Laserfiche WebLink
S <br /> Meg Haley <br /> From: Meg Haley <br /> Sent: Monday,January 23, 2017 4:09 PM <br /> To: 'Impression Design'; 'briant@aegisengineering.com' <br /> Cc: Jim Venturo;Tony Lee <br /> Subject: RE: Letter of Recommendations for Fire Resistive Assemblies (Hodges) <br /> Hi Doug and Brian, <br /> The following minor comments may be more relevant to your architectural revisions. The fire-resistive <br /> construction revisions letter is a very well detailed letter and thank you both for that. The following comments <br /> also reflect the field visit that occurred this summer. <br /> City of Everett Comments <br /> • Please add current permit numbers for the proposed fire resistance design to the letter header: B1606- <br /> 032 and B1606-075. <br /> • The current configuration of the fire escape should be verified by a structural engineer to meet 100 psf, <br /> or propose revisions required to retrofit the structure. <br /> • The termination of the fire escape should be shown to meet the requirements IFC section 1104.16.6 <br /> and egress to the public way. <br /> • The elevator machine room should be shown to be 1 hour fire resistive construction on the floor and <br /> supporting construction down through the building, in addition to the walls. <br /> • The stairs to the elevator machine room and to the basement should be shown to have solid risers. <br /> • The basement stair should show that the crawl space is sealed from the stair and basement by one <br /> hour fire resistive construction. <br /> • The crawl space should be shown with insulation to meet current WSEC energy code requirements. <br /> • The tested fire resistive assemblies should be referenced AND shown on the revised drawings. <br /> Thanks again! <br /> Meg <br /> Meg H-ciLej, RA <br /> Plan Review Architect <br /> Permit Services,City of Everett <br /> 3200 Cedar St. <br /> Everett,WA 98201 <br /> Direct: 425-257-8813 <br /> Main: 425-257-8810(Option 8)Monday-rriday 7:30arn-12pm&1pm-4pm,except holidays <br /> everettwa.gov/permits <br /> everettwa.gov/codes <br /> everettwa.gov/maptools <br /> From: Impression Design [mailto:impressiondesignfthotmail.com] <br /> Sent: Friday, January 13, 2017 4:42 PM <br /> To: Meg Haley <br /> Cc: Jim Venturo <br /> Subject: Fw: Letter of Recommendations (Hodges) <br /> Hi Meg! <br /> Please find the attached letter from the fire protection engineer consultant regarding the Hodges <br /> Building. Can you and Jim please review said letter? If you approve the recommendations, I will implement <br /> them into the Drawings. We would like to move on this ASAP. <br /> lJ <br />