S <br /> E <br /> 6 I 5 13024 Beverly Park Rd, Ste 202 <br /> Mukilteo, WA 98275 <br /> www.AEGISengineering.com <br /> ENGINEERING phone (425)745-4700 <br /> fax (206)801-5797 <br /> March 14, 2019 <br /> Revised March 18, 2019 <br /> Via E-Mail: hodgesonhewitt@gmail.com <br /> New Hewitt/ Hodges Associates, LLC <br /> do Callie Alexander <br /> 2418-C California Street <br /> Everett, WA 98201 <br /> HODGES BUILDING—EVERETT,WA <br /> FLOOR/CEILING ASSEMBLIES <br /> Dear Ms. Alexander: <br /> AEGIS Engineering has been retained to provide fire protection engineering consulting <br /> regarding improvements at Hodges Building at 1804 Hewitt Avenue in Everett, <br /> Washington. The building is an existing 5-story residential structure. <br /> We understand the mechanical design involves exhaust fan ducts traveling up through <br /> the floor-ceiling assemblies. City of Everett is questioning whether the horizontal <br /> assemblies are smoke partitions or smoke barriers in accordance with applicable <br /> provisions of the IBC (2012 International Building Code as adopted and amended by <br /> State of Washington and City of Everett). <br /> Sections 710.2 and 710.4 of the IBC describe smoke partitions as walls. Therefore, the <br /> floor/ceiling assemblies in the Hodges Building are not smoke partitions. <br /> A fire-resistance rating is prescribed by IBC Sections 711.3 for horizontal assemblies <br /> separating fire areas and dwelling units. Section 711.9 states that penetrations and <br /> openings in horizontal assemblies shall be protected as required for smoke barriers only <br /> where required by other sections of the code. <br /> Section 420.3 of the IBC prescribes horizontal separation for Group R occupancies <br /> without prescribing the presence of smoke compartments or smoke barrier construction. <br /> Therefore, we conclude that horizontal assemblies at the Hodges Building do not <br /> involve smoke partitions or smoke barriers. <br /> Fire Protection • Building Code <br /> Consult • Design • En ineer <br />
The URL can be used to link to this page
Your browser does not support the video tag.