br /> 1. The project requires installation of grab bars on the water bathrooms. The"Grab Bar Legend" <br /> on Sheet A2.1 is not sufficient to specify all requirements. Details showing the requirements <br /> should be included in the construction drawings. Additional requirements including but not <br /> limited to heights, spacing, and placement along walls should be shown. The details should <br /> include blocking capable of supporting a minimum 200-pound load. See Sections R106.1.1 and <br /> R330.8, and Table R301.5. <br /> 2. Bedrooms 1 through 4 are shown as having existing windows. The minimum requirements for <br /> emergency egress opening should be specified in the construction drawings and verified in the <br /> field. See Section R310.2. <br /> 3. The locations of the smoke and CO alarms are shown on Sheet E2.1. See Sections R314 and <br /> R315. The following comments should be addressed: <br /> a. Alarms are required in the immediate vicinity of sleeping areas. Additional alarms should be <br /> provided by the doors for Bedroom 4 and Bedrooms 5 and 6. <br /> b. The"Electrical Legend"should be revised to require that the alarms be hardwired, <br /> interconnected, and provided with back-up battery power. <br /> 4. Bedroom 6 on Sheet A2.1 is shown to abut an existing masonry fireplace with unknown <br /> construction around the sides and back of the fire box. Details showing that the construction <br /> complies with Section R1001.11 should be included. <br /> 5. The construction drawings should specify an exhaust fan in the Kitchen. See Sections R303.4 <br /> and Table 1505.4.4(1). <br /> 6. The Main Level Plan 1/A2.1 shows an exterior ramp on the north side of the building. The plan <br /> specifies a 1:12 slope. See Section R106.1.1. The following comments should be addressed: <br /> a. Handrails should be shown on both sides of the ramp per Section R330.9.1. Details for the <br /> handrails should be provided. The handrails should be designed to support a minimum 200- <br /> pound load per Table R301.5. <br /> b. A minimum 3-foot landing is required at each end of the ramp; the west landing does not <br /> appear to be shown. See Section R311.8.2. <br /> Structural <br /> 1. The project includes demolition of the exterior wall for new openings. Structural details for the <br /> new framing should be included in the construction drawings. Fasteners should be specified <br /> per Table R602.3(1). See Section R106.1.1 and R301.1. <br /> 2. Detail 3/A4.1 should specify a minimum 2-inch clearance between the exterior slab-on-grade on <br /> non-preservative-treated wood materials. See Section R317.1 Item 5. <br /> 0 3200 Cedar Street 0 425.257.8810 everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/sermits <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.