My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2312 W CASINO RD COMMUNITY TRANSIT Geotech Report 2022-10-25
>
Address Records
>
W CASINO RD
>
2312
>
COMMUNITY TRANSIT
>
Geotech Report
>
2312 W CASINO RD COMMUNITY TRANSIT Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 2:05:32 PM
Creation date
5/9/2022 11:16:10 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2312
Tenant Name
COMMUNITY TRANSIT
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The proposed vault can be satisfactorily supported on the very dense glacial till encountered in our <br /> borings or on a minimum 2-foot thickness of structural fill. An allowable bearing pressure of 3,000 psf <br /> may be used in design of vault foundations supported on structural fill. This value can be increased to <br /> 8,000 psf where footings will be supported on undisturbed dense to very dense glacial till (anticipated <br /> below a depth of about 10 feet based on the 1979 as-built of the existing stormwater pipe and <br /> subsurface conditions encountered in boring B-3). We recommend placing a minimum 6-inch-thick <br /> layer of crushed rock beneath the vault slab to provide a level foundation and prevent disturbance of <br /> the subgrade. <br /> The effects of buoyancy under empty vault conditions should be considered in design. Buoyancy effects <br /> can be resisted by the weight of the concrete structure, the weight of zones of soils which are located <br /> above the slab floor which protrude beyond the walls, and soil friction along the sides of the walls. <br /> We recommend temporary cut slopes be inclined at 1H:1V (horizontal to vertical) or flatter depending <br /> on localized sloughing. Slope inclinations may need to be modified by the contractor if localized <br /> sloughing occurs. Steeper slopes up to 3/4H:1V may be feasible in the very dense glacial soils provided <br /> the geotechnical engineer confirms soil conditions are consistent and evaluates stability of the slopes <br /> during construction. <br /> ill The existing fill and native glacial till soils consist of moisture-sensitive silty soils that will become easily <br /> disturbed when wet. Re-use of the excavated soils will not be practical during wet weather or if the soils <br /> are more than about two points above the optimum moisture content. Based on the moisture content <br /> of the samples obtained in the borings, portions of the on-site soils may be suitable during dry weather <br /> provided they are properly conditioned. <br /> ri Perched groundwater was observed at 71/2 feet and 141/2 feet in boring B-3. Based on our experience, <br /> it is likely that utility excavations may be dewatered using a series of sumps and pumps from within the <br /> excavations. <br /> 4.1. Earthquake Engineering <br /> We evaluated the site for seismic hazards including liquefaction, lateral spreading, fault rupture and <br /> earthquake induced landsliding. Our evaluation indicates that the site does not have liquefiable soils <br /> present and therefore also has no risk of liquefaction induced lateral spreading. In addition, the site has a <br /> low risk of fault rupture and earthquake induced landsliding. <br /> 4.1.1.2015 IBC Seismic Design Information <br /> We recommend the following IBC 2015 parameters for Average Field Standard Penetration Resistance, <br /> Site Class,short-period spectral response acceleration(Ss), 1-second period spectral response acceleration <br /> (Si), and Seismic Coefficients FA and Fv. <br /> TABLE 1.2015 IBC SEISMIC PARAMETERS <br /> 2015 IBC Parameter Recommended Value <br /> Average Field Standard Penetration Resistance >50 <br /> Site Class C <br /> Short Period Spectral Response Acceleration,Ss(percent g) 144 <br /> 1-Second Period Spectral Response Acceleration,Si(percent g) 56 <br /> GEOENGINEERS_5 November 14,2019 Page 4 <br /> File No.2095-019-07 <br />